Your search resulted in 683 documents. Displaying 25 entries per page.
The effective control of moulds on freshly impregnated wood
2004 - IRG/WP 04-30352
Beside natural timber it is known, that moulds can also groth at the surface of impregnated wood. This material shows “defects” like resistant dark spots or color changes and causes complaints. During the last years, the problem by moulds seems to increase.
Laboratory studies were carried out to show the effect of impregnations against moulds. Wood samples (Pinus sylvestris L.) were impregn...
G Cofta, K Lutomski, P Jüngel
First draft of a monographic card for Gloeophyllum trabeum (Pers. ex Fr.) Murr
1973 - IRG/WP 113
T Hof
Some statistics on the Brazilian Wood Preservation Industry: 1980-81
1982 - IRG/WP 3214
Statistical data on the production of pressure treated wood and on the consumption of wood preservatives are given for the years of 1980 and 1981 in Brazil....
M S Cavalcante, F C Geraldo, A R De Freitas
Metal carboxylates for wood pest control
1996 - IRG/WP 96-30109
Metal carboxylates have been used as wood preservatives for more than fifty years. Predominantly salts of naphtenic acids have been commercially applied so far. They have water repellent as well as fungicidal and insecticidal properties. In the last years, metal carboxylates of saturated fatty acids were introduced. Fatty acids with 7-10 carbon atoms already have fungicidal activity by themselves....
F Pohleven, M Petric
Termite barriers for new construction
2000 - IRG/WP 00-10341
Subterranean termite protection in Australia has traditionally relied upon the creation of a zone of poisoned soil under and around the structure to prevent termite attack from the ground. The transition away from persistent soil poisons which began with the withdrawal of cyclodienes in 1995 provided market opportunities for innovative barrier systems. The new barrier systems currently being used ...
D M Ewart
Tunneling ability of subterranean termites through termiticide-treated soil
1988 - IRG/WP 1375
A test apparatus was designed to facilitate accurate measurement of termite penetration into termiticide-treated soil; three termiticides at 500 ppm were evaluated. Coptotermes formosanus Shiraki workers tunneled significantly farther into chlordane-treated soil than did Reticulitermes flavipes (Kollar). Both species only slightly penetrated chlorpyrifos-treated soil. Neither species penetrated so...
S C Jones
Migration of Metals from Douglas-fir Lumber Treated with ACZA or Pentachlorophenol Using Best Management Practices: Preliminary Tests
2005 - IRG/WP 05-50224-4
The potential for migration of preservative components from ammoniacal copper zinc arsenate (ACZA) and pentachlorophenol treated Douglas-fir lumber in non-soil contact exposure was assessed in a simulated rainfall device. Metal levels from ACZA treated wood were elevated for the first 30 minutes of rainfall and then declined sharply. Repeated cycles of rainfall led to declines in initial metal l...
J J Morrell, Hua Chen, J Simonsen
The use, approval and waste management of industrial wood preservatives. A preliminary report
1994 - IRG/WP 94-50033
The structure on the wood preservation through the world is heterogenous. Environmental legislation, approval policy and application practices differ in each geographical region and in individual countries. This preliminary report gives a rough estimation of the production of treated timber, the use of wood preservatives and a bief summary of environmental status of wood impregnation in selected c...
A J Nurmi
Disposal of treated wood - Canada
1990 - IRG/WP 3563
It is estimated that treated wood removed from service each year in Canada contains about 16,000 tonnes of creosote, 1000 tonnes of pentachlorophenol and 245 tonnes of CCA or ACA. The amount of CCA treated wood for disposal is expected to increase more than ten-fold by the year 2020. At present, most treated wood is disposed of in landfills, burned (creosote only) or recycled as other products. Ot...
P A Cooper
The leachability and specificity of the biological protection of timber using Scytalidium sp. and Trichoderma spp
1986 - IRG/WP 1302
The results of field experiments, using biological control against internal decay of creosoted poles, are briefly reviewed and the evidence concerning the leachability of the antibiotics produced by these species is presented. A pure culture miniblock decay test on biological control treated pine sapwood is described and the results compared to previously published data. The protection against Len...
P I Morris, N A Summers, D J Dickinson
Quality control of microwave treatment of timber after dry rot attack
2001 - IRG/WP 01-40205
In Denmark microwave treatment of timber has been used during the last 15 years for eradication of dry rot (Serpula lacrymans). About 1500 microwave treatments have been employed in coorporation with Hussvamp Laboratoriet. Previously all the infected timber was removed plus an extra metre as a safety zone. This meant that all casting boards and plaster had to be removed as well and joists replaced...
J Bech-Andersen, J Andreasson, S A Elborne
A risk model for termite attack in Australia
2003 - IRG/WP 03-10468
This paper describes a model to predict the risk of termite attack on a house in Australia. It is based on a survey of expert opinion and data from 5000 houses. The model gives a quantitative estimate of risk, and as such is useful for the development of risk management systems. An example of the application of such a system is given....
R H Leicester, C-H Wang, L J Cookson
Evaluation of termiticides in field trials
1990 - IRG/WP 3633
Termiticide-treated posts and stakes have been tested at the field test site in Kagoshima, Southern Kyushu, Japan. Various commercial and alternative termiticides have been evaluated annually as TAI (termite attack index), calculated by the equation: TAI = R x P, where R is the mean of attack rating of 0 (sound), 10 (sign of tasting), 30 (slight attack), 50 (moderate attack), 100 (severe attack), ...
M Takahashi, Y Imamura, K Tsunoda, A Adachi, K Nishimoto
Envelope treatment to protect softwood timbers from damage by subterranean termites
2003 - IRG/WP 03-30313
Two aboveground field trials were conducted in Australia to determine the effectiveness of envelope treatments of deltamethrin and permethrin for the protection of softwood framing timbers against termite damage. Radiata pine Pinus radiata D.Don and slash pine Pinus elliottii Englem., were treated with Tanalithä T (a novel solvent) to achieve 5-mm-depth envelopes. Details of a field trial against...
B C Peters, J W Creffield
Methods for testing fumigant efficacies against termites
1986 - IRG/WP 1297
Methodologies for testing fumigants against termites are reviewed and factors needed to be taken under consideration for standardization listed. Toxicity should be defined by both direct exposure to the gas and under more practical "barrier" conditions which include test enclosures simulating abiotic surroundings of the termites, i.e. wood, nest material, etc. To observe latent effects, mortality ...
N-Y Su, R H Scheffrahn
Report on biological control of decay in poles
1977 - IRG/WP 149
The following its a brief report on a preliminary experiment carried out for the United Kingdoms Midland Electricity Board during 1974-1975 to establish, under laboratory conditions, the potential controlling value of some non-decay fungi against Lentinus lepideus. Lentinus lepideus has been confirmed to be the commonest Basidiomycete causing decay in poles in the Boards area....
T A Oxley
Antagonistic effect of Trichoderma spp. against Serpula lacrymans in the soil treatment test
1991 - IRG/WP 1473
Soil treatment tests for preventing growth of Serpula lacrymans were conducted using Trichoderma spp. as antagonists. Soil specimens tested were Kanuma-soil without organic matter and the horticultural soil which was collected from the test site of the stake test. Perfect efficacy of treatment with Trichoderma spp. was shown when the horticultural soil without sterilization was used as a soil spec...
S Doi, A Yamada
Soil contamination at the wood preservation industry: Treatment technologies
2001 - IRG/WP 01-50166-16
The soil is a specific compartment of the biosphere, because it is not only a geochemical sink for contaminants, but it also acts as a natural buffer, controlling the transport of chemical elements and substances to the atmosphere, hydrosphere, and biota. Soil contamination problems are expected at wood preservation sites, particularly at those which use(d) inorganic wood preservatives or creosote...
A B Ribeiro, L M Ottosen
Comparative study of termite diversity in moist evergreen forest and dry evergreen forest, Chanthaburi province, Thailand
2003 - IRG/WP 03-10480
Sixty out of one hundred plots of two forest types (moist evergreen forest (MEF) and dry evergreen forest (DEF)) in Chanthaburi Province, eastern Thailand, were randomly surveyed for the presence of termites from all possible habitats. Three hundred and forty-five samples were collected from December 1999 – April 2000. Morphological identification of the 345 samples gave results for 3 families, ...
S Chutibhapakorn
Biological control of blue stain on wood with Pseudomonas cepacia 6253. Laboratory and field test
1989 - IRG/WP 1380
Pseudomonas cepacia strain 6253 was tested as a biological control agent on wood samples under laboratory conditions, as well as in the field. In the laboratory this bacterium controlled blue stain on Pinus radiata, but field test were not totally satisfactory. However, after 2 months of field test, the test samples were 1/3 to 1/2 less stained then the control samples....
R Benko
A method to evaluate the effeetiveness of bait application using a transferred nest of Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae)
1999 - IRG/WP 99-20161
Although a survey of monitoring stations can tell us the decline of termite activity after application of baits, it seems questionable to conclude an eradication of a Whole colony of subterranean termites if the termites move out their foraging territory. Only reliable method to ensure the success of bait application is to determine the absence of living termites in their nest in accordance with a...
K Tsunoda, T Yoshimura, H Matsuoka, Y Hikawa
Dimensional stability, biological resistance, and mechanical properties of phenol-resin-treated particleboard
1990 - IRG/WP 3622
Particleboards were treated with a low molecular-weight phenol-formaldehyde (PF) resin and their enhanced properties were evaluated. Besides dipping of particles in aqeous solutions of resin, and spraying of resin solutions before spray of the conventional phenol-formaldehyde resin for adhesive binder, one step treatment by spraying of the mixture of the low molecular-weight resin and the adhesive...
Y Imamura, H Kajita
Biological resistance of phenol-resin treated wood
1990 - IRG/WP 3602
Biological resistance of PF (phenol formaldehyde resin) - treated wood has been tested in relation to the resin properties, wood species and biological factors. When tested using water-soluble PF (mol. wt. 170), ca. 10% RI (resin impregnation) was enough to suppress the decay of Japanese cedar (Cryptomeria japonica) and western hemlock (Tsuga heterophylla) blocks exposed to Tyromyces palustris (br...
M Takahashi, Y Imamura
2nd IRGWP - Questionnaire on the state of pollution control in the field of wood preservation (Introductory letter)
1981 - IRG/WP 3184
H Willeitner
2nd IRGWP - Questionnaire on the state of pollution control in the field of wood preservation
1981 - IRG/WP 3185
H Willeitner