IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 523 documents. Displaying 25 entries per page.


Resistance of two commercial cement-bonded rubberwood particle composites to decay and termites
2000 - IRG/WP 00-10338
Two types of cement-bonded rubberwood (Hevea brasiliensis) particle composites (tradenames: Cemboard and Primaflex in Malaysia), were evaluated for termite resistance (prevalent termite: Coptotermes curvignathus) in the field, and decay resistance (test white rot fungi: Schizophyllum commune and Pycnoporus sanguineus; test brown rot fungus: Gloeophyllum trabeum; test soft rot fungi: Phialophora fa...
A A H Wong


A study on the effectiveness of didecyldimethylammonium chloride to protect wood from attack by termites
1993 - IRG/WP 93-30009
A laboratory bioassay was conducted on the ability of didecyldimethylammonium chloride (DDAC) to protect Pinus radiata D.Don wood specimens from attack by two of Australia's most economically important species of subterranean termite, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Sapwood specimens of Pinus radiata, treated to achieve nominal retentions of 0.5...
J W Creffield


Silicic acid-Boric acid complexes as wood preservatives
2001 - IRG/WP 01-30273
A silicic acid monomer aqueous solution (SAMS) or colloidal silicic acid solution (CSAS) was combined with various metal compounds or boric acid. Agents where SAMS or CSAS was combined with boric acid gave good protection against decay caused by the brown-rot fungus Fomitopsis palustris, the treated wood (Cryptomera japonica D. Don) specimens after the leaching test maintained a high resistance to...
H Yamaguchi


Preference of swarming termites for various colored lights
1984 - IRG/WP 1238
The ability of the alates of the drywood termite Bifiditermes beesoni (Gardner) to discriminate ten different colored lights was studied. When an alternative choice of any of two colors was offered, the light-blue was preferred to all other tested colors by 97.7% of the alates. A lower degree of attractivity was found for some other colors and certain other colors were indistinguishable. Furthermo...
M Afzal


Comparison of the in-ground performance of pigment emulsified creosote (PEC) and high temperature creosote (HTC)
2000 - IRG/WP 00-30217
A long-term field trial was conducted in Australia to compare the in-ground performance of two oil-borne preservative formulations, conventional high temperature creosote (HTC) and a modified creosote formulation, pigment emulsified creosote (PEC). Three retentions (50, 100 and 200 kg/m³) were targeted for each formulation. An additional retention of PEC formulation (308 kg/m³), which contained ...
J W Creffield, H Greaves, N Chew, N K Nguyen


Termatrac: microwave technology for non-destructive detection of insect pests in timber
2002 - IRG/WP 02-20253
Termatrac is a microwave instrument that has been developed in Australia to detect termite movement within timber and wall cavities. We present data from an investigation into the usefulness of the instrument in detecting drywood and subterranean termites in timber. The West Indian drywood termite Cryptotermes brevis (Walker) was detected in a wooden chair. The subterranean termites Coptotermes ac...
B C Peters, J W Creffield


The efficacy of preservatives into the glue-line of plywood
1993 - IRG/WP 93-30002
This research is anti-termite/decay preservatives mixed with resin to produce the plywood. Thereafter, anti-decay/termite plywood were produced by the ordinary methods. To produce suitable plywood in the utilization and certified performance, the preservatives should be 0.3 to 0.4 kg/m³ of Chlorpyrifos; 0.88 and 1.10 kg/m³ of mix preservatives of Chlorpyrifos + IF-1000. Laboratories decay test (...
S Fushiki, T Saito, Y Katuzawa, Y Imamura, S Yusuf, B Subiyanto


Principles behind the laboratory assessment of materials with subterranean termites - Recent perspectives and shifts in emphasis
1986 - IRG/WP 1291
Laboratory assessments of materials against termites aim to give an indication of the likely performance of materials in the field. To meet this objective, test procedures have to provide the conditions that promote the most vigorous activity of the insects. Implications of recent findings on inter- and intracolony variability in vigour, the need to monitor termite activity with differing types of...
M Lenz


Termite likes steamed larch wood
1995 - IRG/WP 95-10113
Steamed wood of Japanese larch (Larix leptolepis (Sieb. et Zucc.) Gord.) was preferably attacked by termites. Steam treatments have often been applied to Japanese larch wood for improving its penetrability or color. For preventing termite attack on steamed timber, we have to elucidate why termite likes it. Choice tests with Coptotermes formosanus Shiraki were conducted using larch boards steamed f...
S Doi, M Kubota, M Takahashi, T Yoshimura, A Adachi


Performance of Borate-Treated Wood Against Reticulitermes flavipes in Above-Ground Protected Conditions
2003 - IRG/WP 03-30309
Termites cause economically significant damage in Canada only in a few localized areas. However, one of those is in Canada’s largest city, Toronto, Ontario. In 1996, a test was set up of borate-treated lumber above ground, protected from rain but exposed to subterranean termites (Reticulitermes flavipes) in Kincardine Ontario. The material included western hemlock and amabilis fir lumber trea...
P I Morris, J K Grace, K Tsunoda, A Byrne


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Assessment of the Termatrac™ system - a new microwave based technology for non-destructive detection of termites
2003 - IRG/WP 03-20265
Termites can be difficult to detect reliably and many detection methods are destructive to property or disturbing to the termites (which may interfere with remedial treatment). The reliability of Termatrac™, a new Australian device for the detection of termites in an unobtrusive manner, based on novel microwave technology, was tested in the field. Termite presence was assessed as indicated by th...
T A Evans


A case for ecosystem-level experimentation - A discussion paper
1986 - IRG/WP 1296
Although laboratory bioassays provide a first step in testing for potential termiticides and assist in formulating recommendations of these chemicals for regulatory agencies and users, they are not designed for predicting effects on natural populations (including humans) and on ecosystem-level features. To overcome this we need microcosm studies, carefully controlled experimental manipulations of ...
J R J French


Comparison of permethrin and fenvalerate as termiticides and their significance to Australian Quarantine Regulations
1984 - IRG/WP 1230
This paper reports detailed laboratory evaluations of the termiticidal efficacy of permethrin and fenvalerate-treated wood blocks. Comparison between artificially wheathered permethrin-treated blocks and unweathered blocks is given. The effect of a 6-week soil burial period on pyrethroid-treated blocks at a retention of 0.08 kg/m³ is also reported. Toxic or protection threshold values for the two...
J W Creffield, C D Howick


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


An overview of the economic importance and control of termites in plantation forestry and wood preservation in Peninsular Malaysia
2000 - IRG/WP 00-10382
Both the plantation forestry and wood preservation industries in the tropical and sub-tropical belts of the world, exemplified by the humid equatorial Peninsular Malaysia, regard termites as major destructive pests of standing trees, various timber products and building timber structures. This paper is a compilation of information on these economically important structural pests encountered in bot...
L G Kirton, A H H Wong, Kee Suan Cheok


The use of the Sentricon Termite Colony Elimination System for controlling termites in difficult control sites in Northern California
2000 - IRG/WP 00-10361
Some termite elimination trials in Northern California with the Sentricon Termite Colony Elimination System are presented - one of a large establish-ment, one of a single family residence with a long history of termite damage, one with a single family residence where other chemical treatments had repeatedly failed, and one single family residence in which the termites had not reached the house but...
D H Kistner, R J Sbragia


CCFZ, a new type of water-borne wood preservative for vacuum pressure impregnation
1991 - IRG/WP 3643
By combination of CCF-Salt types with zinchexafluorosilicate a remarkable improvement of efficacy is achieved. In the same time the ecotoxicoligical data become more save. As well as the efficacy against wood-destroying organisms (Basidiomycetes, Soft rot and Long horn beetle) the basic data to evaluate the ecotoxicological behaviour of a CCFZ-Salt are described and compared with the properties of...
W Metzner, D Seepe, H-W Wegen


Variable chlordane residues in soil surrounding houses in Louisiana
1989 - IRG/WP 1404
Eight soil samples from each of 30 houses in greater New Orleans, Louisiana were collected in October, 1986 and analyzed for chlordane residues (ppm). All houses had reportedly been treated in the late 1960's or early 1970's. Chlordane occurred in all samples, and the overall mean (+ SEM) was 870.6 + 96.5 ppm. Residue levels were unaffected by construction type (slab, crawl, craw...
J P La Fage, K S Delaplane


Wood preservation in Iran
1984 - IRG/WP 3270
The report sketches the history of the use of wood in Iran to the establishment of the country's national forest service and gives some figures for Iran's timber needs by the year 2000. Progress in wood preservation has been slow, although items such as railway sleepers and poles have been pressure treated since the first pressure impregnation plant was erected in 1932. Today the...
P Niloufari, R Cockcroft


Wood attacking insects in urban areas in Sao Paulo State - Brazil
1985 - IRG/WP 1267
From 1974 to 1984 the investigators of Wood Division (IPT) inspected, for insect attack, more than 1,500 buildings of several kinds: commercial, residencial and historical buildings, houses and industries. In all cases, IPT was asked to give advices on control and erradication. During that time three papers concerning this problem were published (Cavalcante, 1976; De Lelis, 1978; Zanotto & Can...
P A Zanotto, M D Canedo, D A T Lelis


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


Relationship between the bending strength and the degree of termite attacks on western hemlock by Coptotermes formosanus Shiraki
1990 - IRG/WP 1434
For the examination of the relationship between the bending strength and the degree of termite attacks, Western Hemlock (Tsuga heterophylla Sarg.) was used. Sixty specimens (4.5 x 4.5 x 82 cm³) were attacked by termites at the culture room of Coptotermes formosanus Shiraki. The termites were introduced on the central parts (10 cm) of specimens. In the case of the 2 points loading, the bending mom...
K Suzuki, T Tanaka


Previous Page | Next Page