Natural durability transfer from sawmill residues of white cypress (Callitris glaucophylla). - Part 4: Analysis of extracts and treated wood for active components
2000 - IRG/WP 00-20215
In order to facilitate the commercial implementation of a large project aimed at recovering 'waste' durability components from sawmill residues of Callitris glaucophylla, it has been essential to develop analytical methodology for the important bioactive components of the heartwood extract. This methodology will be used 1) to standardise the activity of successive production batc...
Hui Jiang, M J Kennedy, L M Stephens


Relative tolerance of CCA by larvae and adults of the common shipworm, Bankia gouldi
1992 - IRG/WP 92-4174
Southern pine sapwood "2 x 4´s" were created by bolting together four panels 13 mm thick by 89 mm wide by 457 mm long. The two outer laminates were untreated and the two inner laminates were each treated to different CCA retentions, ranging from 8.0 to 43.2 kg/m³. Test specimens were exposed from May to October in a tributary of the Chesapeake Bay. Larvae were unable to settle on and burrow into...
B R Johnson


Laboratory evaluation of copper naphthenate pressure treatments against the Formosan subterranean termite
1993 - IRG/WP 93-10005
Southern pine wafers and Douglas-fir cubes pressure treated with copper naphthenate in AWPA P9 Type A oil or in toluene were evaluated for resistance to attack by the Formosan subterranean termite, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae). Wood samples were pressure treated to target copper retentions of 0.040, 0.075, 0.095, or 0.150 pcf, conditioned to simulate field exposure, a...
J K Grace, R T Yamamoto, P E Laks


Effect of climate, species, preservative concentration and water repellent on leaching from CCA-treated lumber exposed above ground
2001 - IRG/WP 01-50178
Few studies have examined leaching of chromated copper arsenate (CCA) from treated wood in above ground exposures due to the assumption that leaching is less severe compared to wood in continuous contact with soil or water. However, a significant portion of CCA treated wood is used for above ground applications, exposing considerable volumes of the preservative to precipitation and potential leach...
J L Taylor, P A Cooper


Prevention of Termite Tubing Over Non-Wood Construction Materials Using Glycol Borate
2004 - IRG/WP 04-30358
Glycol borates have been demonstrated to prevent termite tubing and attack of wood materials and are extensively used as termite preventative applications in new construction in the USA. This study evaluated the ability of such systems to prevent Formosan subterranean termite tubing over non-wood materials. Concrete was selected as a common inert construction material and tests were carried out ...
W R Smith, J D Lloyd


Field testing of nootkatone and tetrahydronootkatone wood treatments against Coptotermes formosanus Shiraki
2003 - IRG/WP 03-30308
A component of Alaskan yellow cedar, citrus oil, and vetiver oil, nootkatone, and its derivative, tetrahydronootkatone, were tested for their potential as wood treatments against Coptotermes formosanus. Wood treatments dipped in 1% and 5% nootkatone and tetrahydronootkatone in ethanol or vacuum impregnated (5% only) were tested in a natural setting using termite infested bald cypress trees along t...
K E Nix, G Henderson, R Laine


Test methods for wood preservatives against Lyctus: (1) Testing of treated veneer. (2) Testing of glue-line treated plywood. (Laboratory methods)
1977 - IRG/WP 293
Powder-post beetles destroy large quantities of veneer and plywood. Two test procedures are described which can be used to support application-oriented research into veneer and plywood preservatives. These procedures simulate practical conditions on a laboratory scale. Their characteristic feature is that wood species of special susceptibility are used for the tests; the susceptibility of the spec...
S Cymorek


Ability of an acoustic inspection device to detect internal voids in untreated pole sections
2002 - IRG/WP 02-20246
Detecting deterioration before substantial losses in material properties occur poses a major challenge to most wood users. While physical inspection techniques such as drilling or coring are useful, these methods can miss small pockets of damage and they lack the ability to detect early or incipient decay. The development of sonic test methodologies has created the potential for detecting change...
J J Morrell, R G Rhatigan


Water-borne DNBP wood preservatives - Preparation and performance
1987 - IRG/WP 3407
Three waterborne wide-spectrum ground-contact DNBP (2-sec-butyl-4,6-dinitrophenol) wood preservative formulations and their performance are presented. Two are double-treatment formulations in which insolubilization and precipitation of the preservative is attained by salt formation or by formation of a water insoluble Cu/NH3/DNBP complex of formula [DNBP]2 [Cu(NH3)2]2 the clarified structure of wh...
W E Conradie, A Pizzi


Incidence of soft rot in creosoted poles
1992 - IRG/WP 92-1554
A further population of creosote-treated poles has been assessed for the occurrence of soft rot, as a continuation of work reported in IRG Document No. IRG/WP/1368. The outer 1 cm of each core was assessed microscopically and graded for the presence of soft rot cavities in the wood cell walls; with further assessments taken at a consecutive 1cm interval for cores showing positive findings. Followi...
D J Dickinson, P W McCormack, B Calver


Aboveground Microbial Decay Test of Biocide Treated and Untreated Wood Exposed to Danish and Humid Tropical Climates
2004 - IRG/WP 04-20306
A co-operative study was initiated to compare the aboveground field decay test of untreated and preservative-treated timbers under Nordic (Danish) and a representative humid tropical (Malaysian) environment according to CEN standard method. Matched specimens of untreated and both preservative-impregnated and surface-treated wood were simultaneously exposed at The Danish Technological Institute (DT...
A H H Wong, N Morsing, K H Henriksen, S Ujang


Laboratory termite testing of copper boron tebuconazole
2000 - IRG/WP 00-20192
The American Wood Preservers' Association laboratory choice and no choice termite test (AWPA E1-97) was performed on a formulation of copper azole, which is comprised of copper, boric acid, and tebuconazole. The formulation tested has a ratio of copper:boric acid:tebuconazole of 25:25:1. So as to examine the impact of leaching, the southern yellow pine wafers were treated with and without...
R F Fox, E A Pasek, J Patel


Laboratory evaluation of six commercial termiticides against subterranean termite, Coptotermes gestroi Wasmann
1994 - IRG/WP 94-30034
Small specimens of Heavea brasiliensis (10 x 10 x 20 mm³) were exposed to the laboratory colony of Coptotermes gestroi Wasmann for 4 months after dip- or brush-treatment with six commercially available emulsifiable termiticides (alpha-cypermethrin, cypermethrin, permethrin, bifenthrin, chlorpyrifos and chlordane). Synthetic pyrethroids and chlorpyrifos were effective as well as 1% treatment of ch...
Y Sornnuwat, C Vongkaluang, T Yoshimura, K Tsunoda, M Takahashi


IRG/COIPM INTERNATIONAL MARINE TEST - to determine the effect of timber substrate on the effectiveness of water-borne salt preservatives in sea-water. Progress Report 3: Report of first inspection of samples at Lae, Papua New Guinea
1978 - IRG/WP 446
Samples for the international marine test were placed on frames numbered I to VII. Frames numbered VII of both CCA and CCB trials are being stored dry in the laboratory at F.P.R. & D.C. Frames I to VI of both trials were suspended in the sea at Lae Harbour (Morobe Province, Papua New Guinea) on 6th December 1977. The first inspection of the CCA trial was carried out on 8th June 1978, at which ...
S M Cragg, C R Levy


Interim balance after 20 months of lap-joint exposure
1999 - IRG/WP 99-20164
The application of natural resins and integrated resin systems to improve the performance of Pinus sylvestris was assessed in a lap-joint test according to DIN V ENV 12037 (1996). Lap-joints of Pinus sapwood were exposed at the test field in Hamburg (Germany) in May 1997. The treated lap-joints were assessed with regard to the performance of the resin treatments out of ground. The exposure of lap-...
M Sailer, A O Rapp, R-D Peek, A J Nurmi, E P J Beckers


Resistance to decay of particle boards: Presentation of a test method
1986 - IRG/WP 2260
The experimentations were undertaken on particle boards 35 and 50 mm thick. The rot resistance tests were carried out on specimens whose dimensions were 600 x 75 x 35 mm³ for particle boards 35 mm thick and 800 x 75 x 50 mm³ for particle boards 50 mm thick according to a method derived from the one described in the documents IRG/WP/2214 and IRG/WP/2243. Two exposure periods were used: 12 and 16 ...
G R Y Déon, N Trong


Evaluation of outdoor weathering performance of modified wood
2004 - IRG/WP 04-20296
Interlace treated, oil treated, silicon treated as well as untreated Scots pine samples have been exposed outdoors. For evaluating the samples on their long term performance an internal standard had been developed. Parameters to be determined were the uptake of liquid water (submersion test), weight variation during exposure, crack performance, surface roughness and colour change. This paper disc...
Y Schulte, S Donath, A Krause, H Militz


Field evaluation of the above-ground susceptibility of Pinus heartwood and untreated or treated sapwood to two species of Australian subterranean termites
1996 - IRG/WP 96-10147
Plantation-grown Pinus elliottii, Pinus caribaea and Pinus radiata specimens containing heartwood and untreated or preservative-treated sapwood were exposed above ground to the subterranean termites Coptotermes acinaciformis or Mastotermes darwiniensis near Sydney (NSW), Brisbane and Townsville (Qld), and Darwin (NT), using a variety of exposure techniques. Heartwood of Pinus elliottii and Pinus c...
M J Kennedy, J W Creffield, R H Eldridge, B C Peters


Isolation and identification of the trail pheromone of the subterranean termite Reticulitermes speratus (Kolbe) (Isoptera: Rhinotermitidae)
1990 - IRG/WP 1459
The trail pheromone was successfully isolated from whole body extract of the termite Reticulitermes speratus (Kolbe) through various chromatographic reactions. Its trail-following activity was examined by bioassays. The primary structure of the pheromone was determined as normal chain dodecatrien-1-ol by capillary GC-MS analysis. Moreover, by means of capillary GC-MS and capillary GC-FTIR analyses...
M Tokoro, M Takahashi, R Yamaoka


Facility for Conducting Field Tests on Coptotermes formosanus at LSU Agricultural Center
2003 - IRG/WP 03-20274
Efforts by Louisiana State University Agricultural Center (LSU AgCenter) and Mississippi State University (MSU) research scientists, to conduct cooperative research on C. formosanus and other wood-related topics, have led to establishing an FST field test site at the LSU Agricultural Center Citrus Research Experiment Station, Port Sulfur, Louisiana. A minimum of 32 termite colonies will be establi...
W R Smith, T L Amburgey, G Henderson, D R Ring


Biological control of decay
1975 - IRG/WP 135
One approach to the biological control of decay in standing poles, live trees or seedlings is with microbial immunising commensals or IC.·These are microorganisms able to grow in the wood without damaging it and as a result of such growth to protect against certain types of decay. Scytalidium and Trichoderma spp have been tested in the field. The latter species have shown an establishment rate in...
J Ricard


Laboratory evaluation of the termiticidal effectiveness of TanalithÒ 3485
1995 - IRG/WP 95-10109
The termiticidal effectiveness of the copper azole TANALITH 3485 was evaluated with the benchmark preservative TANALITH C in a laboratory bioassay using two species of subterranean termites, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Retentions of TANALITH 3485 tested were 0.15, 0.24, 0.285 and 0.40% m/m Cu and for TANALITH C 0.025, 0.05, 0.08 and 0.095% m/m Cu. Un...
J W Creffield, J A Drysdale, N Chew, N-K Nguyen


Lab and field test results for wood treated with polymeric alkylphenol polysulfide
2001 - IRG/WP 01-30268
A new wood preservative based on polymeric alkyphenol polysulfide (PXTS-A) is being evaluated in a series of laboratory and field tests and the results continue to show promise. A modified formulation (PXTS-B), which contains additives to reduce the viscosity, is being evaluated along with the original formulation. Soil block decay tests comparing PXTS-B with CCA-C indicate that PXTS-B is equally ...
J Goswami, A Abramson, R Buff, D D Nicholas, T Schultz


Properties-enhanced albizzia particleboards by incorporating fungicide and insecticide in the glue
1994 - IRG/WP 94-30060
Preservative-treated particleboards were prepared by using tropical fast-growing albizzia and adding fungicides and insecticides to the adhesive-glue. the physical and biological properties of these boards were evaluated. No significant reduction in bending or internal-bond strength due to incorporation of the chemicals was detected. Treated particleboards effectively resisted attack by Coptoterme...
B Subiyanto, S Yusuf, Y Imamura, S Fushiki, T Saito, T Katuzawa


Status of Work on OECD Test Guidelines for Emissions of Wood Preservatives to the Environment
2005 - IRG/WP 05-50224-3
In April, 2003, OECD published an ESD on wood preservatives that provides guidance on how to estimate emissions: 1) during the wood preservative application processes and storage of treated wood prior to shipment; and 2) from treated wood-in-service. The ad hoc Expert Group that developed the wood preservatives ESD identified the need to develop Test Guidelines to estimate the amount of biocides ...
W Jakob