IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 663 documents. Displaying 25 entries per page.


Isolation and identification of the trail pheromone of the subterranean termite Reticulitermes speratus (Kolbe) (Isoptera: Rhinotermitidae)
1990 - IRG/WP 1459
The trail pheromone was successfully isolated from whole body extract of the termite Reticulitermes speratus (Kolbe) through various chromatographic reactions. Its trail-following activity was examined by bioassays. The primary structure of the pheromone was determined as normal chain dodecatrien-1-ol by capillary GC-MS analysis. Moreover, by means of capillary GC-MS and capillary GC-FTIR analyses...
M Tokoro, M Takahashi, R Yamaoka


Worker aggregation and baiting for management of subterranean termites
1994 - IRG/WP 94-10052
Environmental concern in the current use of cyclodiene and other chemicals for subterranean termite control had led to search of alternative environmental friendly management strategies. Worker aggregation and baiting are promising strategies. Aggregation is mediated through food recognition, attraction to some synthetic chemicals such as d-camphor, cinnamyl alcohol and sereral styryl compounds, s...
P K Sen-Sarma


Resistance of borate-treated lumber to subterranean termites in the field
1998 - IRG/WP 98-10255
Borate-treated wood samples were tested for their resistance against subterranean termites in the field. Wood samples (10.5x10.5x40cm3) of western hemlock were pressure impregnated with disodium octaborate tetrahydrate (DOT) and didecyldimethylammonium chloride (DDAC), and assigned into two groups on the basis of boron contents:high retention (1.5-2.2%BAE) and low retention(O.7~1.3%BAE). Eight rep...
K Tsunoda, A Adachi, T Yoshimura, A Byrne, P I Morris, J K Grace


Failure of overhead power transmission and telecommunication poles in Tanzania: Causes, preventive and remedial measures
1988 - IRG/WP 3465
Unless measures are considered urgently to combat massive pole failures occuring in service, it is likely that wooden poles may soon become unpopular. Consequently, pole users may be forced to use costlier alternatives such as underground cables and concrete or steel poles. In trying to countercheck this trend, this paper names the main agents of pole failure, discusses different models of pole fa...
K K Murira


Sulfluramid, a new bait concept for the control of termites
1995 - IRG/WP 95-30075
The annual cost of preventing, controlling and repairing the damage done by termites in the United States of America is in the billions of dollars. Current termite control methodology is generally effective in the control of termite activity. However, new technology (termite foams, termite baits, physical barriers) is emerging which has or will provide new tools to control termites. This report ce...
J B Ballard, T K Porter


Protection of buildings, other structures and materials in ground contact from attack by subterranean termites with a physical barrier - a fine mesh of high grade stainless stee
1993 - IRG/WP 93-10014
A new type of physical barrier for the prevention of attack by subterranean termites on buildings, other structures and materials in ground contact - a fine mesh of highalloy (originally 304, now 316) stainless steel - has recently been developed and patented worldwide by industry in Australia. The termite resistance of the material was assessed by CSIRO in laboratory and field trials. In the labo...
M Lenz, S Runko


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Second update
1995 - IRG/WP 95-10117
As was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthen...
J R J French


Depth of foraging of subterranean termites in tropical Australia
1996 - IRG/WP 96-10141
Stakes of radiata pine (Pinus radiata D.Don) of varying lengths to 800 mm were inserted vertically in the soil with all but their lower 100 mm sheathed in a capped UPVC tube representing a physical barrier to termites. In one series of trials, termites were encouraged to aggregate at the upper ends of the tubes, in order to determine whether they would descend to the lower end of the barrier. In a...
L R Miller, M Hoschke, M Neal


Controlled envelope treatments of Pinus sapwood, achieved by modifications to impregnation process and carrier solvents
2003 - IRG/WP 03-40258
Specimens of slash pine or radiata pine were treated to a target retention of 0.02% m/m permethrin with conventional light organic solvent fluids or with oil-modified fluids (Tanalith® T). Best achievable envelopes from LOSP fluids were poorly controlled, penetrating not only the target outer 0-5 mm zone (mean 0.019%, RSD 28%), but also breaking through into the 5-10 mm zone (mean 0.013%, RSD 37%...
M J Kennedy, P R S Cobham


Estimates of wood-consumption rates by termites
1983 - IRG/WP 1201
Effects of 2 components; termite-biomass and experiment duration on estimates of wood-consumption rates (mg wood/g termite/day), were examined. Three models; (1) no mortality, (2) linear mortality and (3) nonlinear mortality were used to calculate mean standing-crop biomass of termites. Model (1) predicted a significantly lower wood-consumption rate than those based on models (2) and (3). No signi...
N-Y Su, J P La Fage


Assessment of untreated Papua New Guinea timbers against subterranean termites. Progress report 2
1993 - IRG/WP 93-10040
Eight species of Papua New Guinea wood including Kwila (Intsia palembanica), Taun (Pometia pinnata), Malas (Homalium foetidum), PNG Walnut (Dracontomelon dao), Calophyllum (Calophyllum sp.), Kamarere (Eucalyptus deglupta), PNG Beech (Nothofagus spp.) and White Cheesewood (Alstonia scholaris) were exposed groun contact for their natural durability against subterranean termites. Inspection after 42 ...
M Rokova, H C Konabe


Evaluation of tropical wood by-products as a potential source for termite control products
2001 - IRG/WP 01-10408
Termites damaging in houses represent an ever growing threat in Europe, where the phenomenon has accelerated during the last ten years, as well as in the tropics, where infestations are permanent. To fight against this plague, the current methods used, through injection of organochloric or organophosphorized products into the timber structures and walls, are belonging to the past due to the toxici...
A Zaremski, S Robert, J-L Clement, D Fouquet


Remedial wood preservative efficacy of BORA-CARE against the Formosan subterranean termite and eastern subterranean termite (Isoptera: Rhinotermitidae)
1991 - IRG/WP 1504
When a spruce board (3.8 cm x 8.8 cm x 2.4 m) was surface-sprayed with BORA-CARETM solution (containing 23% disodium octaborate tetrahydrate) and stored in an air-conditioned room (24 ± 2°C and 60 ± 5% RH) for eight months, ca. 40% of the wood (measured by the cross section surface proportion) contained borates at the rate of >2,500 ppm BAE (boric acid equivalent). In a choice bioassay, term...
N-Y Su, R H Scheffrahn


Make ready of a detection system for insect attack by acoustical method
1996 - IRG/WP 96-10183
A contract CRAFT of European research allowed to build a detector prototype able to diagnose on site the presence of Hylotrupes bajulus and termites, even during the first stages of infestation when no sign of activity is visible. Based on non destructive control technics, the device picks up the acoustical waves emitted by the insects in the wood fibers. The amplification and the filtering of the...
M Hyvernaud, F Wiest, M-M Serment, M Angulo, O Winkel


Silafluofen: Novel chemistry and versatility for termite control
1995 - IRG/WP 95-30069
A novel silicon - containing insectizide, HOE 084498 ('Silafluofen'), with a favourable toxicological profile, has shown activity against a broad spectrum of agricultural and environmental health pests. Results from laboratory and field studies around the world have demonstrated that silafluofen is effective at protecting timber from attack by various species of termite and wood-...
A J Adams, A Jermannaud, M-M Serment


Preliminary tests on the effect of naturally occurring chemicals on termites
1983 - IRG/WP 1181
Twenty-eight naturally occurring chemicals consisting of monoterpenes, quinones and wood·extractives were tested against seven species of termite. Small pieces of filter pad and agathis wood chips measuring 5 mm by 10 mm were treated with the chemicals and exposed to the termites in polystyrene weighing bottles. Results of the tests revealed that the chemicals inhibited the feeding behaviour of t...
Nana Supriana


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Resistance of borate-treated lumber to subterranean termites under protected, above-ground conditions
2000 - IRG/WP 00-30239
An experiment to simulate the dodai (sill plate) of the Japanese houses was conducted at the termite field test site of Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. DOT(disodium octaborate tetrahydrate)-treated hem-fir samples [Tsuga heterophylla (Raf.)...
K Tsunoda, A Adachi, T Yoshimura, A Byrne, P I Morris, J K Grace


Principles behind the laboratory assessment of materials with subterranean termites - Recent perspectives and shifts in emphasis
1986 - IRG/WP 1291
Laboratory assessments of materials against termites aim to give an indication of the likely performance of materials in the field. To meet this objective, test procedures have to provide the conditions that promote the most vigorous activity of the insects. Implications of recent findings on inter- and intracolony variability in vigour, the need to monitor termite activity with differing types of...
M Lenz


Performance of Borate-Treated Wood Against Reticulitermes flavipes in Above-Ground Protected Conditions
2003 - IRG/WP 03-30309
Termites cause economically significant damage in Canada only in a few localized areas. However, one of those is in Canada’s largest city, Toronto, Ontario. In 1996, a test was set up of borate-treated lumber above ground, protected from rain but exposed to subterranean termites (Reticulitermes flavipes) in Kincardine Ontario. The material included western hemlock and amabilis fir lumber trea...
P I Morris, J K Grace, K Tsunoda, A Byrne


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


An overview of the economic importance and control of termites in plantation forestry and wood preservation in Peninsular Malaysia
2000 - IRG/WP 00-10382
Both the plantation forestry and wood preservation industries in the tropical and sub-tropical belts of the world, exemplified by the humid equatorial Peninsular Malaysia, regard termites as major destructive pests of standing trees, various timber products and building timber structures. This paper is a compilation of information on these economically important structural pests encountered in bot...
L G Kirton, A H H Wong, Kee Suan Cheok


The use of the Sentricon Termite Colony Elimination System for controlling termites in difficult control sites in Northern California
2000 - IRG/WP 00-10361
Some termite elimination trials in Northern California with the Sentricon Termite Colony Elimination System are presented - one of a large establish-ment, one of a single family residence with a long history of termite damage, one with a single family residence where other chemical treatments had repeatedly failed, and one single family residence in which the termites had not reached the house but...
D H Kistner, R J Sbragia


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


Nondestructive assessment of biodegradation in southern pine sapwood exposed to attack by natural populations of decay fungi and subterranean termites
1994 - IRG/WP 94-20042
Field methods for evaluating decay resistance of experimentally treated materials lack a means for quantitative measurement of residual strength. Quantitative relationships between speed of impact-induced waves travelling parallel to the grain and residual compressive strength have been demonstrated in softwood attacked by brown rot-decay fungi, but the effects of termites have not been documented...
R C De Groot, R J Ross, W Nelson


Previous Page | Next Page