IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 246 documents. Displaying 25 entries per page.


Laboratory evaluation of the termiticidal effectiveness of TanalithÒ 3485
1995 - IRG/WP 95-10109
The termiticidal effectiveness of the copper azole TANALITH 3485 was evaluated with the benchmark preservative TANALITH C in a laboratory bioassay using two species of subterranean termites, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Retentions of TANALITH 3485 tested were 0.15, 0.24, 0.285 and 0.40% m/m Cu and for TANALITH C 0.025, 0.05, 0.08 and 0.095% m/m Cu. Un...
J W Creffield, J A Drysdale, N Chew, N-K Nguyen


Properties-enhanced albizzia particleboards by incorporating fungicide and insecticide in the glue
1994 - IRG/WP 94-30060
Preservative-treated particleboards were prepared by using tropical fast-growing albizzia and adding fungicides and insecticides to the adhesive-glue. the physical and biological properties of these boards were evaluated. No significant reduction in bending or internal-bond strength due to incorporation of the chemicals was detected. Treated particleboards effectively resisted attack by Coptoterme...
B Subiyanto, S Yusuf, Y Imamura, S Fushiki, T Saito, T Katuzawa


Performance of Two Imidacloprid-Treated Malaysian Hardwoods in an Accelerated Aboveground Termite Test
2005 - IRG/WP 05-30389
The performance of the chloronicotinyl insecticide imidacloprid as a wood protecting termiticide, under a simulated Malaysian biological hazard class H2 (exposure aboveground indoors against termites and wood borers), was evaluated by a novel termite field test protocol. Replicate end-grain sealed air dried test blocks (20 x 20 x 20 mm) of two Malaysian hardwoods, Kembang Semangkok (Scaphium spp.)...
A H H Wong


Termite physical barriers: Update on retrofitting Granitgard around 'mock up' buildings after four years
1996 - IRG/WP 96-10140
This field experiment was installed four years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name, Granitgard, as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are ...
B M Ahmed, J R J French


Antifeedant activities of flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki
1999 - IRG/WP 99-10305
Antifeedant activities of some flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki were examined with no-choice and two-choice tests. The activities of these compounds were considered in relation to their chemical structures. All flavonoids tested showed antifeedant activities whereas catechinic acid without A-ring and pyran ring in the molecule ...
W Ohmura, S Doi, M Aoyama, S Ohara


Changes in fat and moisture contents, and nitrogen fixation in laboratory maintained termites
1984 - IRG/WP 1242
Orphaned groups of termites of Coptotermes acinaciformis and Mastotermes darwiniensis were maintained in the laboratory for several months on two dietary regimes, and changes in their fat contents, moisture contents and nitrogen fixation rates were examined. There were no significant feed or feed time effects for either species. For Coptotermes acinaciformis, there was a highly significant time ef...
J R J French, P J Robinson, L G Turner, P J Pahl


Laboratory Evaluation of the Formosan Subterranean Termite Resistance of Borate-treated Rubberwood Chipboard
2004 - IRG/WP 04-30359
Both no-choice and two-choice 4-week AWPA laboratory tests were performed to evaluate the resistance of borate-treated rubberwood (Hevea brasiliensis) chipboard prepared from a commercial mill run, against the Formosan subterranean termite Coptotermes formosanus. Boric acid (technical granular) was incorporated into the boards during manufacture to achieve loadings of 1.0% or 1.1% boric acid equiv...
A H H Wong, J K Grace


Depth of foraging of subterranean termites in tropical Australia
1996 - IRG/WP 96-10141
Stakes of radiata pine (Pinus radiata D.Don) of varying lengths to 800 mm were inserted vertically in the soil with all but their lower 100 mm sheathed in a capped UPVC tube representing a physical barrier to termites. In one series of trials, termites were encouraged to aggregate at the upper ends of the tubes, in order to determine whether they would descend to the lower end of the barrier. In a...
L R Miller, M Hoschke, M Neal


Estimates of wood-consumption rates by termites
1983 - IRG/WP 1201
Effects of 2 components; termite-biomass and experiment duration on estimates of wood-consumption rates (mg wood/g termite/day), were examined. Three models; (1) no mortality, (2) linear mortality and (3) nonlinear mortality were used to calculate mean standing-crop biomass of termites. Model (1) predicted a significantly lower wood-consumption rate than those based on models (2) and (3). No signi...
N-Y Su, J P La Fage


Termite resistance of twenty-eight Indonesian timbers
1982 - IRG/WP 1150
A comparative study of termite resistance of 28 Indonesian wood species has been conducted using small samples measuring 5 x 10 x 20 mm³. The drywood termite Cryptotermes cynocephallus (Kalotermitidae) and the subterranean termite Coptotermes curvignathus (Rhinotermitidae) were used in the study. A resistance classification was derived on the basis of cluster analysis. The result reveals that Alb...
Nana Supriana, P E Howse


Performance of Borate-treated lumber in a four-year, above-ground termite field test in Hawaii
2001 - IRG/WP 01-30265
We report the fourth year of field study results from a protected above-ground field test in Hawaii simulating the sill plate (dodai) used in conventional Japanese housing construction. Field tests were established in both Hawaii and Japan to examine the efficacy of disodium octaborate tetrahydrate (DOT, 2% and 3% shell and through) wood treatments. In Hawaii, chromated copper arsenate (CCA, 4 kg/...
J K Grace, R J Oshiro, A Byrne, P I Morris, K Tsunoda


Assessment of untreated Papua New Guinea timbers against subterranean termites. Progress report 2
1993 - IRG/WP 93-10040
Eight species of Papua New Guinea wood including Kwila (Intsia palembanica), Taun (Pometia pinnata), Malas (Homalium foetidum), PNG Walnut (Dracontomelon dao), Calophyllum (Calophyllum sp.), Kamarere (Eucalyptus deglupta), PNG Beech (Nothofagus spp.) and White Cheesewood (Alstonia scholaris) were exposed groun contact for their natural durability against subterranean termites. Inspection after 42 ...
M Rokova, H C Konabe


Six-year Report on the Performance of Borate-treated Lumber in an Above-ground Termite Field Test in Hawaii
2004 - IRG/WP 04-30343
We report the fifth and sixth years of field study results from a protected above-ground field test in Hawaii simulating the sill plate (dodai) used in conventional Japanese housing construction. Field tests were established in both Hawaii and Japan to examine the efficacy of disodium octaborate tetrahydrate (DOT, 2% and 3% BAE shell and through) wood treatments. In Hawaii, chromated copper arsen...
J K Grace, A Byrne, P I Morris, K Tsunoda


Remedial wood preservative efficacy of BORA-CARE against the Formosan subterranean termite and eastern subterranean termite (Isoptera: Rhinotermitidae)
1991 - IRG/WP 1504
When a spruce board (3.8 cm x 8.8 cm x 2.4 m) was surface-sprayed with BORA-CARETM solution (containing 23% disodium octaborate tetrahydrate) and stored in an air-conditioned room (24 ± 2°C and 60 ± 5% RH) for eight months, ca. 40% of the wood (measured by the cross section surface proportion) contained borates at the rate of >2,500 ppm BAE (boric acid equivalent). In a choice bioassay, term...
N-Y Su, R H Scheffrahn


Termite field evaluations in hawaii: A brief review of methods and issues
1995 - IRG/WP 95-10131
The severe termite hazard in Hawaii, principally due to the presence of the Formosan subterranean termite (Coptotermes formosanus Shiraki), has long required the use of preservative-treated lumber in building construction. This hazard has also favored and stimulated field research in Hawaii on methods of protection from termite attack, including evaluation of soil insecticides and treated wood und...
J K Grace


Silafluofen: Novel chemistry and versatility for termite control
1995 - IRG/WP 95-30069
A novel silicon - containing insectizide, HOE 084498 ('Silafluofen'), with a favourable toxicological profile, has shown activity against a broad spectrum of agricultural and environmental health pests. Results from laboratory and field studies around the world have demonstrated that silafluofen is effective at protecting timber from attack by various species of termite and wood-...
A J Adams, A Jermannaud, M-M Serment


Standard principles of testing termiticides: A discussion paper
1991 - IRG/WP 1502
Recent restrictions and banning of termiticides such as organochlorines in some countries has focussed attention on the need for new and novel compounds as termiticides. However, this poses problems for both wood preservative manufacturers and termitologists. Test procedures have to be devised to evaluate the new termiticides so that the tests are practical, encourage vigorous termite activity, an...
J R J French


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Termite resistance classification of some tropical and temperate species based on the laboratory choice test results against formosan termite, Coptotermes formosanu
2004 - IRG/WP 04-20291
The results of classification of termite durability were varied. We carried out laboratory evaluation of the classification of termite durability on various species by the choice test against formosan termite, Coptotermes formosanus. We classified five grades (very sensitive to very resistant). According to our results, azobe, ipe, keruing, intsia, kapur, yellow meranti, jarraah, malas, cypres...
K Suzuki


Gaseous treatment of timber with allyl isothiocyanate. Fungicidal and insecticidal effects
1996 - IRG/WP 96-30108
Gaseous treatment with allyl isothiocyanate (AIT) was tested for its effects on the growth of microorganisms on the wood substrate and the mortality of subterranean termites and powder-post beetles. Toxic limits of AIT were determined as concentrations in the air when an AIT-treated filter paper was placed in a sealed container with fungus-inoculated wood specimens. Those were <3.8 ppm for Aure...
K Tsunoda, T Yoshimura


Implications for comparability of laboratory experiments revealed in studies on the effects of population density on the vigour in groups of Coptotermes lacteus (Frogatt) and Nasutitermes exitiosus(Hill) (Isoptera: Rhinotermitidae, Termitidae)
1983 - IRG/WP 1194
The vigour - survival. and wood consumption - of groups of Coptotermes lacteus and Nasutitermes exitiosus was measured when termites were kept at different population densities (g termites/mL) by changing group size and/or volume of the holding container. A characteristic pattern emerges for subterranean-like termite species. At low population densities (<0.01 g/mL) performance of termites impr...
M Lenz, R A Barrett, E R Williams


A study on the effectiveness of didecyldimethylammonium chloride to protect wood from attack by termites
1993 - IRG/WP 93-30009
A laboratory bioassay was conducted on the ability of didecyldimethylammonium chloride (DDAC) to protect Pinus radiata D.Don wood specimens from attack by two of Australia&apos;s most economically important species of subterranean termite, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Sapwood specimens of Pinus radiata, treated to achieve nominal retentions of 0.5...
J W Creffield


Report on the efficacy and performance of the insecticide candidate termiticide in H2 field trials
2004 - IRG/WP 04-10516
This paper explains the field results of phenol pyrazole treated timber against in an above ground mound colonies of Coptotermes acinaciformis (Froggatt). C. acinaciformis (‘termites’) are the major pest of human structures throughout tropical and sub tropical regions, causing billions of dollars in damage to timber-in-service worldwide. The result of this field test have shown that candidate ...
B M Ahmed, P Vinden, J Hann, J R J French


Is termite body size correlated with colony vigor?
1995 - IRG/WP 95-10130
Folk wisdom among termite researchers holds that the average body size (mass) of workers in a subterranean termite colony (Rhinotermitidae) is associated with the age and/or vigor of the colony. In particular, extremely large individuals are frequently thought to indicate a very old, or senescent, termite colony. However, there are very little data to support this assumption. It is also difficult ...
J K Grace, R T Yamamoto, M Tamashiro


Termite likes steamed larch wood
1995 - IRG/WP 95-10113
Steamed wood of Japanese larch (Larix leptolepis (Sieb. et Zucc.) Gord.) was preferably attacked by termites. Steam treatments have often been applied to Japanese larch wood for improving its penetrability or color. For preventing termite attack on steamed timber, we have to elucidate why termite likes it. Choice tests with Coptotermes formosanus Shiraki were conducted using larch boards steamed f...
S Doi, M Kubota, M Takahashi, T Yoshimura, A Adachi


Previous Page | Next Page