IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 1366 documents. Displaying 25 entries per page.


Use of the Pilodyn to assess deterioration of treated aspen waferboard after 30 months of outdoor exposure
1986 - IRG/WP 2254
Samples of preservative treated aspen waferboard exposed outdoors for 30 mo. were compared using pin penetrations of the 6 Joule Pilodyn. These results correlated well with rankings of treatment performance based on more laborious standard mechanical tests, and demonstrate the potential for use of the Pilodyn as a tool to evaluate wood composites in test exposures with minimal destruction....
E L Schmidt, M G Dietz


Recycling of impregnated timber: Part 2: Combustion trial
1999 - IRG/WP 99-50132
Totally 270 m3 (61,3 t) of CCA impregnated wood was chipped and incinerated at the combustion plant of Jalasjärvi. After the normal gas cleaning venture scrubbers were tested. After the trial a metal balance was calculated. Ash was treated at the copper smelter of Outokumpu Harjavalta Metals Oy. Condensate waters were transfered to the Outokumpu's CCA production plant and utilized by the...
L Lindroos


Safety clearance of wood preservatives in United Kingdom
1977 - IRG/WP 398
In the United Kingdom the principal route of control of pesticides is through the Pesticides Safety Precautions Scheme (PSPS) which is a non-statutory scheme agreed between government ministries and departments (referred to as "Departments") and associations representing the pesticide industries. The scheme formally began in 1957 covering those pesticides and related substances used in agriculture...
J M Baker


Collaborative tests on the influence of solvent and drying method on the toxic limit of wood preservatives against Basidiomycetes
1974 - IRG/WP 248
Seven institutes from five countries, Austria, England, France, Germany and the Netherlands have collaborated in a study on the influences of solvent and drying method on the toxic limits of wood preservatives against Basidiomycetes tested according to the agar-block method. Two preservatives, a 25% pentachlorophenol-concentrate and tributyltinoxide were applied to pine sapwood and beech and teste...
T Hof


Environmental exposure to wood preservatives
2000 - IRG/WP 00-50165
The OECD Working Group on Pesticides will hold a workshop on Assessing Environmental Exposure to Wood Preservatives within the context of its Biocides Programme (cf. IRG/WP 99-20182). In the area of risk assessment, OECD countries have given highest priority to developing guidance on how exposure assessments for biocides should be performed. Wood preservatives have been selected since most countri...
R-D Peek


Physical and mechanical properties of a suitable constructional timber of Bangladesh
1997 - IRG/WP 97-40102
The study of physical and mechanical properties of lohasirish timber (Derris robusta Roxb.) grown in Bangladesh revealed that the sapwood is whitish to yellowish white, heartwood is dark grey to blackish in colour; the texture is moderately fine, the grain in mostly straight and coarse with whitish rings of parenchyma; shrinkage is moderate; the EMC ranges from 12% to 16%; fuelwood colorific value...
A K Lahiry


Quelques observations biologiques sur la conduite des essais de protection des bois immerges en milieu marin
1976 - IRG/WP 421
P Deschamps


Co-operative field experiment. Performance of preservative-treated hardwoods with particular reference to soft rot: Report of condition of specimens installed in Victoria, Australia
1978 - IRG/WP 3118
J Beesley


Investigation of the fixation in wood of chromated zinc chloride and copperised chromated zinc chloride preservatives
1976 - IRG/WP 372
A biological method of evaluating the extent to which CZC and CCZC preparations are retained in wood in terms of the potential protection which they afford against destruction by Merulius lacrymans (dry rot) is given. CCZC is recommended for protection of wood under moderate leaching conditions, while the use of CZC under such conditions is not recommended....
V N Sozonova, D A Belenkov


A field test with anti-sapstain chemicals on sawn pine timber in Finland
1986 - IRG/WP 3368
Fourteen formulations, each in two concentrations, were tested for effectiveness against sapstain, mould and decay on Scots pine (Pinus sylvestris L.) in a field test in South-Finland. The trial was commenced in June 1985 and finished in October 1985. During the test the boards were infected mainly by mould fungi. In kiln dried boards the protective effects of nine and in green boards of four trea...
L Paajanen


Biological effectiveness of ground-contact wood preservatives as determined by field exposure stake tests
1984 - IRG/WP 3297
Field exposure tests conducted on stakes treated with different creosotes, mixtures of creosote and waxy oil as well as different CCA wood preservatives over a period of 25 years, gave the following results: The CCA preservatives provided excellent biological protection to treated stakes, especially against fungal attack. The CCA Type I, currently approved for use under South African conditions is...
W E Conradie, A Pizzi


Practical testing of wood preservatives to prevent weathering damage and infection by micro-organisms on spruce and pine
1989 - IRG/WP 3530
Brush application, is generally used to prevent wooden window frames from decay caused by influence of weathering and fungi. Accordingly 10 boards of pine (Pinus sylvestris) and spruce (Picea abies) were treated with 10 commercially used wood preservatives. The efficiency of fungicides by using chiptest and blue stain test (EN 152), the effectiveness against weathering as well as the course of col...
R Gründlinger, O Janotta, H Melzer, K Messner


Health and safety aspects of the use of wood preservatives. Preliminary evaluation of the answers to the IRG-Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 56
This preliminary evaluation of the answers to the IRG/WP-Questionnaire only gives a general survey on those questionnaires, which the author received until June 13, 1974. Details, such as correlations between importance of wood preservation and pollution control, could not be considered due to lack of time. For the same reason it was not possible so far, to evaluate the additional remarks given in...
H Willeitner


Final report on world survey of sap displacement impregnation of timber
1975 - IRG/WP 345
The present contribution to the World Survey of Sap Displacement Impregnation of Timber covers the information received since the presentation of the interim report to the 6th Annual Meeting of the International Research Group on Wood Preservation held in Vienna, 20th June 1974....
F B Shorland, C G W Mason


Proposals for a field experiment to determine the performance of preservative treated hardwoods with particular reference to soft rot
1975 - IRG/WP 342
It is proposed to treat a series of hardwood stakes in the UK and install them in different sites around the world. The stakes will include 3 reference species common to every site and 2 locally selected species. The hazard of termites should be avoided in order to limit the study to action of micro-organisms....
D J Dickinson


Preservación de maderas en Bolivia
1986 - IRG/WP 3360
Este documento ofrece datos generales concerníentes a los recursos forestales de Bolivia, las facilidades existentes para preservación de maderas, la investigación y educación en esa materia. Se proporciona información sobre instituciones vinculadas a la actividad y las perspectivas del tratamiento de maderas en el país....
A S Viscarra


New conception for shortering the duration of fungitoxic test of wood preservatives. Part 3: Proposal for interlaboratory test on miniaturisation of wood specimens
1994 - IRG/WP 94-20053
In connection with documents IRG/WP 94-20044 and IRG/WP 94-20052 the proposal for interlaboratory test on miniaturization of wood specimens is given....
J Wazny, J J Krajewski


Fungal degradation of wood treated with metal-based preservatives. Part 2: Redox states of chromium
1996 - IRG/WP 96-10164
Concerns have arisen about the leaching of heavy metals from wood treated with metal-based preservatives, such as chromated copper arsenate (CCA). Of particular concern is the toxic redox state of chromium and arsenic in aging and decayed CCA-treated wood. Generally, hexavalent chromium is more toxic than trivalent chromium and trivalent arsenic is more toxic than pentavalent arsenic. The desired ...
B Illman, S Bajt, T L Highley


The effective control of moulds on freshly impregnated wood
2004 - IRG/WP 04-30352
Beside natural timber it is known, that moulds can also groth at the surface of impregnated wood. This material shows “defects” like resistant dark spots or color changes and causes complaints. During the last years, the problem by moulds seems to increase. Laboratory studies were carried out to show the effect of impregnations against moulds. Wood samples (Pinus sylvestris L.) were impregn...
G Cofta, K Lutomski, P Jüngel


Ground contact performance of wood treated by the MSU process
1990 - IRG/WP 3609
Environmental concerns have prompted a renewed interest in accelerated fixation schemes for CCA-treated wood. Results from stake tests of southern pine (Pinus sp.) treated using a conventional Bethell cycle are compared with matched stakes treated using the MSU Process. The effects of adding boric acid to the preservative formulation are also discussed. Differences among test plots are discussed....
H M Barnes, T L Amburgey, R W Landers


Evaluation and approval of wood preservatives. Unification of European requirements
1988 - IRG/WP 2310
This paper reviews the current activities within the European Homologation Committee for Wood Preservatives (EHC) towards unification of the requirements on evaluation and approval of wood preservatives in Western European countries....
J Jermer


Copper based water-borne preservatives: The use of a thin section technique to compare the protection of wood by copper based preservatives against soft-rot and bacterial decay
1987 - IRG/WP 2286
This paper describes the techniques developed and gives examples of results obtained for the performance of copper based wood preservatives against both the bacterial and fungal hazards....
A M Wyles, D J Dickinson


Effect of leaching temperature and water acidity on the loss of metal elements from CCA treated timber in aquatic conditions. Part 2: Semi-industrial investigation
1995 - IRG/WP 95-50040-13
In continuation of previous leaching research on the quantification and modelling of metal elements released from CCA treated timber, a series of experiments has been carried out dealing with the influence of temperature and pH of the relative aquatic environment. The leaching method used is the Dutch prestandard for building materials, a long term static leaching test simulating practical bank-sh...
G M F Van Eetvelde, W J Homan, H Militz, M Stevens


Co-operative research project on L-joint testing. Progress report to May 1989
1989 - IRG/WP 2338
Further sets of data received from STU (Sweden) after 36 months exposure and Sipad-IRC (Yugoslavia) after 45 months exposure are presented and discussed in conjunction with data reported previously. The new data are generally in agreement with those presented previously and the major difference between institutes continues to be one of rate of colonisation rather than any relative difference in pe...
J K Carey, A F Bravery


Timber Preservation and Sustainable Construction in Australia
2005 - IRG/WP 05-50224-14
Sustainable development has been described as meeting the needs of the present without compromising the ability of future generations to meeting their own needs. (Bruntland 1987) To achieve the sustainable development goal therefore, the maximum performance has to be obtained from existing resources (timber) so that the remaining resource is protected from over-exploitation. Clearly, wood preserva...
J Norton


Previous Page | Next Page