IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 516 documents. Displaying 25 entries per page.


A behavioral assay for measuring feeding deterrency of a slow-acting biocide, A-9248, against the Formosan subterranean termite (Isoptera: Rhinotermitidae)
1988 - IRG/WP 1366
Concentration-dependent feeding deterrency of a slow-acting compound, A-9248 (diiodomethyl para-tolyl sulfone) was studied in a choice test against the Formosan subterranean termite, Coptotermes formosanus Shiraki. A-9248 was a feeding deterrent at concentrations ³8,000 ppm. Initially, Coptotermes formosanus fed on wood treated with 1,000-6,000 ppm A-9248 but learned to avoid the treatment as a r...
N-Y Su, R H Scheffrahn


Cuticular hydrocarbons for species determination of tropical termites
1990 - IRG/WP 1465
Insect species have unique mixtures of cuticular hydrocarbons in the protective wax of their integument. We use hydrocarbons to evaluate similarities among termite populations. Our assumption is that colonies with similar hydrocarbon profiles are closely related. We have collected Reticulitermes in California from areas suspected to have only Reticulitermes hesperus or Reticulitermes tibialis. The...
M I Haverty, M Page, B L Thorne, P Escoubas


Termites in Eastern Canada: A brief review and assessment
1987 - IRG/WP 1333
The distribution of termites in Canada is reviewed, with particular emphasis on the eastern subterranean termite Reticulitermes flavipes (Kollar) in Ontario province. Municipal and provincial termite control programs are discussed and current treatment practices are described. Previous research on Reticulitermes flavipes in Ontario is briefly reviewed, with reference to a number of unpublished rep...
J K Grace


European laboratory termite testing
1986 - IRG/WP 1299
As with all testing of wood preservatives the evaluation of the resistance to termites of treated wood requires methodology which is approriate to, and can be readily extrapolated to, the practical situation. Thus not only must the variations in possible treatment systems be taken into account (eg dip, brush or pressure application) so too must the range of termite species and the type of exposure...
R W Berry


Bioassays of extracts from scaly ash (Ganophyllum falcatum B1) against the subterranean termite Coptotermes acinaciformis (Froggatt)
1983 - IRG/WP 1206
Scaly ash, Ganophyllum falcatum B1. wood shavings were extracted by methanol, and fractionated with ethyl acetate, diethyl ether and water, and the anti-termitic properties of these materials bioassayed against the subterranean termite Coptotermes acinaciformis (Froggatt). Laboratory techniques were developed to overcome the problem of limited extractive materials. The results of the various bioas...
J R J French, J P Robinson, J W Creffield


The case for non-chemical termite barriers in termite control
1989 - IRG/WP 1381
A brief outline of current non-chemical barriers in subterranean termite control and their use in Australia is presented. Recent use of non-chemical barriers in Hawaii has led to their evaluation in termite control here and elsewhere. In Australia, preliminary laboratory and field experiments have shown similar results to those found against Coptotermes formosanus in Hawaii, namely, Australian Cop...
J R J French


The effectiveness of deltamethrin against subterranean termites (final report)
1993 - IRG/WP 93-30011
Two series of block tests of Pinus sp were treated by dipping them for 1 (one) minute in a solution with 0.015 (w/w) and 0.05 (w/w) of deltamethrin, respectively. In both cases, an average retention of 47 kg/m³ (0.32 l/m) was reached. One part of the block tests remained under laboratory conditions during 9 months, and the other was stored during equal period of time in a theater basement submitt...
P A Zanotto


International comparison of three field methods for assessing the in-ground termite resistance of materials - highlights after two years
1999 - IRG/WP 99-20157
First-year results of a comparative study, evaluating the in-ground termite resistance of a range of materials, including CCA and ACQ-treated timbers, using the below-ground exposure, ground contact and graveyard methods against diverse termite faunas were provided in IRG/WP/98-20132. Further annual inspections have confirmed early trends and identified notable differences between sites and method...
M Lenz, J W Creffield, A F Preston, B M Kard, C Vongkaluang, Y Sornnuwat


Tanalith T - a new preservative system for protecting house frames in Australia from termite attack.
2003 - IRG/WP 03-30306
The sawn timber industry in Australia has expressed a desire for a new low cost termite treatment. The treatment needs to be on-line in the dry mill, minimising material handling costs and with a very fast processing time to meet timber flow through the dry mill. The preservative, Tanalith® T, forms an envelope on both Pinus radiata and Pinus elliotti sawn timber. Field trials conducted in Aus...
P R S Cobham, J Snow


Use of a stainless steel mesh to exclude formosan subterranean termites
1997 - IRG/WP 97-10199
Physical barriers are gaining in popularity world-wide as methods of preventing subterranean termite penetration and attack on structures. Sized particle barriers of crushed basalt or granite are approved for use in building construction in Hawaii and Australia. TERMI-MESH, a marine grade 316 steel mesh, was recently developed in Australia and is approved there, and now in Hawaii, for use as a ter...
J K Grace, J R Yates III, C H M Tome, R J Oshiro


Further thoughts on standard principles of testing termiticides and/or wood preservatives
1992 - IRG/WP 92-1530
At the last annual meeting in Kyoto, Japan, there was a special session devoted to the standard principles of testing termiticides. There was definitely a perceived need by researchers and industry for some guidelines that spell out basic procedures required for any methodology in testing termiticidal formulations anywhere in the world. In the testing of new potential active ingredients, considera...
J R J French


Chemical evaluation of borate treated pine sapwood attacked by the subterranean termite Coptotermes acinaciformis
1993 - IRG/WP 93-20003
Sapwood of hoop (Araucaria cunninghamii Ait. ex D. Don) and slash (Pinus elliottii Englem.) pines were treated by Vacuum Pressure Impregnation (VPI) to provide test specimens. The concentration of boron was defined by chemical analyses of the timber, in the zone of primary attack by the termite being bioassayed. A common method of definition of preservative retention, weight uptake of preservative...
A R Moffat, B C Peters


A below-ground exposure method for determining the resistance of woody and non-woody materials to attack by subterranean termites
1993 - IRG/WP 93-10012
With existing field test procedures, in which specimens are installed vertically to some of their length into the ground and spaced out from each other ("grave-yard" tests), variations in the rate of contact by termites between replicates can be common. Mechanical damage to specimens during inspection and re-installation may also be difficult to avoid. A new field test method, evaluated in Austral...
M Lenz, J W Creffield


Comparison of three methods for assessing the in-ground termite resistance of treated timber, durable timber and plastics at sites in Australia, USA and Thailand - First results
1998 - IRG/WP 98-20132
The in-ground resistance of materials to attack by subterranean termites is most commonly assessed with one form or another of the conventional graveyard method, despite the significant shortcomings of this method. In Australia, an alternative method, in which all samples of test materials are placed below-ground, has been in use for more than 10 years. The method provides reliable exposure of sam...
M Lenz, A F Preston, J W Creffield, K J Archer, B M Kard, C Vongkaluang, Y Sornnuwat


Establishing standard principles for laboratory bioassays of termiticides with subterranean termites - progress, problems and prospects
1993 - IRG/WP 93-10013
Laboratory bioassays of termiticides, including wood preservatives, aim to give an indication of the likely concentrations effective in preventing damage to timber products and other materials in the field. In laboratory bioassays field conditions should be simulated as closely as possible. With a wide range of procedures in use around the world it may often be difficult to compare results between...
M Lenz, J W Creffield, Zhong Yun-hong, L R Miller


Variance in feeding on equivalent wood blocks by the Formosan subterranean termite (Coptotermes formosanus Shiraki)
1987 - IRG/WP 1325
We tested whether laboratory groups of Coptotermes formosanus Shiraki forage randomly when they are given 4 equivalent wood blocks, and whether group size affects variance of feeding on equivalent blocks. In all cases, foraging was not random, but, rather, the termites concentrated on a few preferred blocks. Group size did not affect this pattern of non-randomness. These data are useful for design...
J P La Fage, K S Delaplane


Bait box technique for remedial subterranean termite contro
1995 - IRG/WP 95-10115
The bait box technique, as described in this paper, was first used as a method to apply the dust toxicant, arsenic trioxide, to large numbers of aggregated subterranean termites. Over the last twelve years or so the technique has been refined, and in recent years, gained acceptance as an alternative subterranean termite control measure by members of the Australian pest control industry. This baiti...
J R J French, B M Ahmed, D M Ewart


Laboratory bioassays with termites – The importance of termite biology
2005 - IRG/WP 05-10550
Subterranean termites are frequently used in bioassays to asses the effectiveness of insecticides or the resistance of materials. Termites which appear to be vigorous with high inherent levels of activity are often relied upon, yet at the end of the experiments survival may be very unsatisfactory, even in the favourable environment of controls. Consequently, results from such bioassays may be mean...
M Lenz


Estimation of oral toxicity of boron as a bait toxicant and the trophallactic effects between individual members of termite colonies.
2003 - IRG/WP 03-10495
In recent years, because of the favourable environmental characteristics of boron, researchers in the wood preservation industries have refocussed on the use of boron as a major wood preservative against wood-destroying insects. Currently the greatest use of boron compounds is in remedial treatments. Boron has been found to have slow-acting toxicity against subterranean termites. Because of thi...
B M Ahmed


A field method for determining the above-ground resistance of wood and wood products to attack by subterranean termite
1994 - IRG/WP 94-20035
A method for determining the above-ground resistance of wood and wood products to subterranean termites in the field is described. Termites are aggregated in 20-litre steel drums, each containing a highly susceptible timber substrate. At the centre of each drum, specimens of the test material under evaluation are sandwiched, using circular sections of wire mesh, between two layers of the substrate...
J W Creffield


Laboratory evaluation of chlorothalonil against the Formosan subterannean termite
1992 - IRG/WP 92-1559
The fungicide chlorothalonil was evaluated as a wood preservative to prevent attack by the Formosan subterranean termite, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae). Southern yellow pine wafers treated with chlorothalonil (CTL) in P9 oil, CTL + chlorpyrifos in P9 oil, or CTL in xylene were conditioned by evaporative aging at 40° C for 4 weeks and exposed to termite attack in a mod...
J K Grace, P E Laks, R T Yamamoto


Control of the Formosan subterranean termite in China
1994 - IRG/WP 94-10088
The termite fauna of China comprises 44 genera of which approximately 481 species are described. The Formosan subterranean termite, Coptotermes formosanus Shiraki, is one of the most economically important species. Its distribution, the damage it causes, commercial preventive remedial measures in China, are briefly reviewed. Laboratory experiments utilizing either antibiotics or sodium borate on w...
Zhong Junhong, Liu Liling


Resistance of wood inorganic material composites against decay fungi and subterranean termites
1996 - IRG/WP 96-40062
Double diffusion process was applied to the treatment of small sound sapwood specimens [20(T) x 20(R) x 10(L) mm³] of Cryptomeria japonica D. Don. The specimens were consecutively dipped in the two kinds of acqueous solutions to form water insoluble deposits within the wood after an expected reaction between the solutes. Following the comparison of deposits formed and treating conditions (tempera...
K Tsunoda, T Yoshimura, M Takahashi, S Hirao, H Usui


An evaluation of the synthetic pyrethroid cypermethrin in organic solvent and emulsion formulations
1984 - IRG/WP 3290
The studies reported indicate that cypermethrin (NRDC 149) has considerable potential as an insecticide for wood preservatives. Cypermethrin appears to be about twice as effective as permethrin. The effectiveness of cypermethrin compared with g-HCH varies depending on the insect species, the phase of the life cycle and size of larva: for example, against mature Anobium larvae cypermethrin is appro...
S J Read, R W Berry


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Update
1994 - IRG/WP 94-20032
It was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthenate) against t...
J R J French


Previous Page | Next Page