IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 41 documents. Displaying 25 entries per page.


In service performance of wood sound abatement barriers
2024 - IRG/WP 24-41006
Sound abatement barriers made form treated hem-fir in service near Vancouver, Canada were inspected after about 10-12 years in service. The barriers appeared in good condition and no boards were to the point of needing replacement. The sound abatement decibel readings at all locations indicate they perform as well as concrete barriers and exceed the 5 dBA regulatory requirement for noise reduction...
S Kus, D Wong, R Stirling


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Acoustic communication between Microcerotermes crassus Snyder
1982 - IRG/WP 1158
An unusual acoustic communication within a nest of Microcerotermes crassus SNYDER is reported. The signals produced by the termites are described and possible reasons for this behavior are considered....
U Kny


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Techniques for field assessment of particulate termite barriers
2000 - IRG/WP 00-10376
Field testing of particulate termite barriers poses problems different from those encountered when testing preservatives or soil termiticides. To ensure an adequate level of challenge, and minimise the risk of a Type II error, the experimental design must promote termite activity and provide a significant, readily detectable, food source which can only be reached by penetrating the test barrier. I...
D M Ewart, E R Rawlinson


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-40286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Wood in concrete. Summary of discussion at IRG 14, Surfers Paradise, Australia
1984 - IRG/WP 3264
The performance of untreated and preservative treated wood when placed in direct contact with concrete was considered in a discussion session at IRG 14. While published reports in this area are scarce, research is in progress internationally and a variety of practices are currently available to minimize any additional hazard posed by contact with concrete. This report summarizes the points raised ...
R J Murphy


Termite barriers for new construction
2000 - IRG/WP 00-10341
Subterranean termite protection in Australia has traditionally relied upon the creation of a zone of poisoned soil under and around the structure to prevent termite attack from the ground. The transition away from persistent soil poisons which began with the withdrawal of cyclodienes in 1995 provided market opportunities for innovative barrier systems. The new barrier systems currently being used ...
D M Ewart


Termite physical barriers: Update on retrofitting Granitgard around 'mock-up' buildings after three years
1995 - IRG/WP 95-10118
This field experiment was installed three years ago (March 1992) to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite aggregate or "screenings", as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and ...
B M Ahmed, J R J French


Physical properties variation of sound and top dying affected sundriwood (Heritiera fomes) in mangrove forest of Bangladesh
2004 - IRG/WP 04-10504
Top dying of sundri (Heritiera fomes Buch.-Ham.) in the Sundarbans is considered to be the most severe of all the diseases of tree crops in Bangladesh. The wood samples from sound, moderately affected and severely affected sundri trees from three different tree heights for every individual test were collected and their respective physical properties were examined to make a comparison. It was found...
S C Ghosh, A K M A Bosunia, M A Islam, A K Lahiry


Estimation of the population of a sound colony of Coptotermes lacteus (Froggatt)
1988 - IRG/WP 1353
Selecting an area with a high termite hazard is deemed essential in locating field sites in order to screen potential termiticides and wood preservatives. Yet, quantifying termite populations in such sites remains imprecise. There are major problems associated with estimating populations of termites in mound colonies (either free-standing or in trees), and these are briefly discussed. In this pape...
D M Ewart, J R J French


The effect of mortality diseases on wood quality of sissoo (Dalbergia sissoo Roxb)
2006 - IRG/WP 06-10569
Sissoo (Dalbergia sissoo Roxb.) is a lagre deciduos, fast growing, strong light demanding and leguminous tree specie. It is an important multipurpose specie widely being planted in the agro forestry and and social forestry pratices in Bangladesh, particularly in the north and south-western parts of the country. On account of its better quality, sissoo is valued as good as construction and utility ...
M M Islam, M O Hannan, G N M Ilias


The case for non-chemical termite barriers in termite control
1989 - IRG/WP 1381
A brief outline of current non-chemical barriers in subterranean termite control and their use in Australia is presented. Recent use of non-chemical barriers in Hawaii has led to their evaluation in termite control here and elsewhere. In Australia, preliminary laboratory and field experiments have shown similar results to those found against Coptotermes formosanus in Hawaii, namely, Australian Cop...
J R J French


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-20286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Termite physical barriers: Is retrofitting with Granitgard an option?
1993 - IRG/WP 93-40011
Granite particles within the range of 2.4 to 1.7 mm diameter were recently adopted by the Standards Association of Australia as an alternative treatment to soil chemical barriers in protecting new buildings against subterranean termites. The granite substrate is sold under the commercial name, "Granitgard". However, there are many existing buildings that have no chemical or physical subterranean t...
J R J French, B M Ahmed


New approaches to practical evaluation method of bio-degradation of wooden construction - Non-destructive detection of defects using radar technique
2000 - IRG/WP 00-20214
There have been a number of researches and developments on the techniques and apparatus for the nondestructive evaluation of the biological deterioration in wood and wooden constructions, such as decay or insect attack in house, public buildings or in historically important architectures. As for the detection of the decay in wood, techniques using sound in audible or in ultrasonic frequency ranges...
Y Fujii, Y Komatsu, Y Yanase, S Okumura, Y Imamura, M Tarumi, H Takiuchi, A Inai


Termite physical barriers: Update on retrofitting Granitgard around 'mock up' buildings after four years
1996 - IRG/WP 96-10140
This field experiment was installed four years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name, Granitgard, as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are ...
B M Ahmed, J R J French


Electricity pole treatments - Wedding Bells State Forest. Inspection September 1983
1985 - IRG/WP 3334
A survey to study the extent of soft rot in hardwood poles in N.S.W. was commenced in 1975. The results of the survey, published in 1982, indicated that a number of factors contributed towards soft rot attack on poles in service. A detailed rest on pole treatments and maintenance procedures was established in 1976, at a site in Wedding Bells State Forest near Coffs Harbour. The site selected was k...
R S Johnstone, R H Eldridge


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


List of fungi observed in avalanche barriers located in subalpine and alpine regions
1970 - IRG/WP 17
In the Subalpine region (Schilt-Stein; 1400-1500 m above sea level) the following fungi were observed: Basidiomycetes: Corticium alutaceum, Corticium ochraceum, Corticium sp., Collybia sp., Dacryomyces deliquescens, Exidia glandulosa, Lenzites abietina, Lenzites sepiaria, Lenzites trabea, Osmoporus odoratus, Peniophora pubera, Peniophora sp., Polystictus abietina, Poria placenta, Poria mucida, Po...
O Wälchli


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-40286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


An investigation of the nutritional physiology of the wood-boring weevil Euophryum confine Broun
1994 - IRG/WP 94-10082
The digestion of Picea abies Karst and Pinus sylvestris L. by Euophryum confine, at two sites is reported in this study. The composition of sound wood, wood from the heads of the weevil tunnels and the frass egested has been determined by gravimetric analysis. A comparison of sound wood and wood ingested showed that weevils tunnelled in microbially decayed wood, while a comparison of the wood inge...
A J Pitman, S M Cragg, G S Sawyer


Next Page