IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 1507 documents. Displaying 25 entries per page.


Status of the research and development of a new preservative system (EFPL) for pressure treatment of spruce in Canada
1975 - IRG/WP 348
Our work has been to develop a system which would have the stability of the ACA system and the formulation flexibility of the CCA system enabling properties such as fixation of arsenic, water repellency, appearance and cost to be controlled. Our permeability studies of spruce using a method previously developed indicated that an ammoniacal solution of copper arsenate is an excellent candidate for ...
J Rak, M R Clarke


Manual of a mini treating plant for waterborne preservative treatment of timber and bamboo
1999 - IRG/WP 99-40130
This contributional article includes machinaries and equipments necessary for a small wood treating plant for the pressure treatment of tim bers with waterborne preservatives along with the cost and design. The preservative treatment limitations, treatment schedules and specifications for different products have been described. The cost of a mini treating plant will be 6,00,000 Tk. (13,000 US$), s...
A K Lahiry


Analysis of tebuconazole in wood treated with Tanalith™ E
1999 - IRG/WP 99-20158
A simple gas chromatographic method for determining tebuconazole in Tanalith™ E treated wood is described. A two step sequential extraction procedure with methanol was used. Sample extracts were analysed without cleanup or concentration using capillary column GC with thermionic specific detection. The performance of the method was assessed using radiata pine (Pinus radiata) sapwood, radiata pine...
D E Ferlazzo


Pinus and Eucalyptus fenceposts treated with creosote and solvex tar by hot and cold open-tank process
1987 - IRG/WP 3455
A comparative study of the behaviour of two different wood preservatives, creosote and solvex-tar, was made, using two wood species, Pinus pinaster Ait and Eucalyptus globulus Labill, by the hot and cold open-tank process. Results showed that the creosote behaved better in relation with the uniformity of its distribution in wood. On the other hand, better results were obtained on Pinus for both pr...
M V Baonza Merino


Strength loss associated with steam conditioning and boron treatment of radiata pine framing
1987 - IRG/WP 3438
The combined effect of included defects and wood moisture content on the strength loss of second rotation radiata pine framing following conventional steam conditioning is investigated. The green Modulus of Elasticity (MOE) is reduced by approximately 13% after steaming. When dried after steaming, however, neither the MOE nor MOR is significantly different from unsteamed dried controls....
M J Collins, P Vinden


Soft rot penetration - Effect of groundline maintenance treatment on poles in sevice
1983 - IRG/WP 3263
R S Johnstone


Fire resistance of preservative treated fence posts
1994 - IRG/WP 94-30033
Pine fence posts were pressure treated separately with CCA-C, CCA-wax, CCA-oil and creosote. Treated posts and untreated controls were planted in the ground in a randomised block design, weathered for six months and then subjected to a controlled burning test using two fuel loads. Creosote treatment increased the time that posts were alight whereas CCA treatment had no such effect. However, CCA tr...
P D Evans, P J Beutel, C F Donnelly, R B Cunningham


Soft rot in CCA-treated utility poles in Sweden
1989 - IRG/WP 1398
Soft rot investigations of CCA-treated utility poles (Pinus sylvestris L.) have been conducted throughout large parts of Sweden during 1974-1985. The investigation included 179 utility poles of the State Power Board which had been used for 10-18 years in the different administrative regions from northern to southern Sweden. In addition, 193 telephone poles from the Östersund area and 218 from the...
H Friis-Hansen, H Lundström


Loss of preservatives from treated wood during service
1992 - IRG/WP 92-3734
During the 23rd IRG conference in Harrogate the matter of preservative losses from treated wood during service was raised. We were asked to collect information in this field and ask now for help from you. Many tests have been carried out at a laboratory scale to study fixation and leaching from wood treated with different preservatives. Very little, however, is reported on losses of preservatives ...
M-L Edlund, D Rudolph


Improved techniques designed for evaluation of fungicides in soil for control of dry rot fungus Serpula lacrymans
1985 - IRG/WP 2238
Improved techniques provide a laboratory method for the evaluation of chemicals in soil for control of dry rot fungus Serpula lacrymans. Results with their application to three chemicals were reported. These techniques are useful to eliminate chemicals lacking the necessary toxicity and weatherbility for dry rot control when the chemicals have been applied to the soil....
M Takahashi, K Nishimoto


Thermal treatment of wood: European Processes and their background
2002 - IRG/WP 02-40241
Recent efforts on thermal treatment of wood lead to the development of several processes introduced to the European market during the last few years. The total production capacity of heat treated wood in 2001 is estimated as approx. 165.000 m3. In the paper the different heat processes are presented. The general technology as well as scientific data on the chemical transformation of the cell wall ...
H Militz


Performance of preservative-treated hardwoods with particular reference to soft rot. Report of condition of specimens installed in Victoria, Australia
1980 - IRG/WP 3155
J Beesley, R McCarthy


Fungal and bacterial attack of CCA-treated Pinus radiata timbers from a water-cooling tower
1991 - IRG/WP 1488
Transmission electron microscopy of decaying CCA-treated Pinus radiata timbers from an industrial water cooling tower showed presence of a thick biofilm covering some areas of the wood. The biofilm contained various morphologically distinct forms of microorganisms embedded in a slime. The study provided evidence of the activity of soft rot fungi and tunnelling and erosion bacteria in wood cells. T...
A P Singh, M E Hedley, D R Page, C S Han, K Atisongkroh


The dry rot fungus Serpula lacrymans. Examples of attack and remedial treatment
1988 - IRG/WP 1347
The film deals with several aspects of dry rot attack and eradication in buildings. The detailed biology and morphological charasteristics of the fungus are portrayed. The various forms of mycelial growth, the role of the strands in the nourishment and spread of the fungus, as well as the many types of fruitbody formation are outlined. Environmental and nutritional requirements of the fungus as we...
G Buchwald, B M Hegarty, W Metzner, R Pospischil, H Siegmund, P Grabow


Electrodialytic remediation of creosote and CCA treated timber wastes
2002 - IRG/WP 02-50190
There is a growing concern about the environmental issue of impregnated timber waste management, since an increase in the amount of waste of treated wood is expected over the next decades. Presently, no well-documented treatment technique is yet available for this type of waste. Alternative options concerning the disposal of treated wood are becoming more attractive to study, especially the ones ...
E P Mateus, A B Ribeiro, L Ottosen


Natural durability transfer from sawmill residues of white cypress (Callitris glaucophylla). - Part 3: Full penetration of the refractory sapwood of white cypress
2000 - IRG/WP 00-40167
The heartwood of white cypress, Callitris glaucophylla, is renowned for its termite resistance and durability against decay. The sapwood, which can represent up to 30% of log volume, is non-durable and refractory to conventional preservative treatment. Previous work ascribes the lack of permeability to oily deposits within tracheids and ray cells. Environmental scanning electron microscopy was use...
M J Kennedy, L M Stephens, M A Powell


Types of decay observed in CCA-treated pine posts in horticultural situations in New Zealand
1984 - IRG/WP 1226
The few reported failures of 11-12-year-old horticultural posts in New Zealand in 1982 were caused by brown-rot. A subsequent survey of CCA-treated posts in all the major horticultural areas has revealed decay of many posts. A microscopic examination of these posts has shown decay by brown-rot, white-rot, soft-rot and bacteria. Several types of bacterial decay have been observed....
J A Drysdale, M E Hedley


Improved equipment and technique for high pressure sap displacement impregnation of natural round wood
1972 - IRG/WP 309
Hitherto the main problem in the practical application of high pressure sap displacement impregnation (HPSD) has been in devising a satisfactory cap. Such a cap must be easily fitted to different size log ends to give a leak proof seal. The present contribution describes a new type of cap and sealing system designed to meet these requirements....
C G W Mason, F B Shorland


Possible regulatory status of treated wood waste and implications
1998 - IRG/WP 98-50101-07
In relation to the European Community or the French regulations, treated wood waste can get two different regulatory status: <<recycled product or fuel>> or <<waste>>. Then, into the waste status, two categories are possible for these residues: <<domestic waste and assimilated>> or <<hazardous waste>>. These different status and categories are import...
G Deroubaix


Termite resistance of pine wood treated with chromated copper arsenates
1997 - IRG/WP 97-30128
Two four-week, no-choice laboratory tests were performed with CCA-treated southern yellow pine and radiata pine against Formosan subterranean termites, Coptotermes formosanus. CCA retentions as low as 0.05 kg/m3 (0.03 pcf) provided protection from all but light termite attack (rating of 9 on a 10-point visual scale). Similar and consistent light attack on wafers containing retentions as high as 6....
J K Grace


Application of radio frequency heating to accelerate fixation of CCA in treated round-wood
1999 - IRG/WP 99-40133
The potential of radio frequency heating to accelerate the fixation of chromated copper arsenate (CCA) in treated round-wood was assessed. Pre-dried Douglas-fir and western red cedar round-wood sections were pressure treated with CCA in a pilot plant retort, after which they were placed individually in a pilot radio frequency (RF) chamber. Based upon the color reaction of chromotropic acid with he...
Fang Fang, J N R Ruddick


Laboratory decay test of Burmese in and kanyin treated with three wood preservatives
1982 - IRG/WP 3210
Laboratory decay tests were performed on samples of In (Dipterocarpus tuberculatus Roxb.) and Kanyin (Dipterocarpus alatus Roxb. and Dipterocarpus turbinatus Gaertn f.) pressure treated with three wood preservatives - copper arsenic additive (CAA - a variation of ammoniacal copper arsenate), Arquad C-33 (a waterborne quaternary ammonium formulation), and tributyltin acetate (TBTA) dissolved in eth...
J N R Ruddick, R S Smith, A Byrne


Progress towards controlling soft rot of treated hardwood poles in Australia
1977 - IRG/WP 289
H Greaves


The long-term performance of boron treated joinery in service - A case study
2000 - IRG/WP 00-20208
Joinery treated with borates 23 years ago and in service in residential flats was surveyed and analysed for boron content. The levels of boron still present were sufficient to prevent decay. None of the windows surveyed showed any decay despite the fact that moisture and sapwood contents were conducive to decay....
D J Dickinson, R J Murphy


Effect of water repellents on leaching from CCA treated wood
1995 - IRG/WP 95-50044
CCA treated fence boards brushed with a water repellent finish had consistently lower leaching losses of all CCA components compared to the rate for matched samples without the water repellent. These results are after 12 cycles of simulated rainfall in the laboratory (1800 mm rainfall total) and four months of natural rain exposure in Toronto....
P A Cooper, R MacVicar


Previous Page | Next Page