Your search resulted in 193 documents. Displaying 25 entries per page.
Bio-based thermal insulation panels – a way of cascading utilization of post-consumer wood
2024 - IRG/WP 24-50388
Cascading wood utilization is critical to fulfilling a circular economy frame in the wood industry. The work's aim was to apply wood dust from plywood production to the production of innovative bio-based thermal insulation panels. Trametes hirsute fungus was used as a composite binder, and then a composite structure and thermal insulation properties, water absorbability, and strength properties of...
W Perdoch, A Szelag
The non-energy utilization of low-quality wood from the invasive species Prunus serotina
2025 - IRG/WP 25-30814
Alien invasive species in Europe, such as Prunus serotina, can significantly impact ecosystem structure and function. This species provides low-quality timber, which is most often used for energy purposes in the form of biomass. In the era of policies focused on a circular economy, seeking methods to extend the life cycle of raw materials and wood products is necessary. For this purpose, the wood ...
W Perdoch, P Kołwzan
An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka
Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio
Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka
Survey of maintenance management of a residence
2001 - IRG/WP 01-10405
The following points were clarified from the responses to the questionnaire. Termite damage was most common in the bathroom, washroom, and entrance, in that order. Termite damage was most commonly found beneath floors, followed by floor surfaces, and inside walls, in that order. Damage in framing was minimal. Damage in all structural components was most common in the Kyushu region, with the most s...
Y Yamaguchi, M Azuma, Y Hikita, K Nishimoto
Preliminary investigation of biological resistance, water absorption and swelling of thermally compressed pine wood panels
2008 - IRG/WP 08-40396
Wood can be modified by compressive, thermal and chemical treatments. Compression of wood under thermal conditions is resulted in densification of wood. This study evaluated decay and termite resistance of thermally compressed pine wood panels at either 5 or 7 MPa and at either 120 or 150?C for one hour. The process caused increases in density and decreases in thickness of the panels; however, lab...
Ö Ünsal, S N Kartal, Z Candan, R Arango, C A Clausen, F Green III
Minimum standards for habitability in emergency housing
2015 - IRG/WP 15-50312
In this study we evaluated the properties of a prefabricated HOUSING prototype based on a 64mm thick "Structural Insulated Panel" (SIP; hereinafter SIP64), built by two OSB panels bonded with a two component polyurethane adhesive to a high density expanded polystyrene core. This panel was manufactured as a main element for walls in the construction of emergency housing. The thermal insulation of t...
R Garay, F Pfenniger, W Figueroa
Increasing the hardness of wood-composite panels by nanosilver
2016 - IRG/WP 16-40715
Effect of silver nanoparticles on hardness in medium-density fiberboard (MDF) was studied here. A 400 ppm aqueous nanosilver suspension was used at three consumption levels of 100, 150, and 200 mL/kg, based on the dry weight of wood fibers; the results were then compared with the control panels. The size range of silver nanoparticles was 30-80 nm. Composite mats were hot-pressed for 6, 8, and 10 m...
H R Taghiyari, J Norton, K Heidarhaee
Wood preservatives: Field tests out of ground contact. Brief survey of principles and methodology
1976 - IRG/WP 269
This paper contains the following spots:
1.: The general need for field tests. 2.: Interests and limits of field tests in ground contact. 3.: Various methods in use for out-of-ground contact field tests. 4.: Fungal cellar tests are they an alternative to above-ground decay exposure tests? 5.: Conclusions....
M Fougerousse
Thermal treatment of wood: European Processes and their background
2002 - IRG/WP 02-40241
Recent efforts on thermal treatment of wood lead to the development of several processes introduced to the European market during the last few years. The total production capacity of heat treated wood in 2001 is estimated as approx. 165.000 m3. In the paper the different heat processes are presented. The general technology as well as scientific data on the chemical transformation of the cell wall ...
H Militz
Borate thermal treatments
1992 - IRG/WP 92-3715
Green, partially seasoned (air-dried, steam conditioned), or kiln-dried southern pine timbers were treated thermally using 15% disodiumoctaborate tetrahydrate solution. After treatment, sections were stored under non-drying conditions to allow for diffusion. Results showed that effective treatment meeting the AWPA minimum retention (0.17 B203 pcf [2.72 kg/m³] in the outer inch) and penetration (2...
H M Barnes, R W Landers, L H Williams
Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace
The Rubber Ruler: Continuous measurement of dimension changes in wood panels
1994 - IRG/WP 94-20033
A new application for a linear transducer called Rubber Ruler was developed. Rubber Ruler provides a simple and reliable method for continuous monitoring of dimension changes in wood panels. This paper presents the methodology. Results of priliminary experiments designed to simulate the movement in wood panels are also discussed....
Siew K Ho, P Vinden, P Kho
A new ground-contact wide-spectrum organic wood preservative: DNBP
1986 - IRG/WP 3358
A new organic wood preservative, which 25 years field tests have proved to be of efficiency and effectiveness comparable to CCA wood preservatives for ground-contact applications, is presented. Physical and chemical tests, supporting the long term field test results as well as indicating the characteristics of this preservative, are also presented....
W E Conradie, A Pizzi
Natural Resistance of timbers to marine borer attack. COIPM/IRG CO-OPERATION. Final report concerning panels exposed in the sea at Sekondi, Ghana
1979 - IRG/WP 449
The test was carried out according to Document COIPM/72.044, Revised procedure for the testing of naturally durable timbers against marine borers. The panels of the three species remaining in the test at the end of 1978 were removed and assessed visually. An average rating was given to the panels of each species....
F F K Ampong
Corrosion of fasteners in heat-treated wood – progress report after two years’ exposure outdoors
2005 - IRG/WP 05-40296
The corrosion of common fastener materials now in use - mild steel, zinc-coated steel, aluminium and Sanbond Z-coated steel – has been evaluated after two years’ exposure outdoors in untreated and heat-treated spruce (Picea abies) respectively.
Spruce from South-western Sweden was used. The heat-treatment was carried out in Finland according to the ThermoWood process at a maximum temperature ...
J Jermer, B-L Andersson
Improved resistance of Scots pine and Spruce by application of an oil-heat treatment
2000 - IRG/WP 00-40162
Spruce (Picea abies L. Karst.) and Scots pine (Pinus sylvestris L.) were subject to a heat treatment which was carried out in an oil-bath. The aim was to improve the dimensional stability of the treated wood and its resistance against fungi. The bath of vegetable oil provides a uniform heat transfer at temperatures of 180°C, 200°C and 220°C and protects the submersed wood from oxygen. Heat trea...
M Sailer, A O Rapp, H Leithoff
United States Federal Committee on Wood Protection
1971 - IRG/WP 43
A C Jewett
A comparison of the effectiveness of a vacuum oven and a wind tunnel in the accelerated ageing of treated wood by evaporation
1989 - IRG/WP 2334
R J Orsler, G E Holland
4th Report on condition of panels at Sekondi, Ghana
1978 - IRG/WP 445
F F K Ampong
The effects of heat treament on the specific gravity of beech and spruce wood
2003 - IRG/WP 03-40254
The effects of heat treatment on specific gravity of beech (Fagus orientalis) and spruce wood (Picea orientalis) naturally grown and intensively used in forest products industry in Turkey were studied.
The wood samples were cut into 2 x 2 x 3 cm. Heat treatment was than applied to the wood samples at four different temperatures (130 °C, 150 °C, 180 °C and 200 °C) and three different durations...
S Yildiz, Ü C Yildiz, G Colakoglu, E D Gezer, A Temiz
The effect of storage or simulated internal use on the durability of wood based panels to decay fungi
1997 - IRG/WP 97-20106
Wood based panels such as particleboard and medium density fibreboard are experiencing a steady increase in use, in areas from structural to decorative applications. Understanding the "natural" durability of these panel products against basidiomycete fungal decay is therefore of great importance. Various methods have been proposed or are under development to test the durability/susceptibility of v...
S F Curling, R J Murphy, J K Carey
Durability of different heat treated materials from industrial processes in ground contact
2005 - IRG/WP 05-40312
In this study the durability of heat treated wood originating from four different European industrial heat treatment processes in ground contact was examined. The manufacturers of heat treated material were: PLATO Hout B.V./Netherlands, Thermo Wood/Finland, New Option Wood/France and Menz Holz/Germany where Oil-Heat treated Wood (OHT) is produced.
All heat treated materials showed significantly i...
C R Welzbacher, A O Rapp
The effects of heat treatment on the toughness of beech wood
2004 - IRG/WP 04-40283
The effects of heat treatment on toughness of beech (Fagus orientalis) wood naturally grown and intensively used in forest products industry in Turkey were studied.
The wood samples were cut into 5 x 5 x 5 cm. Heat treatment was than applied to the wood samples at three different temperatures (130 °C, 150 °C and 180 °C) and three different durations (2 h, 6 h and 10 h) under air atmospheres.
...
S Yildiz, Ü C Yildiz, E D Gezer, Ali Temiz, E Dizman