Use of a stainless steel mesh to exclude formosan subterranean termites
1997 - IRG/WP 97-10199
Physical barriers are gaining in popularity world-wide as methods of preventing subterranean termite penetration and attack on structures. Sized particle barriers of crushed basalt or granite are approved for use in building construction in Hawaii and Australia. TERMI-MESH, a marine grade 316 steel mesh, was recently developed in Australia and is approved there, and now in Hawaii, for use as a ter...
J K Grace, J R Yates III, C H M Tome, R J Oshiro


Using AE monitoring for detecting economically important species of termites in California
1991 - IRG/WP 2375
Acoustic emission (AE) monitoring was conducted on wooden samples containing three economically important species of termites in California (dampwood termite, Zootermopsis nevadensis, Western drywood termite, Incisitermes minor, and Western subterranean termite, Reticulitermes hesperus). Laboratory AE studies included varying termite species, as well as 7 day studies exploring the periodicity of t...
V R Lewis, R L Lemaster, F C Beall, D L Wood


Chemical evaluation of borate treated pine sapwood attacked by the subterranean termite Coptotermes acinaciformis
1993 - IRG/WP 93-20003
Sapwood of hoop (Araucaria cunninghamii Ait. ex D. Don) and slash (Pinus elliottii Englem.) pines were treated by Vacuum Pressure Impregnation (VPI) to provide test specimens. The concentration of boron was defined by chemical analyses of the timber, in the zone of primary attack by the termite being bioassayed. A common method of definition of preservative retention, weight uptake of preservative...
A R Moffat, B C Peters


A below-ground exposure method for determining the resistance of woody and non-woody materials to attack by subterranean termites
1993 - IRG/WP 93-10012
With existing field test procedures, in which specimens are installed vertically to some of their length into the ground and spaced out from each other ("grave-yard" tests), variations in the rate of contact by termites between replicates can be common. Mechanical damage to specimens during inspection and re-installation may also be difficult to avoid. A new field test method, evaluated in Austral...
M Lenz, J W Creffield


Comparison of three methods for assessing the in-ground termite resistance of treated timber, durable timber and plastics at sites in Australia, USA and Thailand - First results
1998 - IRG/WP 98-20132
The in-ground resistance of materials to attack by subterranean termites is most commonly assessed with one form or another of the conventional graveyard method, despite the significant shortcomings of this method. In Australia, an alternative method, in which all samples of test materials are placed below-ground, has been in use for more than 10 years. The method provides reliable exposure of sam...
M Lenz, A F Preston, J W Creffield, K J Archer, B M Kard, C Vongkaluang, Y Sornnuwat


A rapid method for collecting large numbers of subterranean termites from wood
1982 - IRG/WP 1165
A corrugated fiberboard trap is described which attracts large numbers of subterranean termites from infested logs. Single-trap collections in excess of 63 grams (wet wt.) for Reticulitermes virginicus (Banks) and 43 grams for Coptotermes formosanus Shiraki were taken one to three days following discovery by termites. If traps are removed from the source logs shortly after beeing attacked, termite...
J P La Fage, N-Y Su, M Jones, T Lawrence


Establishing standard principles for laboratory bioassays of termiticides with subterranean termites - progress, problems and prospects
1993 - IRG/WP 93-10013
Laboratory bioassays of termiticides, including wood preservatives, aim to give an indication of the likely concentrations effective in preventing damage to timber products and other materials in the field. In laboratory bioassays field conditions should be simulated as closely as possible. With a wide range of procedures in use around the world it may often be difficult to compare results between...
M Lenz, J W Creffield, Zhong Yun-hong, L R Miller


Options for termite management using the insect pathogenic fungus Metarhizium anisopliae
1996 - IRG/WP 96-10142
The insect pathogenic hyphomycete fungus Metarhizium anisopliae (Metschnikoff) Sorokin is promising as a biological insecticide for many species of subterranean termites. In Australia, a survey of termite mounds and feeding sites using a selective medium showed that this fungus is widespread but rarely causes mortality of termites under natural conditions. One isolate, codenamed FI610, has been se...
R J Milner, J A Staples, M Lenz


Variance in feeding on equivalent wood blocks by the Formosan subterranean termite (Coptotermes formosanus Shiraki)
1987 - IRG/WP 1325
We tested whether laboratory groups of Coptotermes formosanus Shiraki forage randomly when they are given 4 equivalent wood blocks, and whether group size affects variance of feeding on equivalent blocks. In all cases, foraging was not random, but, rather, the termites concentrated on a few preferred blocks. Group size did not affect this pattern of non-randomness. These data are useful for design...
J P La Fage, K S Delaplane


Bait box technique for remedial subterranean termite contro
1995 - IRG/WP 95-10115
The bait box technique, as described in this paper, was first used as a method to apply the dust toxicant, arsenic trioxide, to large numbers of aggregated subterranean termites. Over the last twelve years or so the technique has been refined, and in recent years, gained acceptance as an alternative subterranean termite control measure by members of the Australian pest control industry. This baiti...
J R J French, B M Ahmed, D M Ewart


Laboratory bioassays with termites – The importance of termite biology
2005 - IRG/WP 05-10550
Subterranean termites are frequently used in bioassays to asses the effectiveness of insecticides or the resistance of materials. Termites which appear to be vigorous with high inherent levels of activity are often relied upon, yet at the end of the experiments survival may be very unsatisfactory, even in the favourable environment of controls. Consequently, results from such bioassays may be mean...
M Lenz


Estimation of oral toxicity of boron as a bait toxicant and the trophallactic effects between individual members of termite colonies.
2003 - IRG/WP 03-10495
In recent years, because of the favourable environmental characteristics of boron, researchers in the wood preservation industries have refocussed on the use of boron as a major wood preservative against wood-destroying insects. Currently the greatest use of boron compounds is in remedial treatments. Boron has been found to have slow-acting toxicity against subterranean termites. Because of thi...
B M Ahmed


A field method for determining the above-ground resistance of wood and wood products to attack by subterranean termite
1994 - IRG/WP 94-20035
A method for determining the above-ground resistance of wood and wood products to subterranean termites in the field is described. Termites are aggregated in 20-litre steel drums, each containing a highly susceptible timber substrate. At the centre of each drum, specimens of the test material under evaluation are sandwiched, using circular sections of wire mesh, between two layers of the substrate...
J W Creffield


Resistance of wood inorganic material composites against decay fungi and subterranean termites
1996 - IRG/WP 96-40062
Double diffusion process was applied to the treatment of small sound sapwood specimens [20(T) x 20(R) x 10(L) mm³] of Cryptomeria japonica D. Don. The specimens were consecutively dipped in the two kinds of acqueous solutions to form water insoluble deposits within the wood after an expected reaction between the solutes. Following the comparison of deposits formed and treating conditions (tempera...
K Tsunoda, T Yoshimura, M Takahashi, S Hirao, H Usui


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Update
1994 - IRG/WP 94-20032
It was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthenate) against t...
J R J French


Performance of borate-treated sill plates (dodai) in a protected, above-ground field test in Japan
2002 - IRG/WP 02-30278
This document is supplemental to the previous IRG document (IRG/WP 2000-30239). An experiment to simulate the dodai (sill plate) of the Japanese houses was conducted at the termite field test site of the Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. DOT...
K Tsunoda, A Adachi, A Byrne, P I Morris, J K Grace


Termites in Uruguay; control, prevention and environment
1991 - IRG/WP 1474
When Prof. La Fage's questionaire on termites was received by 1987, few were aware of termite damage in Uruguay and infestations were not much reported. Further contacts between scientists, operators and homeowners, are now shaping the real threat of termite attack. Before letting the problem faIl in the hands of the layman, with all ist environmental risks, it seemed reasonable to: 1) re...
A Aber, G Baillod


Occurrence of termite species on decaying heartwood specimens exposed 18 to 23 years at an Australian site
1998 - IRG/WP 98-10270
The occurrence of species of subterranean termites on hardwood and softwood specimens (including preservative-treated), exposed in-ground at a semi-arid site at Walpeup (north-western Victoria), 18 to 23 years after installation, is reported. This paper presents maps of the cumulative occurrence on specimens, after six annual inspections, of the following species: Coptotermes acinaciformis, Hetero...
J W Creffield, J-D Thornton, G C Johnson


Proposing innovative technologies in the control of dry-wood insects
1985 - IRG/WP 1262
This paper discusses the social-economic problems involved in the biological evaluation of dry-wood insects with particular reference to Nigeria. It also discusses prospects of applying non-conventional methods of control against such insects, integrating these with the conventional preservatives as a control strategy. This discussion follows attempts made to identify the major dry-wood insects in...
M O Akanbi


Assessment of untreated Papua New Guinea timbers against subterranean termites. Final report
1993 - IRG/WP 93-10041
Four years after the exposure of eight timber species of varying density against subterranean termites in a field trial, Kwila was still generally sound while Taun, Malas and PNG Walnut were beginning to be attacked slightly to moderately. Calophyllum, Kamarere, PNG Beech and White Cheesewood were severely attacked and failed. Results after the period of exposure shows that Kwila rates highly as t...
H C Konabe, M Rokova


A preliminary assessment of the costs of termite activity in Australia: A discussion paper
1983 - IRG/WP 1207
A preliminary assessment has been made of the economic importance of termite activity in Australia and this paper is intended to serve as a starting point in discussing this topic. Damage to timber in service represents their greatest area of economic importance in urban and rural environments. Costs resulting from termite activity include timber replacements in buildings, railway sleepers, transm...
J R J French


Borate-treated food affects survival, vitamin B12 content, and digestive processes of subterranean termites
1990 - IRG/WP 1448
Toxicity of boron compounds was studied by analyzing survival rates and vitamin B12 contents in Formosan subterranean termites, Coptotermes formosanus Shiraki, that were exposed to dietary treatments for 10 days. The dietary treatments applied in moistened cellulose were (a) 0.05% boric acid equivalent (BAE) of disodium octaborate tetrahydrate, (b) 0.05% BAE of anmonium pentaborate plus sodium sul...
L H Williams, S I Sallay, J A Breznak


Subterranean termite attack potential in field test sites: assessment methods and field characterization
2003 - IRG/WP 03-10472
To assess subterranean termite attack potential in the field and seasonal variations, trials were set up in each of two managed silvicultural plantations, of Eucalyptus globulus and Pinus pinaster, respectively. Termite occupancy in lying dead wood was evaluated by an adaptation of the line-intersection method, and attack potential in soil was assessed by a system of stakes inserted into the groun...
T Nobre, L Nunes, L Brinca, D E Bignell


Termite resistance of Malaysian and exotic woods with plantation potential: Field evaluation
1998 - IRG/WP 98-10289
An in-ground resistance of selected Malaysian and exotic timbers to attack by a representative aggressive subterranean Coptotermes termite was evaluated as part of an on-going collaborative research between the Forest Research Institute of Malaysia and the University of Hawaii on termite control of building timbers under humid tropical conditions. A test site at FRIM, highly susceptible to the sub...
A H H Wong, J K Grace, L H Kirton


Field evaluation of the above-ground susceptibility of Pinus heartwood and untreated or treated sapwood to two species of Australian subterranean termites
1996 - IRG/WP 96-10147
Plantation-grown Pinus elliottii, Pinus caribaea and Pinus radiata specimens containing heartwood and untreated or preservative-treated sapwood were exposed above ground to the subterranean termites Coptotermes acinaciformis or Mastotermes darwiniensis near Sydney (NSW), Brisbane and Townsville (Qld), and Darwin (NT), using a variety of exposure techniques. Heartwood of Pinus elliottii and Pinus c...
M J Kennedy, J W Creffield, R H Eldridge, B C Peters