IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 927 documents. Displaying 25 entries per page.


Report on the efficacy and performance of the insecticide candidate termiticide in H2 field trials
2004 - IRG/WP 04-10516
This paper explains the field results of phenol pyrazole treated timber against in an above ground mound colonies of Coptotermes acinaciformis (Froggatt). C. acinaciformis (‘termites’) are the major pest of human structures throughout tropical and sub tropical regions, causing billions of dollars in damage to timber-in-service worldwide. The result of this field test have shown that candidate ...
B M Ahmed, P Vinden, J Hann, J R J French


New methods for nondestructive inspection of timber in buildings
1995 - IRG/WP 95-20070
In these years older buildings are renewed in most European countries on a large scale, and new techniques are needed for both inspection and eradication of fungal attacks. Heat treatment as a means of eradicating the dry rot fungus has been used in Denmark during the last decade. This technique minimises the structural damage to the building, whilst at the same time reducing costs by up to 50%. T...
B Madsen, O V Frederiksen


Evaluation of bending strength by non-destructive methods of Ezomatzu with white pocket rot
1991 - IRG/WP 2371
The possibility of application of three non-destructive methods was examined for evaluation of bending strength of ezomatsu (Picea jezoensis CARR.) with white pocket rot. As non-destructive methods, the measurements of ultrasonic wave propagation time, impact-induced stress wave propagation time and penetration depth of pin of "PILODYN Wood Tester" were applied to compare with visual evaluation of...
T Tanaka


Comparison of the in-ground performance of pigment emulsified creosote (PEC) and high temperature creosote (HTC)
2000 - IRG/WP 00-30217
A long-term field trial was conducted in Australia to compare the in-ground performance of two oil-borne preservative formulations, conventional high temperature creosote (HTC) and a modified creosote formulation, pigment emulsified creosote (PEC). Three retentions (50, 100 and 200 kg/m³) were targeted for each formulation. An additional retention of PEC formulation (308 kg/m³), which contained ...
J W Creffield, H Greaves, N Chew, N K Nguyen


Environmentally benign wood preservatives based on organic biocide antioxidant combinations: A brief review of laboratory and field exposure results and discussion of a proposed mechanism
2004 - IRG/WP 04-30335
The combination of various organic biocides with commercial antioxidants generally increased the biocides’ efficacy 2-3 fold against wood-destroying fungi in short-term laboratory decay tests, and some positive results have been obtained after 2-4 years of outdoor exposure. The two antioxidants principally examined, propyl gallate and butylated hydroxytoluene, are low cost and, since both are f...
T Schultz, D D Nicholas, W Henry, C Pittman, D Wipf, B Goodell


Development of a mini-block test method for the rapid evaluation of preservative performance against Basidiomycte fungi
1991 - IRG/WP 2379
Screening procedures for new biocides used as wood preservatives can be a time consuming process using conventional Basidiomycete assay procedures. This is due mainly to the long exposure periods required to achieve adequate levels of decay (weight loss) in the test blocks. A number of alternative methods have been developed but most utilise artificial substrates such as filter paper or agar in wh...
J Brown, S Caswell, G R Williams


Performance of copper-chrome formulations in ground contact in five test sites in New Zealand
1996 - IRG/WP 96-30113
Copper-chrome-arsenate (CCA), copper-chrome-boron (CCB), copper-chrome-fluoride (CCF) and copper-chrome-phosphate (CCP) have been tested at four retentions each in ground contact (25 x 50 x 500 mm³ radiata pine sapwood stakes) for 16 years in five test sites in New Zealand. Results to date show that test site characteristics have a marked effect on relative performance. In a warm and wet site (an...
M E Hedley, R N Wakeling, J Foster, B E Patterson


In ground performance of wood treated with a substituted isothiazolone
1990 - IRG/WP 3612
Isothiazolones (I.T.A.'s) are a class of biocides that have potential for use as wood preservatives. The substituted ITA, RH-287, (4,5,dichloro-2-n-octyl-isothiazolone-3-one) is being evaluated as a broad spectrum wood preservative. The evaluation program includes in ground stake tests which were established at two test sites in Mississippi, USA The tests used southern yellow pine treated...
L E Leightley, D D Nicholas


Preliminary results from the field experiment to determine the performance of preservative treated hardwoods with particular reference to soft rot. The four reference timber
1980 - IRG/WP 3164
The results given in the Tables 1-4 each refer to one of the four reference species treated with four solution concentrations of CCA as recorded from each test site. The species are: Alstonia scholaris, Betula pendula, Fagus sylvatica, Pinus sylvestris. The treatments were: Untreated, 0.66% CCA, 1.53% CCA, 3.01% CCA, 5.60% CCA. Each figure is an average of the ratings recorded for each replicate o...
J F Levy, D J Dickinson


Performance of Borate-Treated Wood Against Reticulitermes flavipes in Above-Ground Protected Conditions
2003 - IRG/WP 03-30309
Termites cause economically significant damage in Canada only in a few localized areas. However, one of those is in Canada’s largest city, Toronto, Ontario. In 1996, a test was set up of borate-treated lumber above ground, protected from rain but exposed to subterranean termites (Reticulitermes flavipes) in Kincardine Ontario. The material included western hemlock and amabilis fir lumber trea...
P I Morris, J K Grace, K Tsunoda, A Byrne


Hardwood Field Experiment: Progress Report 1977-1986
1986 - IRG/WP 3391
The international hardwood field experiment was planned in l976 and set up in same 30 different sites around the world. The test stakes include 4 reference species common to each site and in most cases at least 2 species of local importance. It was hoped that a picture of performance of a range of economically important species would be built up and at the same time provide vital background inform...
D J Dickinson, S M Gray


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Leaching from field test stakes. Part 2: The distribution in and leaching from different parts of test stakes
1994 - IRG/WP 94-50026
Field test stakes treated with Boliden K33 (copper, chromium and arsenic) and Cuprinol Tryck (CT86) (copper and N-alkylbenzyldimethylammoniumchloride) respectively were exposed in ground contact at two different test fields in Sweden and rejected due to decay after 2 to 28 years. Stakes treated with the same preservatives were also exposed during 7 years above ground. The test stakes have been ana...
F G Evans, B Nossen, M-L Edlund


Chemical Analysis of Southern Pine Pole Stubs Thirteen Months Following Treatment with Three Methylisothiocyanate Based Commercial Fumigants
2002 - IRG/WP 02-30294
Agricultural fumigants have been commercially used in the United States for over 20 years to control internal decay in utility poles and other wooden structures. Of the four fumigants which are currently used in the remedial treatment of utility poles, three are based on methylisothiocyanate (MITC) as being the principal fungitoxic component. Two of these MITC based fumigants, liquid metham sodi...
R J Ziobro, T C Anderson, D J Herdman, J Guzzetta, T Pope


Stake test with ammoniacal copper in combination with different agents started in 1962
1997 - IRG/WP 97-30130
In 1962 a stake test was started with ammoniacal copper in combination with chromium, arsenic, pentachlorophenol, boron, salicylic acid, benzoic acid, sorbic acid, pyridine and tannin. Different concentrations of the copper component were used as well as the added agents. For each concentration and test site, ten stakes of Pinus sylvestris L. sapwood were treated. The stakes were set out at two te...
B Häger, Ö Bergman


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Comments on leaching in view of accelerated testing
1977 - IRG/WP 294
We developed an accelerated test for leaching at elevated temperatures (75-85°C). This test was used for the examination of 11 preservative formulations containing Cu, Zn and As. The data obtained from these experiments were compared with data on some formulations tested by ASTM standard leaching test. The method consists in making a large surface to volume ratio of wood from a treated block by c...
J Rak


A case for ecosystem-level experimentation - A discussion paper
1986 - IRG/WP 1296
Although laboratory bioassays provide a first step in testing for potential termiticides and assist in formulating recommendations of these chemicals for regulatory agencies and users, they are not designed for predicting effects on natural populations (including humans) and on ecosystem-level features. To overcome this we need microcosm studies, carefully controlled experimental manipulations of ...
J R J French


Field study: Wood degradation pattern in buildings and utility poles in tropical climates of Nigeria
1992 - IRG/WP 92-1521
The paper is the result of five years field study of wood degradation patterns in three ecological forest zones (Guinea Savannah, Tropical rain forest and mangrove forest zones, respectively). It involved 800 residential buildings and 700 electric overhead transmission poles. The methodology used was a modified Eslyn (6) test. A high rate of Ascomycetes and Basidiomycetes attack especially on the ...
E O Onuorah


Effect of post-treatment drying schedule on the modulus of elasticity of CCA-treated southern pine dimension stock using nondestructive methods
1987 - IRG/WP 3413
This paper describes the results from the nondestructive testing for modulus of elasticity (MOE) of southern pine (Pinus sp.) 2 x 6's treated with chromated copper arsenate and redried using three commercial kiln schedules. The data indicate that redrying CCA-treated southern pine dimension stock treated to above-ground retentions (4 kg/m³) has no deleterious effect on the MOE, regardles...
H M Barnes, S Moore


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


Determination of corrosive effect of liquid wood preservatives to metals – First experiences with a National Standard which is in revision
2006 - IRG/WP 06-20321
The development of standards is an essential tool to characterise different kind of materials and products. An important aspect during the development of a new product is to check the corrosion behaviour with other materials. Corrosion can cause several problems like pitting corrosion. Consequently the knowledge concerning the corrosive effect of liquid wood preservatives is important due to the s...
E Melcher


The natural durability of five Indonesian timber species against marine borers - A field test in Indonesia
1981 - IRG/WP 474
This paper presents results of a natural durability field test using five species of Indonesian timbers against marine borers. An attempt is also made to assess any difference in durability between the lower and upper part of the trunks. Results of marine fungal identification, soft-rot assessment, and marine-borer assessment of CCA-treated test blocks will be reported in separate papers...
Suhirman, R A Eaton


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Method of embedding and staining of wood after biological testing to support the identification of decay type
1998 - IRG/WP 98-20131
A method for preparing wood for microscopic analysis after decay testing is described, with special regard to a novel fast simultaneous staining, which helps to identify different types of decay. The novel staining process is explained as well as the embedding of heavily decayed samples in polyethylene glycol (PEG) and picking up of sections by transparent adhesive tape. Special feature of the int...
A O Rapp