IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 942 documents. Displaying 25 entries per page.


Laboratory termite testing of copper boron tebuconazole
2000 - IRG/WP 00-20192
The American Wood Preservers' Association laboratory choice and no choice termite test (AWPA E1-97) was performed on a formulation of copper azole, which is comprised of copper, boric acid, and tebuconazole. The formulation tested has a ratio of copper:boric acid:tebuconazole of 25:25:1. So as to examine the impact of leaching, the southern yellow pine wafers were treated with and without...
R F Fox, E A Pasek, J Patel


Laboratory evaluation of six commercial termiticides against subterranean termite, Coptotermes gestroi Wasmann
1994 - IRG/WP 94-30034
Small specimens of Heavea brasiliensis (10 x 10 x 20 mm³) were exposed to the laboratory colony of Coptotermes gestroi Wasmann for 4 months after dip- or brush-treatment with six commercially available emulsifiable termiticides (alpha-cypermethrin, cypermethrin, permethrin, bifenthrin, chlorpyrifos and chlordane). Synthetic pyrethroids and chlorpyrifos were effective as well as 1% treatment of ch...
Y Sornnuwat, C Vongkaluang, T Yoshimura, K Tsunoda, M Takahashi


Screening of the efficacy of tall oils against wood decaying fungi
2004 - IRG/WP 04-30354
Tall oil is a by-product in pulping of resinous wood by the sulphate process. Tall oil contains a complex mixture of wood extractives. Some of these extractives act as natural protection against wood decaying fungi while other serve as nutrition for the fungi. This report describes a screening of the efficacy of four refined tall oils with different chemical composition on wood decaying fungi. ...
G Alfredsen, P O Flæte, A Temiz, M Eikenes, H Militz


Kerfing reduces checking in ACA-treated western white spruce poles
1988 - IRG/WP 3477
Western white spruce poles, pressure treated with pentachlorophenol and ammoniacal copper arsenate (ACA) were installed in the Westham Island test site. The pentachlorophenol treated poles were unkerfed, while both unkerfed and kerfed ACA poles were placed in test. The checking and kerf width and depth were recorded at the time of installation. After ten years of weathering the checking characteri...
J N R Ruddick


Comparison of performance of wood preservatives in laboratory and field tests of treated commodities
1993 - IRG/WP 93-20010
The purpose of laboratory tests for evaluating efficacy of wood preservatives is usually to establish toxic values against standard strains of wood decay fungi. Exposure conditions are usually chosen as optimal for fungal growth. Toxic values so determined serve as a guide as to expected performance of the preservative in field stake tests or in above ground exposure tests. Test material is select...
M E Hedley


Non-destructive detection of the presence and behaviour patterns of wood-destroying insects
1988 - IRG/WP 2302
An apparatus, designed for the automatic recognition of the presence and of specific behaviour patterns of wood-boring insects, is introduced. From a wood sample, a mixture of noise and action induced substratum vibrations is picked up, amplified, filtered and translated into a sequence of computer-readable numbers which are passed to a microcomputer-based signal-pattern-recognition. If an incomin...
M Pallaske


The effectiveness of three tributyltin compounds in beech against soft rot fungi using a soil-bed technique: A preliminary report
1986 - IRG/WP 3390
The effectiveness, towards soft rot fungi, of bis (tributyltin) oxide, tributyltin ethanesulphonate (TBTES) and benzyltributylammonium tributyldichlorostannate in both leached and unleached beech stakes is compared to that of a CCA preservative (Tanalith CT 106), using a soilbed technique. In addition, the effect of test solvent (water or toluene) on the performance of TBTES is evaluated. Total ti...
R Hill, A H Chapman, B Patel, A Samuel, J K Carey


Computer-assisted ranking of potential biocontrol fungi based on data from laboratory screening trials
1993 - IRG/WP 93-10023
Forty two fungal isolates were screened for antibiotic activity. In these sceering tests inhibition of target wood decay fungi was expressed as a series of numerical scores for each isolate. These scores, along with values for 5 other charactetistics, were used to assess the isolates. Using selection indices, isolates were judged on the basis of all the characteristics combined and, ranked in orde...
M W Schoeman, D J Dickinson


Field evaluation of the above-ground susceptibility of Pinus heartwood and untreated or treated sapwood to two species of Australian subterranean termites
1996 - IRG/WP 96-10147
Plantation-grown Pinus elliottii, Pinus caribaea and Pinus radiata specimens containing heartwood and untreated or preservative-treated sapwood were exposed above ground to the subterranean termites Coptotermes acinaciformis or Mastotermes darwiniensis near Sydney (NSW), Brisbane and Townsville (Qld), and Darwin (NT), using a variety of exposure techniques. Heartwood of Pinus elliottii and Pinus c...
M J Kennedy, J W Creffield, R H Eldridge, B C Peters


Isolation and identification of the trail pheromone of the subterranean termite Reticulitermes speratus (Kolbe) (Isoptera: Rhinotermitidae)
1990 - IRG/WP 1459
The trail pheromone was successfully isolated from whole body extract of the termite Reticulitermes speratus (Kolbe) through various chromatographic reactions. Its trail-following activity was examined by bioassays. The primary structure of the pheromone was determined as normal chain dodecatrien-1-ol by capillary GC-MS analysis. Moreover, by means of capillary GC-MS and capillary GC-FTIR analyses...
M Tokoro, M Takahashi, R Yamaoka


Facility for Conducting Field Tests on Coptotermes formosanus at LSU Agricultural Center
2003 - IRG/WP 03-20274
Efforts by Louisiana State University Agricultural Center (LSU AgCenter) and Mississippi State University (MSU) research scientists, to conduct cooperative research on C. formosanus and other wood-related topics, have led to establishing an FST field test site at the LSU Agricultural Center Citrus Research Experiment Station, Port Sulfur, Louisiana. A minimum of 32 termite colonies will be establi...
W R Smith, T L Amburgey, G Henderson, D R Ring


Alternatives to preliminary oven-drying prior to spot-testing treated timber for borate or TBTN preservative penetration
1995 - IRG/WP 95-20067
Commonly-used penetration test procedures for timber treated with borate or organotin wood preservatives demand preliminary oven-drying before application of the spot-testing reagent(s), in order to achieve reliable results. The delay of 12 hours or more during oven drying is often a nuisance. Modifications to the spot-testing procedures, involving alternative solvents and acidification conditions...
M J Kennedy, A Zosars, J Norton


Laboratory evaluation of the termiticidal effectiveness of TanalithÒ 3485
1995 - IRG/WP 95-10109
The termiticidal effectiveness of the copper azole TANALITH 3485 was evaluated with the benchmark preservative TANALITH C in a laboratory bioassay using two species of subterranean termites, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Retentions of TANALITH 3485 tested were 0.15, 0.24, 0.285 and 0.40% m/m Cu and for TANALITH C 0.025, 0.05, 0.08 and 0.095% m/m Cu. Un...
J W Creffield, J A Drysdale, N Chew, N-K Nguyen


A soil-less test of treated wood
1978 - IRG/WP 2105
The objective of this work is to devise an accelerated test for preservatives to be used in places away from soil contact. There may be compounds or mixtures which will protect wood or wood derived materials from decay in such articles as sash and doors, boardwalks, steps, laminated arches and the like, and possess properties that make them preferable to the heavy-duty preservatives used for poles...
E A Behr


Lab and field test results for wood treated with polymeric alkylphenol polysulfide
2001 - IRG/WP 01-30268
A new wood preservative based on polymeric alkyphenol polysulfide (PXTS-A) is being evaluated in a series of laboratory and field tests and the results continue to show promise. A modified formulation (PXTS-B), which contains additives to reduce the viscosity, is being evaluated along with the original formulation. Soil block decay tests comparing PXTS-B with CCA-C indicate that PXTS-B is equally ...
J Goswami, A Abramson, R Buff, D D Nicholas, T Schultz


Properties-enhanced albizzia particleboards by incorporating fungicide and insecticide in the glue
1994 - IRG/WP 94-30060
Preservative-treated particleboards were prepared by using tropical fast-growing albizzia and adding fungicides and insecticides to the adhesive-glue. the physical and biological properties of these boards were evaluated. No significant reduction in bending or internal-bond strength due to incorporation of the chemicals was detected. Treated particleboards effectively resisted attack by Coptoterme...
B Subiyanto, S Yusuf, Y Imamura, S Fushiki, T Saito, T Katuzawa


Performance of Two Imidacloprid-Treated Malaysian Hardwoods in an Accelerated Aboveground Termite Test
2005 - IRG/WP 05-30389
The performance of the chloronicotinyl insecticide imidacloprid as a wood protecting termiticide, under a simulated Malaysian biological hazard class H2 (exposure aboveground indoors against termites and wood borers), was evaluated by a novel termite field test protocol. Replicate end-grain sealed air dried test blocks (20 x 20 x 20 mm) of two Malaysian hardwoods, Kembang Semangkok (Scaphium spp.)...
A H H Wong


An investigation of the factors influencing the rate of deterioration of timber samples due to microfungi in laboratory tests
1997 - IRG/WP 97-20116
An investigation was performed into the comparative performances of test 1 (vermiculite burial) and test 2 (soil burial) as described in ENV 807. Two test preservatives were used - copper naphthenate and propiconazole. Copper chromate was included as a reference preservative. The wood species used was beech (Fagus sylvatica). Test 1 was performed using both a mixed inoculation of the five stipulat...
I J Herring, D J Dickinson, S M Gray, J K Carey


Soil treatment tests with the three products of boric acid for the prevention of the hyphal growth of Serpula lacrymans
1992 - IRG/WP 92-3693
Laboratory soil treatment tests were conducted for the evaluation of fungicidal or fungistatic effect of boric acid products against Serpula lacrymans. Boric acid products tested were the following three: a thickened boric acid solution in triethanolamine, boric acid-silica gel complex granules, and a nonwoven fabric laminated with a polypropylene film and coated with boric acid granules on one si...
S Doi, A Yamada, Y Mineki, M Mori


Comparison of the FRIM and forest research laboratory methods for screening of anti-sapstain formulations
1999 - IRG/WP 99-20170
Two laboratory methods for screening of anti-sapstain formulations were compared. The method adopted by the Forest Research Institute Malaysia (FRIM) involved 3 weeks assessment of rubberwood (Hevea brasiliensis) blocks, dipped in the candidate formulation and inoculated with mycelial/spore suspension of sapstain (Botryodiplodia theobromae) or decay (Schizophyllum commune) fungi, and incubated on ...
A H H Wong, D R Eden, C M Chittenden, M E Hedley, R N Wakeling


Relative merits of laboratory and field tests for assessing wood decay resistance
1993 - IRG/WP 93-20009
Laboratory and field trials have long been employed for assessing natural durability of a variety of wood species, but there is a continuing debate concerning the relative merits of approach. While laboratory tests provide carefully controlled conditions for decay, they are often criticized for being too artificial to produce meaningful results. Conversely, field trials often vary widely between t...
T C Scheffer, J J Morrell


Control of termite attack using a trapping method and acoustic emission (AE) monitoring a case study at an electric power plant
1997 - IRG/WP 97-10224
To prevent subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) from invading the buildings of an electric power plant and to control their attack, artificial traps were buried around the buildings. The attack of the termites in and around the traps was monitored by detecting acoustic emissions (AE) generated by the feeding behavior of the workers. The cylindric...
Y Fujii, Y Imamura, E Iwatsubo, S Yamamoto


Field tests with Antiblue and Biocide TT for the prevention of sapstain and mould fungi on Pinus elliottii timber
1992 - IRG/WP 92-3682
Freshly cut and sawn Pinus elliottii timber was dipped in four concentrations of Antiblue (active ingredient sodium pentachlorophenate) and Biucide TT (local substitute), at four immersion times and stacked in the open at Chisengu sawmill. Five weeks later, the timber was assessed for the incidence and intensity of stain and mould. The results showed that Antiblue was the better chemical providing...
A J Masuka


Some studies on fungal deterioration of rubber wood (Hevea brasiliensis)
1980 - IRG/WP 2140
For the sreening of anti-stain chemicals trials with selected agricultural fungicides and new chemicals were carried out. Botryodiplodia theobromae, Aspergillus sp. and Penicillium sp. were used at test organisms. For testing the durability of rubber wood (Hevea brasiliensis) suitable local rotting fungi (Basidiomycetes), based on high degrading power, which may later be employed in standard tests...
A Sujan, A G Tan, M Stevens


Antifeedant activities of flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki
1999 - IRG/WP 99-10305
Antifeedant activities of some flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki were examined with no-choice and two-choice tests. The activities of these compounds were considered in relation to their chemical structures. All flavonoids tested showed antifeedant activities whereas catechinic acid without A-ring and pyran ring in the molecule ...
W Ohmura, S Doi, M Aoyama, S Ohara


Previous Page | Next Page