IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 159 documents. Displaying 25 entries per page.


Comparison of methods for monitoring CCA fixation
1994 - IRG/WP 94-40023
The CCA fixation status in the outer 12.5 mm of pole sections of southern pine (Pinus sp.), red pine (Pinus resinosa) and lodgepole pine (Pinus contorta var. latifolia) were followed during fixation at 21°C under non-drying conditions by the following procedures: - Qualitative CrVI indication by the chromotropic acid spot test. - Quantitative CrVI in the expressate by the diphenylcarbazide method...
P A Cooper, Y T Ung, G Zanjani


A comparison of the migration behaviour in soil of different waterborne wood preservatives and their leachates
1997 - IRG/WP 97-50091
Lysimeter tests were carried out on water-soluble wood preservatives and on wood preservative components leached out of impregnated wood. The purpose of these tests was to determine the extent to which the migration behaviour of environmentally relevant ions in the soil is influenced under comparable conditions. The results clearly show that the groundwater is especially at risk when wood preserva...
E Melcher, R-D Peek


Permanence of permethrin and bifenthrin in framing timbers subjected to hazard class 3 exposure
2005 - IRG/WP 05-30383
End-sealed Pinus radiata specimens measuring 235 x 90 x 35 mm were treated using a modified Lowry schedule with permethrin or bifenthrin in white spirit to Hazard Class 2 (H2) retentions. After conditioning, the specimens were exposed at 45o on north facing racks near Melbourne (Australia). Samples of the specimens were taken before installation, and after three and six months exposure. Analyses o...
A C Hunt, D G Humphrey, R Wearne, L J Cookson


Comparison between two laboratory test methods for determining the effectiveness on wood preservatives against blue stain in fresh wood
1987 - IRG/WP 2289
Most of the work done on determination of the effectiveness of new formulae for treating fresh wood against blue stain have been focussed on their use in the manufacture of saw timber. This work explains two laboratory methods, one which simulates the working and climatological conditions of factories making packages for fruit and vegetables in the Spanish Levante, showing that contamination of wo...
A M Navarrete, M T De Troya


A preliminary comparison of GC, HPLC and ELISA analysis of resin acids in pulp mill effluents
1997 - IRG/WP 97-20120
Resin acids are naturally occurring diterpenoid carboxylic acids present in most Canadian softwoods. There are eight common resin acids that are classified into two groups; the abietanes and the pimaranes. During processing of wood products they can be released into the environment where they are of concern because of their acute toxicity toward fish and other aquatic life. Traditionally resin aci...
A N Serreqi, K Stark, Xiumei Feng, J N Saddler, C Breuil


Comparison of performance of wood preservatives in laboratory and field tests of treated commodities
1993 - IRG/WP 93-20010
The purpose of laboratory tests for evaluating efficacy of wood preservatives is usually to establish toxic values against standard strains of wood decay fungi. Exposure conditions are usually chosen as optimal for fungal growth. Toxic values so determined serve as a guide as to expected performance of the preservative in field stake tests or in above ground exposure tests. Test material is select...
M E Hedley


Comparison of variable, constant and fluctuating pressure methods
2001 - IRG/WP 01-40212
The objective of this work was to evaluate potential improvements in pressure treatment arising from the use of a control valve. A constant pressure of 1035 kPa was compared to the conventional variable pressure method where the pressure is allowed to drop to 860 kPa as the solution is absorbed by the wood. A fluctuating pressure method (FPM) where the pressure cycles between 1000 and 1070 kPa was...
S M McFarling, P I Morris


Comparison of the FRIM and forest research laboratory methods for screening of anti-sapstain formulations
1999 - IRG/WP 99-20170
Two laboratory methods for screening of anti-sapstain formulations were compared. The method adopted by the Forest Research Institute Malaysia (FRIM) involved 3 weeks assessment of rubberwood (Hevea brasiliensis) blocks, dipped in the candidate formulation and inoculated with mycelial/spore suspension of sapstain (Botryodiplodia theobromae) or decay (Schizophyllum commune) fungi, and incubated on ...
A H H Wong, D R Eden, C M Chittenden, M E Hedley, R N Wakeling


Leaching of active components from preservative-treated timber. Stages 2 & 3: Laboratory testing and comparison with semi-field testing
2004 - IRG/WP 04-20303
This part of the project is focussed on leaching from preservative-treated wood obtained by the laboratory test method CEN/OECD draft guideline, February 2003 ”OECD guideline for the testing of chemicals proposal for new guideline XXX. Estimation of Emissions from Preservative-treated Wood to the Environment: Laboratory Method for wood held in the storage yard after treatment and for wooden comm...
N Morsing, B Lindegaard


A comparison between high and conventional incision densities for improving preservative treatment of Douglas-fir heartwood lumber
1993 - IRG/WP 93-40009
Incising is required for the preservative treatment of most wood species from the western United States; however, there is considerable debate about the density of incisions required to achieve adequate treatment. Previous studies have shown that the incision effect on treatment is relatively narrow, suggesting that incision densities should be significantly increased over current practices and st...
S T Lebow, J J Morrell


Clean creosote - its development, and comparison with conventional high temperature creosote
1983 - IRG/WP 3235
Pigment emulsified creosote (PEC) is presently being tested and shows considerable stability in terms of water content, pigment level, pH, viscosity, rheological behaviour and microscopy. Timber samples from several eucalypt species have been treated with PEC and side matched samples treated with conventional high temperature creosote (HTC). The PEC treated specimens showed higher weight retention...
C W Chin, J B Watkins, H Greaves


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Second update
1995 - IRG/WP 95-10117
As was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthen...
J R J French


Leaching from CCA-treated wood submerged in seawater: Effect of high loadings, and a comparison between laboratory and marine conditions
1996 - IRG/WP 96-50080
This study of leaching examined the following variables: CCA loading; marine versus laboratory exposure and length of submergence. Blocks of Pinus sylvestris were treated to a range of nominal retentions from 15 to 50 kg/m³. Each block was then divided into three cubes and all transverse faces were sealed. All cubes were allowed to fix at ambient temperature for a minimum of one week. One set of ...
R M Albuquerque, S M Cragg, J D Icely


Comparison of two laboratory methods for screening potential anti-sapstain chemicals
1993 - IRG/WP 93-10036
Two methods were used to screen a number of potential anti-sapstain chemicals in the laboratory. In one method miniature boards of freshly felled Scots pine sapwood were dip treated with the candidate chemical, sprayed with a suspension of stainers or moulds and incubated for five weeks. In the other method antibiotic assay discs were treated with precise quantities of chemical, plated out on malt...
S M Gray, D J Dickinson


Screening wood preservatives: Comparison of the soil block, agar block and agar plate tests
1993 - IRG/WP 93-20001
Several test procedures have been developed over the years to screen potential biocides for their value as wood preservatives. Each test has inherent advantages and disadvantages. In this paper the relative merits of the soil block, agar block and agar plate tests are compared. Eight commercially available biocides encompassing inorganic and organic systems were tested against four basidiomycete d...
K J Archer, D D Nicholas, T Schultz


Comparison of the in-ground performance of pigment emulsified creosote (PEC) and high temperature creosote (HTC)
2000 - IRG/WP 00-30217
A long-term field trial was conducted in Australia to compare the in-ground performance of two oil-borne preservative formulations, conventional high temperature creosote (HTC) and a modified creosote formulation, pigment emulsified creosote (PEC). Three retentions (50, 100 and 200 kg/m³) were targeted for each formulation. An additional retention of PEC formulation (308 kg/m³), which contained ...
J W Creffield, H Greaves, N Chew, N K Nguyen


Comparison of Temporal Changes in Metal Leaching and Aquatic Toxicity from Wood Treated with CCA and Alternative Preservatives
2005 - IRG/WP 05-50236
This study compares the temporal variation of chemical leaching and aquatic toxicity of wood treated with chromated copper arsenate (CCA) and other copper-based wood preservatives (alkaline copper quaternary (ACQ), copper boron azole (CBA), copper citrate (CC) and copper dimethyldithiocarbamate (CDDC)). Treated wood blocks were leached for 21 days and the leachate collected was analyzed for prese...
B Dubey, T G Townsend, G Bitton, H M Solo-Gabriele


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Comparison of the inhibitory effects of borate, germanate, tellurate, arsenite and arsenate on 6-phosphogluconate dehydrogenase
1991 - IRG/WP 1508
Sodium borate inhibits the enzymatic activity of many dehydrogenases, and it is thought that this is due to the complexation of the borate anion with the coenzyme nucleotide. It has been suggested in the past that complexation of this type, leading to enzyme inhibition and other biological effects, is responsible for the inhibition of fungal growth and consequently the protection of boron treated ...
J D Lloyd, D J Dickinson


A comparison of analytical techniques
1995 - IRG/WP 95-20061
This paper compares carefully-controlled weight retentions and analysis by XRF, ICP, combustion methods and a new extraction procedure for the new preservative, Copper(II) Dimethyldithiocarbamate (CDDC). Various experimental parameters such as particle size and drying conditions were investigated. In general, the correlations between and among the procedures are very high. The extraction-colorimet...
A C Gallacher, C R McIntyre, M H Freeman, D K Stokes, W B Smith


Comparison of permethrin and fenvalerate as termiticides and their significance to Australian Quarantine Regulations
1984 - IRG/WP 1230
This paper reports detailed laboratory evaluations of the termiticidal efficacy of permethrin and fenvalerate-treated wood blocks. Comparison between artificially wheathered permethrin-treated blocks and unweathered blocks is given. The effect of a 6-week soil burial period on pyrethroid-treated blocks at a retention of 0.08 kg/m³ is also reported. Toxic or protection threshold values for the two...
J W Creffield, C D Howick


Comparison of the anti-fungal efficacy of Cobra with drill perforation on oscillating pressure treated spruce transmission poles -Laboratory test
1988 - IRG/WP 3469
A laboratory method for measuring the depth of penetration of the fungicidal concentrations effective against basidiomycetes (brown rot) was developed. The tests on CCB oscillating pressure treated spruce transmission poles have shown that the depth of salt penetration can be increased by about 10 mm by a drill perforation before the impregnation. An even better penetration is reached, however, if...
E Graf, B Zgraggen


Comparison of thermally modified wood originating from four industrial scale processes – durability
2002 - IRG/WP 02-40229
This study examined the differences in biological wood properties of heat treated wood originating from four different European industrial heat treatment plants. The manufacturers of heat treated material were: PLATO Hout B.V./Netherlands, Thermo Wood/Finland, New Option Wood/France and Menz Holz/Germany where Oil-Heat treated Wood (OHT) is produced. The results of miniblock tests with basidiomyc...
C R Welzbacher, A O Rapp


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


A comparison of the leaching resistance of copper 2-ethanolamine and copper ethylenediamine treated Scots pine
2000 - IRG/WP 00-30233
The depletion of copper from copper 2-ethanolamine and copper ethylenediamine treated Scots pine blocks was investigated. A greater leaching resistance was found for copper 2-ethanolamine, which retained ca. 86% and ca. 50% copper after water and buffer leaching, respectively. Leached amine treated blocks also contained significant residual amine. This was consistent with other observations linked...
Xiao Jiang, J N R Ruddick


Previous Page | Next Page