The resistance of composite boards protected with azole and inorganic nanoparticles to basidiomycetes and moulds
2015 - IRG/WP 15-40688
This paper presents a study on the resistance of wood composite boards, glued with silicone adhesive and obtained from chips of Scots pine Pinus silvestris L. and willow Salix viminalis L., to basidiomycetes and mould. The boards were protected in the production processes with fungicides based on metal nanoparticles, as well as on derivatives of 1,2,4-triazole, benzimidazole, and thiazole. The bio...
J Zabielska-Matejuk, I Frąckowiak, A Stangierska


Increasing the hardness of wood-composite panels by nanosilver
2016 - IRG/WP 16-40715
Effect of silver nanoparticles on hardness in medium-density fiberboard (MDF) was studied here. A 400 ppm aqueous nanosilver suspension was used at three consumption levels of 100, 150, and 200 mL/kg, based on the dry weight of wood fibers; the results were then compared with the control panels. The size range of silver nanoparticles was 30-80 nm. Composite mats were hot-pressed for 6, 8, and 10 m...
H R Taghiyari, J Norton, K Heidarhaee


Effect of Nano-Silane on Permeability in MDF as a Result of Susceptibility to Moulds and Fungi
2016 - IRG/WP 16-40716
Effects were studied of vapor chamber on specific gas permeability of nanosilane-treated medium-density fiberboards (MDF). Size range of nanoparticles was 20 – 80 nm. Nano-silane (NS) was used at four consumption levels of 0, 50, 100, and 150 g/kg dry wood fibers. Density of all treatments was kept constant at 0.67 g/cm3. Specimens were kept for 18 weeks in vaporized chamber; their specific gas ...
H R Taghiyari, J Norton, A Moradiyan, M Sadegh Taher Tolou Del, H Siahposht, B Moradi-Malek, M Noferesti


Underground timber constructions from the First World War are well preserved after 100 years
2017 - IRG/WP 17-10897
During the Great War or World War I many underground constructions have been built for protection from shelling. They were an important part of the trench warfare as they were used as an area to rest and carry out other activities such as eating. They would usually range in size from smaller constructions that could hold several men to larger entities that could hold thousands of soldiers. In the ...
J Van Acker, I De Windt, K Haneca, H Beeckman, F Claeys, S Vandenbussche, J Vandewalle, N Robeyst, A Willems


Long-time efficacy of some soil termiticides tested according to “Modified Ground Board Test”
2018 - IRG/WP 18-10935
Field trials of efficacy of soil termiticides available in Thailand were started back in the 1980s at four different locations representing different unique weather types of the country. The method used in the trials (Modified Ground Board Test) is the compulsory test for every soil termiticides aiming to be registered for termite control in Thailand. The ongoing record reveals that some particula...
C Vongkaluang, K Charoenkrung, N Same Rain


The Structural Performance of the Nail Driven into the Decayed Wood
2019 - IRG/WP 19-20652
In late years there are many actions to long-term excellent house realization. We have to consider repair or reinforcement for long-term and safety use of wooden house. There are various studies focused on structural performance of decayed wood. It is important for long-term use of wooden house that structural performance of nailed joint on decayed wood is accurately evaluated. However, there are ...
N Wada, H Isiyama


Assessment of the Material Durability and Structural Integrity of the Wooden Velodrome in Češča vas, Slovenia
2023 - IRG/WP 23-11012
Wood is a widely used material in the construction industry, and it has been utilized for thousands of years to create buildings and other structures. When wooden structures are designed, built, and maintained properly, they can be safe and long-lasting. Sports facilities, which provide athletes with a space to train, compete, and improve their abilities, are crucial in creating a strong and susta...
D Kržišnik, M Humar, B Lesar


What products are architects using? Relationships between deterioration part and structural performance in wooden houses
2023 - IRG/WP 23-50374
Architects work in the development of ideas around buildings and all the nuclei where human activity is generated. It is a work of organization of matter, in time and space, where the conceptual world of ideas and the aspirations of inventions, the interior world interact with the exterior in many kinds of realities. But as architects, we have always been interested in why and how things have bee...
I de las Casas


Relationships between deterioration part and structural performance in wooden houses
2023 - IRG/WP 23-50376
Based on the survey examples, there are four patterns of deterioration that tend to occur in plywood bearing walls of wooden houses in Japan. The first is a pattern in which wall is in a whole deterioration. It is a no damage wall or test specimen. The second is a pattern in which only the sill is deteriorating. It is caused by moisture or termites from ground to the base. In addition, there is a ...
Y Ota, H Ishiyama, S Okamoto


Fungicidal properties of black liquor from the waste MDF board digestion in terms of wood protection
2023 - IRG/WP 23-50379
The aim of the work was to determine the fungicidal properties of black liquor as a product of the chemical digestion of waste MDF board. The resistance of wood treated with black liquor from MDF waste pulping process was compared with the resistance of wood treated with black liquor from the pulping process of a by-product from agricultural production. The control material consisted of non-treate...
B Mazela, W Perdoch, A Szulc, I Sieminska


Towards a microactuator-sensing network for the structural health monitoring of wood
2023 - IRG/WP 23-50380
Timber structures decay over time with degradation in their structural integrity. Changing environmental conditions, varying loads, exposure to moisture or insect attacks lead to changes in their vibrational response behaviour. Here we present a low-cost device used as a triggered exciter to enable the monitoring of the structural integrity of timber bearers or even power poles in electricity netw...
S Oberst, S Sepehrirahnama, C Nerse, Z Brodzeli, J C S Lai, M Mankowski, T Atkinson, R Arango, G Kirker, T Evans