IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 486 documents. Displaying 25 entries per page.


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


Feasibility of termite control using crushed cement-stabilized sludge (Polynite) as a physical barrier and acoustic emission (AE) monitoring
2000 - IRG/WP 00-10381
In Japan, the damages by the subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) are more common. Recently, the more attention is paid to the methods of the termite controls of less- or non-chemical. As one of the non- chemical treatment, physical barrier using particles as basalts 1) , granites, and gravels 2) were investigated in terms of its safety, cost eff...
Y Yanase, M Shibata, Y Fujii, S Okumura, K Iwamoto, T Nogiwa, T Yoshimura, Y Imamura


Termite physical barriers: Update on retrofitting Granitgard around 'mock-up' buildings after three years
1995 - IRG/WP 95-10118
This field experiment was installed three years ago (March 1992) to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite aggregate or "screenings", as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and ...
B M Ahmed, J R J French


Termite physical barriers: Is retrofitting with Granitgard an option?
1993 - IRG/WP 93-40011
Granite particles within the range of 2.4 to 1.7 mm diameter were recently adopted by the Standards Association of Australia as an alternative treatment to soil chemical barriers in protecting new buildings against subterranean termites. The granite substrate is sold under the commercial name, "Granitgard". However, there are many existing buildings that have no chemical or physical subterranean t...
J R J French, B M Ahmed


Termite physical barriers: Update on retrofitting Granitgard around 'mock up' buildings after four years
1996 - IRG/WP 96-10140
This field experiment was installed four years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name, Granitgard, as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are ...
B M Ahmed, J R J French


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
This field experiment was installed five years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name Granitgard™, as a physical barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight ...
J R J French, B M Ahmed


Performance of sintered glass screening as a potential physical barrier against subterranean termites in the laboratory and after 4 years of field test
2008 - IRG/WP 08-10646
This paper describes the performance of sintered glass screenings as a potential physical barrier against the subterranean termites, Coptotermes acinaciformis and Mastotermes darwiniensis in the laboratory and after four years of field testing in active above-ground mound colonies of Coptotermes lacteus. The laboratory results suggest that sintered glass is a viable control option against Copto...
J R J French, B M Ahmed (Shiday)


Whole-of-house protection from subterranean termite attack and damage after four years of field exposure
2008 - IRG/WP 08-10665
This study reports the condition of the whole-of-house termite protection test in tropical Australia after four years. The study was designed to provide maximum protection to whole-of-house timbers in a natural situation posing the highest hazard from subterranean termite populations. The houses were constructed either on concrete slabs or suspended floors using untreated and treated timber fram...
B M Ahmed (Shiday), J R J French, S R Przewloka, P Vinden, J Hann, C Y Adam


Preliminary laboratory and field evaluation on the performance of Rubbermite as a graded physical barrier against subterranean termite species in Australia
2012 - IRG/WP 12-10766
This paper describes the performance of Rubbermite as a potential graded particle barrier against two subterranean termite species of Coptotermes in laboratory and field test. The results of these bioassays suggest that Rubbermite is a viable control option against Coptotermes species in Australia, particularly against Coptotermes acinaciformis (Froggatt) and Coptotermes lacteus (Froggatt). Rubber...
B M Ahmed (Shiday), J R J French


Termite Management and the U.S. Experience: A Case for Wood Treatment & Integrated Control
2015 - IRG/WP 15-30678
A brief overview of termite control is given using specific experiences from the U.S.A. Five major types of termite treatment now prevail: soil applied chemical barriers, in-structure chemical barriers (in-situ applied wood and foundation treatments), physical barriers, treated wood and termite baits. In general, ‘stand-alone’ pretreatments or ‘primary’ treatments are often discussed and ...
J D Lloyd, K van den Meiracker


Evaluation of Particulate Materials as a Physical Barrier against Termites under Floor of Experiment House
2017 - IRG/WP 17-10900
In Japan, the damages by the subterranean termites (Coptotermes formosanus and Reticulitermes speratus) are more common. Recently the more attention is paid to the less- or non-chemical methods for termite control. As a non-chemical treatment, physical barriers using particles such as gravels were investigated in terms of environmental safety, cost effectiveness, and duration of performance, and t...
Y Yanase, Y Fujiwara, Y Fujii, T Mori, T Yoshimura, S Doi


Granitgard used as a partial and perimeter barrier in the protection of buildings against subterranean termites
1995 - IRG/WP 95-10114
The graded granite subterranean termite physical barrier, commercially marketed as Granitgard, has a Certificate of National Accreditation issued by the Australian Building Codes Board, and is included in Australian Standards. After several years in developing the specifications and installation techniques for Granitgard, it may be used to protect almost all footing designs. Granitgard can be simp...
D M Ewart, J R J French


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Physical and biological properties of albizzia waferboards modified with cross-linking agents
1995 - IRG/WP 95-40043
Chemically-modified low-density waferboards with cross-linking agents were produced using a fast-growing species of hardwood albizzia (Paraserienthes falcata Becker) as a raw materials and isocyanate resin as a glue adhesive. For the chemical modification, the vapor-phase formalization of the boards and the pad-dry-cure treatment of wafers with cross-linking agents were employed. The vapor-phase f...
S Yusuf, Y Imamura, M Takahashi, K Minato


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


Techniques for field assessment of particulate termite barriers
2000 - IRG/WP 00-10376
Field testing of particulate termite barriers poses problems different from those encountered when testing preservatives or soil termiticides. To ensure an adequate level of challenge, and minimise the risk of a Type II error, the experimental design must promote termite activity and provide a significant, readily detectable, food source which can only be reached by penetrating the test barrier. I...
D M Ewart, E R Rawlinson


Studies on the infesting behaviour of the Formosan termite, Coptotermes formosanus Shiraki and its physical control
1983 - IRG/WP 1174
An outline of termite damage to buildings in Japanese National Railways, wood-infesting behavior, attacked traces in PVC-sheathed cables by termites, detection method of termites and the physical control method of the Formosan termite are given in the present paper....
K Yamano


Termite barriers for new construction
2000 - IRG/WP 00-10341
Subterranean termite protection in Australia has traditionally relied upon the creation of a zone of poisoned soil under and around the structure to prevent termite attack from the ground. The transition away from persistent soil poisons which began with the withdrawal of cyclodienes in 1995 provided market opportunities for innovative barrier systems. The new barrier systems currently being used ...
D M Ewart


Longterm monitoring of termite activity on multiple feeding sites: a laboratory method intended for the determination of attractant/repellent properties of wood preservatives and baits
2001 - IRG/WP 01-20225
A method is introduced allowing the continuous monitoring of the activity of a small laboratory termite- colony at 8 different feeding sites simultaneously. The test assembly consists of a small central polycarbonate-tube containing a colonie of Reticulitermes santonensis (de Feytaud) beeing connected with 8 external feeding sites by small glass-capillaries. The termites passing through the glass ...
M Pallaske, E Graf, H Takiuchi


Protection of buildings, other structures and materials in ground contact from attack by subterranean termites with a physical barrier - a fine mesh of high grade stainless stee
1993 - IRG/WP 93-10014
A new type of physical barrier for the prevention of attack by subterranean termites on buildings, other structures and materials in ground contact - a fine mesh of highalloy (originally 304, now 316) stainless steel - has recently been developed and patented worldwide by industry in Australia. The termite resistance of the material was assessed by CSIRO in laboratory and field trials. In the labo...
M Lenz, S Runko


Principles behind the laboratory assessment of materials with subterranean termites - Recent perspectives and shifts in emphasis
1986 - IRG/WP 1291
Laboratory assessments of materials against termites aim to give an indication of the likely performance of materials in the field. To meet this objective, test procedures have to provide the conditions that promote the most vigorous activity of the insects. Implications of recent findings on inter- and intracolony variability in vigour, the need to monitor termite activity with differing types of...
M Lenz


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


Next Page