IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 516 documents. Displaying 25 entries per page.


Performance of borate-treated sill plates (dodai) in a protected, above-ground field test in Japan
2002 - IRG/WP 02-30278
This document is supplemental to the previous IRG document (IRG/WP 2000-30239). An experiment to simulate the dodai (sill plate) of the Japanese houses was conducted at the termite field test site of the Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. DOT...
K Tsunoda, A Adachi, A Byrne, P I Morris, J K Grace


Occurrence of termite species on decaying heartwood specimens exposed 18 to 23 years at an Australian site
1998 - IRG/WP 98-10270
The occurrence of species of subterranean termites on hardwood and softwood specimens (including preservative-treated), exposed in-ground at a semi-arid site at Walpeup (north-western Victoria), 18 to 23 years after installation, is reported. This paper presents maps of the cumulative occurrence on specimens, after six annual inspections, of the following species: Coptotermes acinaciformis, Hetero...
J W Creffield, J-D Thornton, G C Johnson


Anti-feedant activity of stilbenic components from bark of Picea glehnii against a subterranean termite, Reticulitermes speratus
2002 - IRG/WP 02-10447
Stilbenic components, one of polyphenolic groups, widely distributed in plant bodies have been known as anti-microbial agents, but not known whether to have anti-termite activities. A stilbene glucoside, isorhapontin, from the bark of Picea glehnii was examined on the anti-feedant activity against a subterranean Reticulitermes speratus. Isorhapontigenin, the aglycone of isorhapontin, induced from ...
S Shibutani, M Samejima, S Doi


Assessment of untreated Papua New Guinea timbers against subterranean termites. Final report
1993 - IRG/WP 93-10041
Four years after the exposure of eight timber species of varying density against subterranean termites in a field trial, Kwila was still generally sound while Taun, Malas and PNG Walnut were beginning to be attacked slightly to moderately. Calophyllum, Kamarere, PNG Beech and White Cheesewood were severely attacked and failed. Results after the period of exposure shows that Kwila rates highly as t...
H C Konabe, M Rokova


Laboratory evaluation of copper naphthenate pressure treatments against the Formosan subterranean termite
1993 - IRG/WP 93-10005
Southern pine wafers and Douglas-fir cubes pressure treated with copper naphthenate in AWPA P9 Type A oil or in toluene were evaluated for resistance to attack by the Formosan subterranean termite, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae). Wood samples were pressure treated to target copper retentions of 0.040, 0.075, 0.095, or 0.150 pcf, conditioned to simulate field exposure, a...
J K Grace, R T Yamamoto, P E Laks


Laboratory termite testing of copper boron tebuconazole
2000 - IRG/WP 00-20192
The American Wood Preservers' Association laboratory choice and no choice termite test (AWPA E1-97) was performed on a formulation of copper azole, which is comprised of copper, boric acid, and tebuconazole. The formulation tested has a ratio of copper:boric acid:tebuconazole of 25:25:1. So as to examine the impact of leaching, the southern yellow pine wafers were treated with and without...
R F Fox, E A Pasek, J Patel


Termite resistance of Malaysian and exotic woods with plantation potential: Field evaluation
1998 - IRG/WP 98-10289
An in-ground resistance of selected Malaysian and exotic timbers to attack by a representative aggressive subterranean Coptotermes termite was evaluated as part of an on-going collaborative research between the Forest Research Institute of Malaysia and the University of Hawaii on termite control of building timbers under humid tropical conditions. A test site at FRIM, highly susceptible to the sub...
A H H Wong, J K Grace, L H Kirton


Field evaluation of the above-ground susceptibility of Pinus heartwood and untreated or treated sapwood to two species of Australian subterranean termites
1996 - IRG/WP 96-10147
Plantation-grown Pinus elliottii, Pinus caribaea and Pinus radiata specimens containing heartwood and untreated or preservative-treated sapwood were exposed above ground to the subterranean termites Coptotermes acinaciformis or Mastotermes darwiniensis near Sydney (NSW), Brisbane and Townsville (Qld), and Darwin (NT), using a variety of exposure techniques. Heartwood of Pinus elliottii and Pinus c...
M J Kennedy, J W Creffield, R H Eldridge, B C Peters


Worker aggregation and baiting for management of subterranean termites
1994 - IRG/WP 94-10052
Environmental concern in the current use of cyclodiene and other chemicals for subterranean termite control had led to search of alternative environmental friendly management strategies. Worker aggregation and baiting are promising strategies. Aggregation is mediated through food recognition, attraction to some synthetic chemicals such as d-camphor, cinnamyl alcohol and sereral styryl compounds, s...
P K Sen-Sarma


Resistance of borate-treated lumber to subterranean termites in the field
1998 - IRG/WP 98-10255
Borate-treated wood samples were tested for their resistance against subterranean termites in the field. Wood samples (10.5x10.5x40cm3) of western hemlock were pressure impregnated with disodium octaborate tetrahydrate (DOT) and didecyldimethylammonium chloride (DDAC), and assigned into two groups on the basis of boron contents:high retention (1.5-2.2%BAE) and low retention(O.7~1.3%BAE). Eight rep...
K Tsunoda, A Adachi, T Yoshimura, A Byrne, P I Morris, J K Grace


Protection of buildings, other structures and materials in ground contact from attack by subterranean termites with a physical barrier - a fine mesh of high grade stainless stee
1993 - IRG/WP 93-10014
A new type of physical barrier for the prevention of attack by subterranean termites on buildings, other structures and materials in ground contact - a fine mesh of highalloy (originally 304, now 316) stainless steel - has recently been developed and patented worldwide by industry in Australia. The termite resistance of the material was assessed by CSIRO in laboratory and field trials. In the labo...
M Lenz, S Runko


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Second update
1995 - IRG/WP 95-10117
As was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthen...
J R J French


Depth of foraging of subterranean termites in tropical Australia
1996 - IRG/WP 96-10141
Stakes of radiata pine (Pinus radiata D.Don) of varying lengths to 800 mm were inserted vertically in the soil with all but their lower 100 mm sheathed in a capped UPVC tube representing a physical barrier to termites. In one series of trials, termites were encouraged to aggregate at the upper ends of the tubes, in order to determine whether they would descend to the lower end of the barrier. In a...
L R Miller, M Hoschke, M Neal


Controlled envelope treatments of Pinus sapwood, achieved by modifications to impregnation process and carrier solvents
2003 - IRG/WP 03-40258
Specimens of slash pine or radiata pine were treated to a target retention of 0.02% m/m permethrin with conventional light organic solvent fluids or with oil-modified fluids (Tanalith® T). Best achievable envelopes from LOSP fluids were poorly controlled, penetrating not only the target outer 0-5 mm zone (mean 0.019%, RSD 28%), but also breaking through into the 5-10 mm zone (mean 0.013%, RSD 37%...
M J Kennedy, P R S Cobham


Estimates of wood-consumption rates by termites
1983 - IRG/WP 1201
Effects of 2 components; termite-biomass and experiment duration on estimates of wood-consumption rates (mg wood/g termite/day), were examined. Three models; (1) no mortality, (2) linear mortality and (3) nonlinear mortality were used to calculate mean standing-crop biomass of termites. Model (1) predicted a significantly lower wood-consumption rate than those based on models (2) and (3). No signi...
N-Y Su, J P La Fage


Assessment of untreated Papua New Guinea timbers against subterranean termites. Progress report 2
1993 - IRG/WP 93-10040
Eight species of Papua New Guinea wood including Kwila (Intsia palembanica), Taun (Pometia pinnata), Malas (Homalium foetidum), PNG Walnut (Dracontomelon dao), Calophyllum (Calophyllum sp.), Kamarere (Eucalyptus deglupta), PNG Beech (Nothofagus spp.) and White Cheesewood (Alstonia scholaris) were exposed groun contact for their natural durability against subterranean termites. Inspection after 42 ...
M Rokova, H C Konabe


Evaluation of tropical wood by-products as a potential source for termite control products
2001 - IRG/WP 01-10408
Termites damaging in houses represent an ever growing threat in Europe, where the phenomenon has accelerated during the last ten years, as well as in the tropics, where infestations are permanent. To fight against this plague, the current methods used, through injection of organochloric or organophosphorized products into the timber structures and walls, are belonging to the past due to the toxici...
A Zaremski, S Robert, J-L Clement, D Fouquet


Silafluofen: Novel chemistry and versatility for termite control
1995 - IRG/WP 95-30069
A novel silicon - containing insectizide, HOE 084498 ('Silafluofen'), with a favourable toxicological profile, has shown activity against a broad spectrum of agricultural and environmental health pests. Results from laboratory and field studies around the world have demonstrated that silafluofen is effective at protecting timber from attack by various species of termite and wood-...
A J Adams, A Jermannaud, M-M Serment


Preliminary tests on the effect of naturally occurring chemicals on termites
1983 - IRG/WP 1181
Twenty-eight naturally occurring chemicals consisting of monoterpenes, quinones and wood·extractives were tested against seven species of termite. Small pieces of filter pad and agathis wood chips measuring 5 mm by 10 mm were treated with the chemicals and exposed to the termites in polystyrene weighing bottles. Results of the tests revealed that the chemicals inhibited the feeding behaviour of t...
Nana Supriana


Termiticide degradation in Mississippi field tests
1994 - IRG/WP 94-30052
Degradation rates of some currently marketed United States termiticides are currently being studied. Separate quantities of soil were each treated at lowest label rates with termiticide, and placed in trenches along the inside and outside of concrete walls. Composite soil samples, each consisting of four soil cores, were collected after 1, 30, 60, 120, 180, 240, and 365 days, and again at 2 and 3 ...
B M Kard


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Resistance of borate-treated lumber to subterranean termites under protected, above-ground conditions
2000 - IRG/WP 00-30239
An experiment to simulate the dodai (sill plate) of the Japanese houses was conducted at the termite field test site of Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. DOT(disodium octaborate tetrahydrate)-treated hem-fir samples [Tsuga heterophylla (Raf.)...
K Tsunoda, A Adachi, T Yoshimura, A Byrne, P I Morris, J K Grace


Principles behind the laboratory assessment of materials with subterranean termites - Recent perspectives and shifts in emphasis
1986 - IRG/WP 1291
Laboratory assessments of materials against termites aim to give an indication of the likely performance of materials in the field. To meet this objective, test procedures have to provide the conditions that promote the most vigorous activity of the insects. Implications of recent findings on inter- and intracolony variability in vigour, the need to monitor termite activity with differing types of...
M Lenz


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


Previous Page | Next Page