Contribution to study of the degradation caused in Pinus spp. poles used in field test
1989 - IRG/WP 1417
The study of the degradation produced by soil natural microflora on wood in contact with it in the field, has been going on for several years now. Our contribution to this aim in the present work has dealt with the possible relationship of the microorganisms in the soil. The microscopic visualization of wood colonization by the microorganisms, and the chemical analysis of the degraded wood compare...
M T De Troya, A Garcia, M J Pozuelo, A M Navarrete, A Cabanas


Are fungal cellar tests really necessary?
1989 - IRG/WP 2333
During the past decade the range of methodology used to evaluate wood preservative potential has significantly expanded. At the forefront of these new tools available to the scientist·is the fungal cellar. This technique, as currently applied, involves the exposure of treated and untreated samples to conditions of moisture and temperature which ensure optimum fungal attack. By comparison data wit...
J N R Ruddick


Assessment of losses of wood preservatives from treated wood by leaching into the environment
1993 - IRG/WP 93-50001-13
Wood preservative chemicals may be lost from treated timber by leaching into water or soil. The degree to which this might occur and its effect on the environment is difficult to assess quantitatively due to the absence of appropriate test methods. This paper describes work to assess test methodology capable of allowing the rates of loss of wood preservative from treated timber to be quantified. T...
R J Orsler, G E Holland


An in-ground natural durability field test of Australian timbers and exotic reference species. Part 2: Progress report after approximately 13 years' exposure
1983 - IRG/WP 1189
The condition of heartwood specimens of Australian and exotic timber species after approximately 13 years' in-ground exposure is given. Four of the 5 test sites have a termite hazard in addition to the hazard from a range of decay fungi. Values for specimen life are given only where all replicates of a timber species have become unserviceable. Results give evidence leading to doubt about ...
J D Thornton, G C Johnson, I W Saunders


Changes in the degree of decay of lignocellulosic substrate used in a screening test of fungicidal wood preservatives
1977 - IRG/WP 287
This report contains results of investigations aimed at: a) determination of the effect of the kind of substrate and species of test fungus on quantitative changes in used samples prepared from spruce cardboard, and b) comparison of the threshold fungicidal values of come fungicides determined with accelerated method, with values obtained by block method. During performed investigations, the metho...
K Lutomski


Preliminary results of investigations on screening test of chemical compounds suitable for the preservation of lignocellulosic materials against biodeterioration
1976 - IRG/WP 262
This paper investigates the possibilities of reducing the time needed for the determination of the effectiveness of chemical compounds from the point of view of their eventual application to lignocellulosic materials for preservation against decay and soft-rot....
K Lutomski, S S Neyman


IRG test of preservative-treated hardwoods with particular reference to soft rot. Report on condition of specimens installed in Victoria, Australia
1982 - IRG/WP 3207
J Beesley


Collaborative soft rot tests: Proposals for a standardized soil burial test
1971 - IRG/WP 201
A F Bravery


Mycological testing of plywood and board materials. Part 1: Review of information supplied by IRG members
1978 - IRG/WP 284
In December 1975 IRG members were asked for published information, information of current work in progress and views on mycological test methods for board materials. The object was to stimulate discussion and possibly establish a joint research effort within IRG in order to establish a meaningful test with reproducible results....
C R Coggins


The effectiveness test of chemicals against Serpula lacrymans
1984 - IRG/WP 2222
The effectiveness tests of wood preservatives against Serpula lacrymans were conducted in accordance with Japan Industrial Standard A 9302 and Japanese Wood Preserving Association Standard No. 1. Also, the soil treatment test against this fungus was carried out with two chemicals. The preservatives tested without Creosote oil (out of JIS) had sufficient preservative effect against Serpula lacryman...
S Doi


Utility, deterioration and preservation of marine timbers in India
2005 - IRG/WP 05-40314
Timber is extensively used in India in the marine environment for various purposes due to its several advantages over modern materials. Infact, its use is increasing in recent years, finding wider and wider applications and this scenario is not going to change in the near future. Though, the bio-deterioration problem is found very severe in tropical waters, still indigenous methods are widely empl...
B Tarakanadha, M V Rao, M Balaji, P K Aggarwal, K S Rao


Testing of termiticides in soil by a new laboratory method with regard to Phoxim for replacement of chlorinated hydrocarbons
1986 - IRG/WP 1292
In comparison to chlorinated hydrocarbons insecticides of the compound classes organophosphates, carbamates and pyrethroids were tested according to an earlier described soil-test in the laboratory. The following termite-species were used: Heterotermes indicola, Reticulitermes santonensis and in addition Reticulitermes flavipes, Reticulitermes lucifugus, Reticulitermes speratus and Coptotermes for...
R Pospischil


Testing of alkylammonium compounds
1981 - IRG/WP 2152
Following laboratory soil block tests which showed that Bardac 20 possessed a fungicidal threshold similar to that of chromated copper arsenate, treated ponderosa pine sapwood stakes were installed in a field test site near Vancouver, Canada. Two years after installation all the stakes show signs of fungal degradation. Seven stakes have been removed from the test due to total loss of strength afte...
J N R Ruddick


Austrian field test method for anti-sapstain chemicals
1994 - IRG/WP 94-20020
Although Austria is a small country, the annual consumption of anti-sapstain products ranks to approximately 500 tons annually. In 1994, only three products will be approved by the Austrian Wood Preservation Committee (AWPEC). There is demand for a field test method, which demonstrates the efficacy of an anti-sapstain product and consequently implies the acceptance and approval of product by the A...
R Gründlinger, M Brandstätter, H Melzer, O Janotta


Test procedure to determine the effect of timber substrate on the effectiveness of different preservatives in sea-wate
1975 - IRG/WP 414
R A Eaton


Resistance to soft rot of hardwood plywood treated with CCA salt
1983 - IRG/WP 3258
Plywood made from indigenous hardwoods was treated at an average loading of 34 kg Celcure A per m³ and was installed in a field test. After 20 years the samples were only slightly attacked by soft rot and the glue bonds were still intact....
R S Johnstone


Exterior weathering trials on radiata pine roofing shingles
1985 - IRG/WP 3240
A series of test roofs clad with radiata pine (Pinus radiata D. Don) shingles that had been pressure-treated with various water-borne preservative formulations were installed at a Forest Research Institute test site in Rotorua in 1977. A further series of test roofs installed in 1978 included radiata pine shingles pressure-treated with a commercial light organic solvent preservative (LOSP). Evalua...
D V Plackett, C M Chittenden, A F Preston


Moulds and indoor climate in Denmark
2003 - IRG/WP 03-10488
Just like in many other countries after the oil crisis in 1972 Danish houses were tightened with the result that the relative air humidity rose considerably. The Ministry of Energy also demanded a lowering of the indoor temperature from 25°C to 20°C with the result that the relative air humidity rose even more. According to the latest survey 10% of Danish buildings are infected with moulds. Moul...
J Bech-Andersen, S A Elborne


Proposals for a vermiculite burial soft rot test method
1980 - IRG/WP 283
J G Savory, J K Carey


A new ground-contact wide-spectrum organic wood preservative: DNBP
1986 - IRG/WP 3358
A new organic wood preservative, which 25 years field tests have proved to be of efficiency and effectiveness comparable to CCA wood preservatives for ground-contact applications, is presented. Physical and chemical tests, supporting the long term field test results as well as indicating the characteristics of this preservative, are also presented....
W E Conradie, A Pizzi


Rapport sur l'activité du CEN/TC 38
1983 - IRG/WP 2204
M Pottevin


Ecotoxicological risks of anti-sapstain preservatives washed off from treated timber
2000 - IRG/WP 00-50144
A field method for ecotoxicity assessment of rain water wash-off from anti-sapstain treated timber was developed. In the course of this study freshly sawn timber treated with 1.5% Busan 30 L (reference preservative) and a control stack with untreated pine were exposed to weathering. The run-off water was ecotoxicologically tested with organisms from three trophic levels (Vibrio fischeri, Kirchneri...
G Aschacher, R Gründlinger


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


Sequential exposure of borate treated Douglas-fir to multiple Formosan subterranean termite colonies in a 40-week field test
1993 - IRG/WP 93-10006
Douglas-fir boards (ca. 74.5 g) pressure-treated with disodium octaborate tetrahydrate (DOT) retentions of 0 (controls), 0.88, 1.23, 1.60, or 2.10% (weight/weight) DOT were sequentially exposed to four active field colonies of Formosan subterranean termites, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), in an above-ground field test. Samples were placed in contact with each colony fo...
J K Grace, R T Yamamoto


A direct basidiomycetes test methodology. Report on an EWPM ring test
1988 - IRG/WP 2306
Results of an EWPM-ring test using a direct basidiomycetes test methodology are reported. The test is caracterized by using big test blocks and infestation by infected wood under unsterile conditions. The test procedure needs further development work, but the results are so promising that co-operation with CEN and EHC is initiated with the purpose of recognition and standardization....
B Jensen