A field trial to assess the potential of antisapstain chemicals for long-term protection of sawn radiata pine
1986 - IRG/WP 3375
Seven chemical formulations were tested as antisapstain treatments for freshly sawn radiata pine sapwood (90x50 mm²). Each formulation was used with and without a water-repellent additive and was sprayed on to 1 m long boards. The boards were then stacked into "mini" packets and stored unprotected from the weather for 6 months. Haipen 50w (at 0.2 or 0.4% active) and NaPCP (1% active) plus 1.5% bo...
J A Drysdale


The effects of pH on leaching of copper-chrome-arsenate (CCA) from pressure-treated Kenyan-grown Eucalyptus saligna and Acacia mearnsii: Initial findings.
2002 - IRG/WP 02-30298
The effects of pH on leaching of CCA from pressure-treated Kenyan-grown Eucalyptus saligna and Acacia mearnsii were tested under laboratory conditions. Small samples of the two species (100mm x 30mm x 40mm) were smooth sawn from 8-year old trees to represent equal amounts of both sapwood and heartwood, air-dried to 12% moisture content, end-sealed, and pressure-treated at a commercial treatment p...
R Venkatasamy


Assessment of the biocontrol potential of a Trichoderma viride isolate in a field trial
1998 - IRG/WP 98-10252
A field trial has been set up near Dundee, to assess the biological control potential of a Trichoderma viride isolate T60. This isolate has been shown in laboratory tests to be particularly effective in protecting wood against certain basidiomycete decay fungi. Wood was treated with T60 spores using vacuum-pressure impregnation in a pilot preservation plant. Scots pine and Sitka spruce stakes wer...
H F Brown, A Bruce


Residual CCA levels in CCA treated poles removed from service
2000 - IRG/WP 00-50152
Fifty-two CCA treated poles removed from service after 1 - 50 years were sampled at different depths from their below ground and above ground zones and the preservative levels and mass balances related to the location in the pole and pole age. Generally CCA retentions were still well above the toxic threshold for decay in even the oldest poles. This confirms the good leach resistance of CCA and th...
P A Cooper, D Jeremic, J L Taylor


Minimisation of the Environmental Impacts of Coatings on Exterior Wood by Optimisation of their Life Spans
2003 - IRG/WP 03-50197
The study has shown that the environmental impacts from coatings on exterior wood are dependent criteria on their life spans. A minimisation of the environmental impacts can be performed with the help of the integrated design model, which is tested in this study. The optimal life spans, found as reference service lives from the exposure tests, statistical evaluation and the assessment of experts w...
L Strömberg


Leachability of active ingredients from some CCA treated and creosoted poles in service. A progress report after 10 years testing
1990 - IRG/WP 3627
CCA K33 TYPE B treated or creosoted poles, 10 pieces of each treatment type, have been monitored from the treatment plant to an electricity line, which was build up in Southern Finland in 1978. Preservative retention was determined by taking borings at four different levels: 1.5 m from the top end, 1 m above ground line, ground line and 0.5 m below ground. Determinations were made before setting u...
A J Nurmi


Social and economocal impact of an extension of service life resulting of an adequate preventive treatment. Application to wooden components used in urban areas with a high density of population
1993 - IRG/WP 93-50001-15
Le document évalue les problèmes rencontrés en zone urbaine pour le sauvetage des constructions: coordination de la lutte, délimination des chantieres et des périmètres d'investigation, nuisances causées par les interventions, risques pour la santé, risques pour l'environnement. Coûts. Comparaison socio-économique du traitement préventif et des interventions à posteri...
A T De Lelis, G A C Lopez


The results of detection on CCA components of the soils contacted with CCA-treated woods - A trial study for the availability of the burial Method as a disposal CCA treated wood waste
1993 - IRG/WP 93-50005
The objecteve of this experiment is to get a knowledge that, when CCA treated wood wastes were buried in a soil as a disposal, the soil would be or not be contaminated by the components of CCA preservatives in wood wastes. The specimens used were cutting logs and chips made of the CCA treated electric pole waste. The soil was buried to the 15 cm depth and the log specimens were set in the soil for...
K Suzuki, H Sonobe


Blue stain in timber in service. Progress review of Sub-group collaborative tests - 1981/82
1982 - IRG/WP 2178
Following from the discussions after reporting Document IRG/WP/2146 at the Meeting in Sarajevo, 1981, it was decided that 1.) more precise definition was needed of the artificial weathering schedules used in the work - participants to re-check Table 8 and send further details or amendments to Dr Bravery; 2.) a further test employing a wider range of chemicals was necessary using a smaller range of...
A F Bravery, D J Dickinson


Direct analysis from wood of the blue stain fungi Aureobasidium pullulans and Hormonema dematioides by denaturing gradient gel electrophoresis
2006 - IRG/WP 06-10595
Aureobasidium pullulans and Hormonema dematioides are the two organisms used in the EN 152 laboratory method for determining the effectiveness of preservatives against blue stain in service. The literature concerning the disfigurement of surface coatings and exposed timber in-service states that A. pullulans is the dominant blue stain fungus, due to its frequent isolation from stained material. In...
M J Ray, D J Dickinson


L-joint based testing for service life prediction of exterior plywood in out of ground contact conditions
2006 - IRG/WP 06-20342
Good biological performance of several plywood types in exterior conditions is most probably related to altered wood moisture behaviour compared to solid wood. Therefore a test set up was developed, using EN 330 L-joint testing methodology, to facilitate differentiation of plywood for exterior applications. The proposed test set up is an adaptation of an accelerated L-joint method introduced by V...
J De Smet, I De Windt, J Van Acker


How to win friends and influence the market — Service Life Prediction and performance-based durability assessments of wood products in construction
2006 - IRG/WP 06-20348
Due to direct and implied demands from the market and from e.g. the EU Construction Products Directive, the need to supply service life estimates for building products is growing. For several years, a development of Service Life Prediction (SLP) methodologies has been going on, but the awareness of this development has hitherto reached only a very limited extent in the wood sector. For materials w...
F Englund


One year performance of graveyard stakes in the Northern Territory of Australia
2006 - IRG/WP 06-30398
This paper presents the one year progress performance of in ground graveyard stakes exposed to numerous termite species and decay fungi in tropical field conditions. The field study examines the efficacy of a new timber preservative formulation developed at the University of Melbourne, Australia. The biocides used in the formulation are fipronil (a phenyl pyrazole) and trimethyl borate. The pre...
B Ahmed, J Hann, S Przewloka, P Vinden, P Blackwell, P Plews


Laboratory bioassay and field trial on imidacloprid and cypermethrin as glueline treatments for softwood plywood
2006 - IRG/WP 06-30405
The effectiveness of imidacloprid and cypermethrin as glueline treatments for protecting phenol formaldehyde (PF)-bonded Pinus radiata (radiata pine) plywood from attack by subterranean termites was evaluated both in the laboratory and field. Imidacloprid was evaluated in two plywood constructions (19 ply x 1.6 mm-thick veneers and 5 ply x 3.2 mm-thick veneers) whereas cypermethrin was evaluated i...
J W Creffield, D K Scown


A roadmap for performance-based specification of wooden components based on service life prediction
2007 - IRG/WP 07-20351
The need for an unified and harmonised system for performance classification and specification of wood and wood-based products in Europe emanates from requirements of users and the European Construction Products Directive, CPD. A road to a feasible specification system is outlined. Exposure-related performance prediction was worked out as a key task on the way to product specification. Therefore s...
C Brischke, A O Rapp


Service life prediction of plywood
2007 - IRG/WP 07-20367
Plywood is the wood based panel showing the best physical and mechanical properties for application under moist construction conditions. Appropriate physico-mechanical durability for exterior applications in transportation or construction systems can be guaranteed by assessment of the glue bond quality and mechanical characteristics. However, due to the fact that mainly non-durable wood species ar...
J Van Acker, J De Smet


Predicting the decay resistance of timber above-ground: 2. When can reliable field data be obtained?
2007 - IRG/WP 07-20368
Application of modern performance-based engineering and design requires building products that are thoroughly characterised in terms of their ability to perform as expected over time. The engineering community is attempting to use this information to provide predicted service-lives for various building elements. Increasingly, this service-life prediction must be based on objective measurement coup...
L P Francis, A J Swain, J J Morrell


Expected service life of outdoor wooden structures such as guard fences and noise barriers indicated by questionnaire survey
2007 - IRG/WP 07-20372
Forestry Agency, Japan has intended to expand the utilization of domestic wood in many areas such as not only housing constructions also outdoor structures. In order to respond the policy, actual durability and service life of these structures should be clarified, and the guide line for archiving planned service life also should be established. Japan Wood Preservers Industries Association carried ...
K Yamamoto, A Makita, A Yamaguchi, T Shiraishi, K Maeda, D Tezuka, S Katsumata, M Higaki


Tropical In-Ground Durability of CCB-treated Keruing and other Structural Sarawak Timbers after 8 – 10 Years Exposure
2007 - IRG/WP 07-30439
The heartwood of 12 mainly low-durability native timber species of Sarawak [4 Dipterocarpus (Keruing) species, Anisoptera grossivenia (Mersawa kunyit), Canarium apertum (Seladah), Dacryodes incurvata (Seladah laut), Dryobalanops oblongifolia (Kapur kelansau), Mesua macrantha (Mergasing), Podocarpus micropedunculatus (Kayu cina), Shorea compressa (Engkabang langgai), and Pterospermum javanicum (Ba...
A H H Wong, Ling Wang Choon


Variation of commercial timbers from Turkey in resistance to marine borers as assessed by marine trial and laboratory screening
2008 - IRG/WP 08-10668
Commercial timbers from Turkey used in coastal construction and boat building were tested for their resistance to marine wood-boring invertebrates in a marine trial and in a laboratory screening test. The timbers tested were beech (Fagus orientalis), oak (Quercus petraea), chestnut (Castanea sativa) and Scots pine (Pinus sylvestris). The marine trial was conducted over a period of 5 months at Mers...
H Sivrikaya, S M Cragg, L M S Borges


Field Trial of Copper Treated Moso Bamboo in Southern China
2008 - IRG/WP 08-30455
The field trial of moso bamboo treated by 9 copper preservatives for 5 years in Guangzhou was conducted in the paper. The result shown that: two ammonia based copper azole formulations F17/F18 and 1 amine copper formulation with boron F10, as well as 2 ammonia based ACQ, at the copper retention of 3.2 kg/m3 or above, have good resistant for decay and fine resistant for termites after 5 year field ...
Mingliang Jiang


In-service performance of wood depends upon the critical in-situ conditions. Case studies.
2008 - IRG/WP 08-20382
Wood is a unique building material, but is by nature designed to deteriorate. A detailed understanding of the factors and interactions involved are important when working with service life prediction of wooden components in buildings. Wood may experience exponential fungal degradation caused by variation in the climatic factors within a small limited area and by minor imperfection in the wooden ...
L Ross Gobakken, J Mattsson, G Alfredsen


Field Liners as physical barriers to prevent wooden utility pole decay in soil: An accelerated field simulation trial
2008 - IRG/WP 08-20384
Field Liners (FL’s), plastic sleeves used to protect in-ground wooden poles from fungal and termite damage, have been tested before as physical barriers to prevent contact between soil and wood and to retain wood preservative treatment. These earlier studies concentrated mostly on creosote preserved poles and early generation FL’s which were cumbersome in their application. The newer generatio...
A R Howgrave-Graham, L J Cookson, T Hale


Service life prediction of wood: scale-dependent tools within a bio-engineering framework
2008 - IRG/WP 08-20387
Service life prediction (SLP) is a complex yet essential method for the building industry. Accurate and precise assessment of the components is crucial for a strong position of wood on the market. As it is a biological material, wood has an inherent variability and is susceptible to fungal attack. Therefore a profound knowledge of these characteristics is the corner stone of SLP for wood products....
J Van den Bulcke, J Van Acker, M Stevens


Soft Rot Determines Service Life of L-joints with Low Borate Loading
2008 - IRG/WP 08-30470
As part of a research program on the potential use of borates by the Canadian wood products industry, Forintek set up an L-joint test of untreated and borate-diffusion treated hem-fir (western hemlock and amabilis fir) in 1990. The treated material had a low initial retention of only 0.2% boric acid equivalent and analysis after 5 years revealed no detectable borate close to the tenon. Nev...
P I Morris, J Wang, J K Ingram


Previous Page | Next Page