Field Liners™ prevent creosote migration from transmission poles to soil during service
1996 - IRG/WP 96-40067
A full scale trial utilised 150 12m Eucalyptus grandis transmission poles treated with standard retentions of creosote according to SABS Method 457. One hundred poles had Field Liners™ applied while 50 did not. The 150 poles were used to complete an electricity transmission line in Southern KwaZulu-Natal. After 18 months service, incremental cores were taken from 15 cm below the ground lines of ...
M R Behr, G D Shelver, A A W Baecker


A comparison of the migration behaviour in soil of different waterborne wood preservatives and their leachates
1997 - IRG/WP 97-50091
Lysimeter tests were carried out on water-soluble wood preservatives and on wood preservative components leached out of impregnated wood. The purpose of these tests was to determine the extent to which the migration behaviour of environmentally relevant ions in the soil is influenced under comparable conditions. The results clearly show that the groundwater is especially at risk when wood preserva...
E Melcher, R-D Peek


The performance of metal-chromium-arsenic formulations after 32 to 38 years' in-ground exposure in Australia
2000 - IRG/WP 00-30240
Two trials of metal-chromium-arsenic preservatives were exposed in-ground in Australia. In Trial 1, Pinus radiata stakes treated with Boliden K.33, Boliden S.25, Celcure A, Tanalith C and Tanalith CA were installed at Sydney and Narrandera in 1961/1962. In Trial 2, P. radiata and Eucalyptus regnans sapwood were treated with Celcure A, Celcure A21-N, Celcure A 21-O and Tanalith CA (new) and install...
G C Johnson, J D Thornton, J Beesley


Wood surface pretreatments with metal tannates
1989 - IRG/WP 3552
The sequential application of aqueous solutions of tannins derived from radiata pine bark and water-soluble metal salts was examined as a means of improving the water repellency of wood surfaces. Nine metal salts were screened in combination with tannin solutions and, based on water repellency of pretreated filter paper, four were selected for further study. The two-step application of tannin solu...
D V Plackett, D R Cronshaw


Timber preservatives and corrosion
1983 - IRG/WP 3228
A survey of preservative treated timber commodities has illustrated problems that may be caused by corrosion. After treatment, timber should be compatible with commonly used fasteners. Whilst many corrosion methods have been used in the past, no standardized method is used by workers in timber preservation. The Queensland Department of Forestry is developing laboratory test methods for assessing c...
R I Davis


Environmental fate of copper-based wood preservatives in different soil substrates - Part 1: Screening of the metal adsorption potential
1998 - IRG/WP 98-50101-21 a
In treatment plants, spillage of wood preservatives onto soil may be of environmental concern. This potential soil contamination served as an objective for a screening study. Three different mineral soils, a mineral substrate and two horticultural substrates are examined for their sorptive potential of copper through mixing with wood preservative solutions. Depending on the soil/substrate charact...
G M F Van Eetvelde, J M Mwangi, F Tack, R Hartmann, M Stevens


Comparison of Temporal Changes in Metal Leaching and Aquatic Toxicity from Wood Treated with CCA and Alternative Preservatives
2005 - IRG/WP 05-50236
This study compares the temporal variation of chemical leaching and aquatic toxicity of wood treated with chromated copper arsenate (CCA) and other copper-based wood preservatives (alkaline copper quaternary (ACQ), copper boron azole (CBA), copper citrate (CC) and copper dimethyldithiocarbamate (CDDC)). Treated wood blocks were leached for 21 days and the leachate collected was analyzed for prese...
B Dubey, T G Townsend, G Bitton, H M Solo-Gabriele


Migration of chlorothalonil and carbendazim in fruits stored in wood treated with the anti-sapstain formulation Tuff Brite C
1997 - IRG/WP 97-50097
Fruits and vegetables stored in treated wood boxes are in contact with the products used for the treatment. In order to obtain regulatory approval for incidental food contact it is necessary to determine the quantity of residues on these fruits or vegetables. When the active materials are used in agriculture it is required that residues found are below to the MRL fixed for these substances. In the...
J F Cooper, D Riboul, M De Vleeschauwer, T L Woods


Detection of increased metal cations after wood decay using Chromeazurol-S
1997 - IRG/WP 97-20112
Chromeazurol-S (CAS) is a dye used for the spectrophotometric determination of metals, mainly aluminum (Al), berillium (Be) and copper (Cu). CAS has been widely used for determining the penetration of copper containing preservatives like CCA (AWPA A3-96). Additional uses include: i) detection of utility pole decay (Esyln, 1979), ii) a chemical spot test for aluminum in wood (Kukachka and Miller, 1...
F Green III, U Srinivasan, R B Miller


The growth and metal content of plants grown in soil contaminated by a copper/chrome/arsenic wood preservative
1977 - IRG/WP 3110
Salts of copper, chromium and arsenic are used together in water soluble formulations for the preservation of wood against insect and fungal attack. Copper/chrome/arsenic (CCA) preservatives are of proven efficacy and, used correctly, ensure a useful service life for timber for 30 years or more with little, if any, attendant threat to the environment from the treated wood itself. The preservative ...
C Grant, A J Dobbs


Metal plate fasteners in trussed rafters treated with preservatives or flame retardants - corrosion risks
1977 - IRG/WP 3104
In designing roof trusses employing metal plate fasteners it is generally assumed that the roof will remain dry in service. Whilst this is generally true, damp conditions do arise under some circumstances, although it is not possible to quantify the extent of the risk. It is only possible, therefore, to give general recommendations which must be interpreted in the light of local experience of serv...
R A Laidlaw, L C Pinion


Further steps in the development of above ground wood preservative systems
2002 - IRG/WP 02-30300
Metal and organo-metallic wood preservative systems have provided the consumer with cost effective wood preservative systems which satisfy the performance requirements in a wide range of end uses. With increasing environmental and legislative control, metal-free formulations have emerged as the dominant preservative systems for the protection of timber in the lower hazard classes. In higher ha...
P Warburton, A S Hughes


Evaluation of tropolone as a wood preservative : activity and mode of action
2002 - IRG/WP 02-30282
The fungicidal activity of 2-hydroxy cyclohepta-2,4,6-trienone (tropolone) analogue of b-thujaplicin a natural product responsible for the durability of heart wood of several cupressaceous trees was investigated in vitro on growth of white and brown rot fungi. Results obtained show that tropolone, easily prepared from commercially available products, possesses strong fungicidal activity similar ...
P Gérardin, M Baya, N Delbarre, P N Diouf, D Perrin, P Soulounganga, E Gelhaye, J P Jacquot, C Rapin


Treatment of wood by diffusion of salts
1976 - IRG/WP 368
A brief survey is given on the treatment of wood by diffusion of salts. The compounds used for this process, mainly boron and fluorine compounds, are mentioned and the factors influencing diffusion described. The main pre-condition is a high moisture content of the wood of above 40%. Fields of application are fresh roundwood, remedial treatment of poles and sleepers, preservation of posts and espe...
G Becker


Effect of wrapping on movement of chloropicrin, Vapam, and Vanicide TH in southern pine timbers
1987 - IRG/WP 3411
Important fungi that decay wood protucts were "inoculated" into nonpressure-treated southern pine timbers as vapor-sensing agents to evaluate the effect of wrapping on the movement and persistence of fungitoxic concentrations of chloropicrin, Vapam, and Vanicide TH in the timbers. Fumigant movement and persistence in the timbers was enhanced by wrapping the timbers in polyethylene after fumigation...
T L Highley


A technique for measuring preservative loss or redistribution during leaching
1983 - IRG/WP 2199
Radiata pine sapwood stakes were treated with benzalkonium chloride (AAC) or copper-chrome-arsenate (CCA). After fixation and drying the outer 2 mm and 2-4 mm layers were removed from one radial longitudinal face. The planed face was coated with a waterproof coating and AAC-treated stakes were leached for 6, 12 or 18 weeks; 12 weeks for the CCA-treated stakes. After airdrying three 2 mm layers (0-...
J A Drysdale


The movement of iron into field test stakes
1987 - IRG/WP 2284
Failed and sacrificial stakes recovered from the Westham Island field test site were examined for their iron content. Varying amounts were recorded, which were greatest in the failed stakes. The possible role of the iron taken up by the below ground portion of the stakes, in accelerating the decay process and/or the preservative leaching is under investigation. The reaction of the iron with the ch...
J N R Ruddick, P I Morris


Effect of leaching temperature and water acidity on the loss of metal elements from CCA treated timber in aquatic applications. Part 1: Laboratory scale investigation
1995 - IRG/WP 95-50046
In order to investigate the applicability of current prestandard leaching test methods, a series of experiments has been performed on CCA impregnated wood dealing with the influence of pH, temperature and agitation of the surrounding water. The leaching method used in this first part of the investigation is the European prestandard drafted by CEN/TC38/WG11, a short term dynamic leaching test under...
G M F Van Eetvelde, R J Orsler, G E Holland, M Stevens


Quantification of creosote migration down wooden poles and the prevention of its depletion during flood irrigation
1994 - IRG/WP 94-50032
Polyethylene field liners heat-shrunk onto soil-contact surfaces prevented decay of creosote-treated Eucalyptus grandis vineyard poles under flood-irrigation. The present work quantified losses of creosote from these poles after six and 24 months' service. After six months' service the mean creosote retention of unlined poles above the ground line was 12.62% (m/m dry wood), with ...
M Behr, A A W Baecker


Movement of chloropicrin, Vapam, and methylisothiocyanate in southern pine and Douglas fir timbers
1987 - IRG/WP 3410
Douglas fir and southern pine timbers, 15.2 x 15.2 x 426 cm³ (6-in x 6-in x 14-ft), were "inoculated" with brown-rot and white-rot fungi as vapor-sensing agents to evaluate the movement and distribution of fungitoxic concentrations of chloropicrin, Vapam, and methylisothiocyanate (MIT) over a 20-week period. Residual fumigant in timbers was determined by a bioassay with Gloeophyllum trabeum. The ...
T L Highley


Bethoguard; A new wood protecting fungicide for use in metal free ground contact wood preservatives
2002 - IRG/WP 02-30301
Research has identified the limitations in both the spectrum of activity and permanence of organic biocides placed in wood in high hazard environments, particularly in the absence of heavy metals such as copper. More specifically, the control of soft rot decay in wood in soil contact has proven to be most problematic. The new organic biocide, Bethoguard; an oxathiazine, has demonstrated excellen...
S C Forster, G R Williams, M Van Der Flaas, M Bacon, J Gors


PXTS; A Metal Free Oligomer Wood Preserving System - A Summary of Data To Date
2004 - IRG/WP 04-30350
The world is continually looking for new wood preservative technology, especially to address environmental concerns. Recent changes in the USA have limited the use of arsenical containing formulations to industrial use through a negotiated voluntary cancellation of most residential label uses. PXTS (Polymeric Alkylphenol Polysulfide) offers a brand new technology that is an all organic system, lik...
M H Freeman, D D Nicholas, D Renz, R Buff


Fungal degradation of wood treated with metal-based preservatives. Part 1: Fungal tolerance
1996 - IRG/WP 96-10163
In recent years, concerns have arisen about the leaching of heavy metals from wood treated with chromated copper arsenate (CCA), particularly because of the large amount of CCA treated wood that will be discarded in the coming years. The long term objectives of this work are to determine the fate of copper, chromium and arsenic with the aging and potential decay of CCA-treated wood, and to develop...
B Illman, T L Highley


Corrosiveness of metal by copper-based preservatives
2006 - IRG/WP 06-40329
The corrosive rates of 4 types of metal as well as epoxy-coated metal by a variety of preservatives derived from different copper source and ingredients were conducted in this paper. The main results shown that: CCA is less corrosive to red brass and Q235A steel than other copper formulations; Copper-based preservatives such as ACQ and copper azole derived from basic cupric carbonate or cupric hyd...
Ying Zhang, Mingliang Jiang


Corrosion of metal fasteners in contact with copper preservative treated wood
2007 - IRG/WP 07-20370
The corrosion rates of metal fasteners in contact with alkaline copper quat (ACQ) treated wood with or without commercially available water repellent was compared to that of cedar. In this experiment, fasteners were sandwiched between two pieces of treated wood and exposed to a humid environment at a slightly elevated temperature. The use of a “sandwich” design allowed periodic examination of ...
BaekYong Choi, J N R Ruddick