IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 1044 documents. Displaying 25 entries per page.


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Chemical Analysis of Southern Pine Pole Stubs Thirteen Months Following Treatment with Three Methylisothiocyanate Based Commercial Fumigants
2002 - IRG/WP 02-30294
Agricultural fumigants have been commercially used in the United States for over 20 years to control internal decay in utility poles and other wooden structures. Of the four fumigants which are currently used in the remedial treatment of utility poles, three are based on methylisothiocyanate (MITC) as being the principal fungitoxic component. Two of these MITC based fumigants, liquid metham sodi...
R J Ziobro, T C Anderson, D J Herdman, J Guzzetta, T Pope


A laboratory evaluation of tributyltin ethanesulphonate as an aqueous fungicide in wood preservation
1983 - IRG/WP 3229
Toxic limit data, using both leached and unleached wood test blocks, are reported for aqueous solutions of tributyltin ethanesulphonate against four Basidiomycete fungi, Poria placenta, Gloeophyllum trabeum, Coriolus versicolor and Coniophora puteana. An in situ study of the tributyltin compound in Scots pine and ponderosa pine sapwood has been carried out, using the technique of 119mSn Mössbauer...
R Hill, P J Smith, J N R Ruddick, K W Sweatman


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Experiences with supervision schemes for treated timber in Denmark
1984 - IRG/WP 3315
Since 1967 a voluntary supervision scheme for vacuum-pressure treatment was established in Denmark. In 1976 the Nordic Wood Preservation Council - NWPC - established a scheme based on wood preservation classes for treated timber as a joint technical standard valid in Denmark, Finland, Norway and Sweden. This paper deals with inspection results over 17 years for CCA treatment within our organizatio...
J Sabroe


Enzymatic study of Ceratocystis sp., blue-stain fungi on Pinus nigra
1999 - IRG/WP 99-10315
One of the main problems that the forest exploitation industry has with Pinus nigra wood is the blue-stain fungi, whose causing agent is unknown. Therefore, the objective of this work has been to study, through enzymatic tests of the isolated cultures, if these fungi infect Pinus nigra in any specific way. After the incubations, isolates of Ceratocystis were obtained. These were cultured in a sali...
M T De Troya, F Rubio, D Muñoz-Mingarro, F Llinares, C Rodríguez-Borrajo, M Yuste, M J Pozuelo, J I Fernández-Golfín


Detection of increased metal cations after wood decay using Chromeazurol-S
1997 - IRG/WP 97-20112
Chromeazurol-S (CAS) is a dye used for the spectrophotometric determination of metals, mainly aluminum (Al), berillium (Be) and copper (Cu). CAS has been widely used for determining the penetration of copper containing preservatives like CCA (AWPA A3-96). Additional uses include: i) detection of utility pole decay (Esyln, 1979), ii) a chemical spot test for aluminum in wood (Kukachka and Miller, 1...
F Green III, U Srinivasan, R B Miller


Field study: Wood degradation pattern in buildings and utility poles in tropical climates of Nigeria
1992 - IRG/WP 92-1521
The paper is the result of five years field study of wood degradation patterns in three ecological forest zones (Guinea Savannah, Tropical rain forest and mangrove forest zones, respectively). It involved 800 residential buildings and 700 electric overhead transmission poles. The methodology used was a modified Eslyn (6) test. A high rate of Ascomycetes and Basidiomycetes attack especially on the ...
E O Onuorah


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


Effect of test site location on in-ground preservative performance after 6 years
2001 - IRG/WP 01-20231
Pinus radiata test stakes were treated with 4.1 kg/m3 of CCA and Fagus sylvatica with 6.1 kg/m3 of CCA. Both wood species were also treated with a copper plus triazole preservative (3 kg/m3 of copper) and chlorothalonil plus chlorpyriphos in oil (4.8 kg/m3 chlorothalonil). Furthermore, P. radiata was treated with ammoniacal copper plus a quaternary ammonium compound (2.6 kg/m3 copper) and a 60/40 ...
R N Wakeling


IRG/COIPM INTERNATIONAL MARINE TEST - to determine the effect of timber substrate on the effectiveness of water-borne salt preservatives in sea-water. Progress Report 11: Report of fourth inspection (3 years) in Italy
1981 - IRG/WP 471
The wood samples of Alstonia scholaris, Fagus sylvatica, Pinus sylvestris were submerged in the sea at Follonica, Italy, in Apri1 1977. Follonica, latitude 42°55' North and longitude 10°45' East, is situated on the Tyrrhenian coast. The recorded temperature varies from 13°C td 25°C, salinity 37- 38%. and pH about 8. The inspections were carried out after 6 months (10/1977), 1...
A Gambetta, E Orlandi


A method test of chemicals for the treatment of walls infected with Serpula lacrymans
1992 - IRG/WP 92-2408
A method, which has been used in the UK for over 25 years, is described for assessing the effectiveness of products for application to walls during remedial treatment to eradicate the dry rot fungus Serpula lacrymans. Approvals for products previously used for this purpose in the UK are being changed. Approval for tri n-butyltin oxide has been withdrawn, and PCP derivatives can continue to be used...
J K Carey


Comparison of the anti-fungal efficacy of Cobra with drill perforation on oscillating pressure treated spruce transmission poles -Laboratory test
1988 - IRG/WP 3469
A laboratory method for measuring the depth of penetration of the fungicidal concentrations effective against basidiomycetes (brown rot) was developed. The tests on CCB oscillating pressure treated spruce transmission poles have shown that the depth of salt penetration can be increased by about 10 mm by a drill perforation before the impregnation. An even better penetration is reached, however, if...
E Graf, B Zgraggen


Methods for the assessment of wood preservative movement in soil
1995 - IRG/WP 95-50040-08
This paper presents preliminary results from a series of experiments constructed to provide laboratory data for the evaluation of the leaching of wood preservatives into and through soil. The experiments included: i) measurement of the adsorption of preservatives by soil; ii) determination of the concentration gradient of preservatives in soil following percolation of preservative solution through...
G E Holland, R J Orsler


Determination of corrosive effect of liquid wood preservatives to metals – First experiences with a National Standard which is in revision
2006 - IRG/WP 06-20321
The development of standards is an essential tool to characterise different kind of materials and products. An important aspect during the development of a new product is to check the corrosion behaviour with other materials. Corrosion can cause several problems like pitting corrosion. Consequently the knowledge concerning the corrosive effect of liquid wood preservatives is important due to the s...
E Melcher


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Working plan: Second international collaborative field trial
1995 - IRG/WP 95-20056
This paper describes the scope, objectives, and approaches to be used in the second international collaborative field trial approved by the Scientific Programme Committee for partial funding in 1994. The trial is designed to develop a broad data base on causal mechanisms, interactions, and factor affecting the performance of treated wood in ground contact. The trial encompasses 12 different field ...
H M Barnes, T L Amburgey


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


Leaching of copper-chrome-arsenic treated timber: Simulated rainfall testing
1996 - IRG/WP 96-50074
Six kiln dried radiata pine sapwood packs of timber were preservative treated with copper-chrome-arsenic preservative using a modified Bethell treatment schedule. The packs were then subjected to simulated rain leaching at specified periods after treatment. Higher chromium leachate was obtained when higher volumes of simulated rainfall were applied. Lower chromium leachate was obtained for timber ...
S Walley, P R S Cobham, P Vinden


Standard and accelerated testing of boron-additive wood protection systems
2005 - IRG/WP 05-30381
The main objective of this research was to determine the effectiveness of boron-additive protection systems for above ground applications by means of field testing. The two field test procedures used are based on the L-joint test described in the European standard EN 330. For the first set up the boron treated timber was coated in accordance with the standard EN 330 system. The second set up is ba...
A Mohareb, J Van Acker, M Stevens


IRG/COIPM INTERNATIONAL MARINE TEST - to determine the effect of timber substrate on the effectiveness of water-borne salt preservatives in sea-water. Progress Report 22: Report on the conditions of specimens at Sekondi, Ghana after 60 months
1986 - IRG/WP 4123
The results of the third inspection of CCA and CCB treated test panels exposed at Sekondi, Ghana in June 1980 are presented. None of the panels still in test, i.e. panels of Pinus sylvestris treated with CCA at 3 and 10%, Alstonia scholaris treated with CCA at 10%, Fagus sylvatica treated with CCA at 10%, and Erythrophleum ivorense and Mitragyna stipulosa both treated with CCB at 10%, shows any ex...
F F K Ampong, N Asare-Nyadu


Glue laminated poles - Progress report after 12 years' testing
1992 - IRG/WP 92-3685
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line just south of the Arctic circle in order to study their resistance against biological degradation. The tests have shown that the comparatively best performance will be obtained if each laminate is first treated wi...
J Jermer, Ö Bergman


Effects of the specimen position on fungal colonisation and wood decay by en 113 test fungi
1998 - IRG/WP 98-20136
For testing wood preservatives according to EN 113 it is common practice to plant the test blocks on neutral supports in order to prevent (1) a diffusion of chemicals into the agar medium and (2) an excessive moistening of the specimens. The procedure was employed in EN 350-1 for testing the natural durability of solid wood. It turned out to be of problematic nature because of the individual requ...
G Kleist, M-T Lenz, R-D Peek


Borates as wood preserving compounds: The status of research in the United States
1989 - IRG/WP 3542
This paper describes the extensive, on-going cooperative research effort among government and university research laboratories and industry to fully evaluate the potential for borates as wood preservatives in the United States. Research is discussed in terms of laboratory evaluations, field testing and mill trials, pilot plant pressure treatment studies, and remedial treatments. Future research pl...
H M Barnes, T L Amburgey, L H Williams, J J Morrell


Determination of fungitoxic value of preservatives in laboratory wood-block tests. Part 1: Standard procedures
1989 - IRG/WP 2326
By applying a modified agar-block method, a comparative analysis was made on the toxic value of the wood preservative CCA against the test fungus Serpula lacrymans. The procedure applied to determine the results accounted for different standards: EN (Toxic limit), ASTM (threshold retention), GOST (threshold retention and protection probability), PN (toxic doses) and JIS (value of efficiency). Desp...
J Wazny, J D Thornton


Previous Page | Next Page