Micronized Copper Wood Preservatives: Strong Indications of the Reservoir Effect
2013 - IRG/WP 13-30609
Micronized copper wood preservative systems were launched commercially in May 2006. Now, over 75% of the residential lumber produced in the USA is treated with micronized wood preservative formulations. Although considered controversial at first, the mode of action of micronized copper has been clearly defined by multiple authors over the years, as well as a need for a co-biocide in water-borne sy...
M H Freeman, C R McIntyre


Borate Redistribution in Glulam in an Above Ground Field Test
2014 - IRG/WP 14-30652
Researchers have refocused on the use of boratesin the wood protection industry in the last two decades due to their broad spectrum effectiveness against fungi and insects, and favourable environmental characteristics. This study was designed to determine borate distribution in a limited number of samples from a large field test of composites protected by a combination of coating and borate treatm...
P I Morris, A Temiz, J Ingram


Copper and chromium leaching from wood impregnated with chromium-copper containing preservatives: Results of different studies
2014 - IRG/WP 14-50300
Copper and chromium based wood preservatives remained one of the most important ingredients for wood protection solutions for protection of wood in demanding applications all-over the world. Leaching of heavy metals from treated wood is important from two different aspects; firstly from performance point of view, and secondly from environmental issues. However, the importance of these studies is i...
M Humar, N Thaler, E Melcher


Factors Affecting Performance of Preserved Wood Decking Against Decay Fungi
2015 - IRG/WP 15-30663
Decking is the largest market for residential preserved wood in the United States. Preserved decking must be resistant to colonization by decay fungi initiating from spores, and occasionally from mycelia due to elevated soil levels or adjacent untreated wood. The most vulnerable parts of a preserved wood deck are untreated, or under-treated, wood that becomes exposed by field cuts and checking. Fi...
R Stirling, P I Morris


The effect of preservative treatment on mechanical strength and structural integrity of wood
2015 - IRG/WP 15-30667
The use of wood for demanding construction applications is increasing in Europe. Wooden constructions are frequently designed of susceptible conifer wood, which is endangered by wood decay fungi in wet applications. Therefore in many cases treating wood with preservatives is unavoidable to ensure the desired service life. However, chemical treatment of wood can result in changes of its mechanical ...
M Humar, D Kržišnik, C Brischke


Recycling of used railroad ties via two-staged pyrolysis for fractionation of wood preservatives and bio-oil: pyrolytic characterization by TGA and Py-GC/MS
2015 - IRG/WP 15-50311
Creosote and copper naphthenate (CuNap) (in an oil carrier) treated railroad tie materials (crossties or sleepers) were initially heat-treated at 200 – 300 oC and subsequently pyrolyzed via thermogravimetric analysis (TGA) and pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) to recover wood preservatives and produce a higher quality bio-oil. Preservative-desorptive temperatures at 200 a...
Pyoungchung Kim, J Lloyd, Jae-Woo Kim, N Labbe


Performance of copper treated poles and posts after three to fifteen years of exposure
2016 - IRG/WP 16-20595
Copper based wood preservatives are one of the most important wood preservatives for heavy-duty applications. Wood treated with copper-based preservatives performs excellent if applied according to preservative specifications. If used improperly premature failures might appear. In order to elucidate properties of copper treated wood in use, utility poles and posts treated with copper-based preserv...
M Humar, N Thaler


Moisture monitoring in WW2 partisan hospital Franja
2016 - IRG/WP 16-20596
Material climate of wood used for construction of WW2 Partisan hospital Franja was monitored for approximately one year. Partisan hospital is located in the bottom of tiny gorge Pasice in Slovenia. Hence, wood moisture content on eight respective location and wood temperature was determined twice per day with Scanntronik equipment Gigamodul and Thermofox. The results clearly showed that despite of...
M Humar, N Thaler, B Lesar, A Žagar


Overview of the treated wood quality control program in the United States with the recent challenges and advances
2017 - IRG/WP 17-20616
In the past two decades, there have been significant and rapid changes in wood protection technologies for residential applications which have moved away from long established heavy duty metal oxide based products such as chromated copper arsenate (CCA). The successor generation of wood protection systems usually contain copper as the primary biocide, in combination with carbon-based co-biocides s...
L Jin


Uncertainty in life cycle assessment of preservative treated wood – copper and freshwater ecotoxicity
2017 - IRG/WP 17-50331
Life cycle assessment (LCA) is a method for quantifying the environmental impacts of a product over the life cycle. In the last years, there have been a growing application of LCA in developments of environmental product declaration (EPD), which is utilised by professional procurement of materials for buildings. For legislative issues, LCA have also been used to assess application of creosote to t...
L G F Tellnes


Influence of different triazoles as co-biocides in wood preservatives on efficacy and the environmental impact
2018 - IRG/WP 18-50333
In this study we investigated the efficacy and impact on the environment of different co-biocide triazoles in wood preservatives. Four different formulations (all containing 9.5% Copper) contained individual and combinations of cyproconazole, tebuconazole, propiconazole as co-biocides. Four formulations were tested according to EN 113 and EN 84 (ageing) to determine the brv for each formulation. T...
M Klamer, T Jensen, S Bang-Achton, E Morsing


Treatability of South African-grown Eucalyptus grandis with water-borne copper azole and disodium octaborate tetrahydrate wood preservatives
2021 - IRG/WP 21-40920
This study investigated the treatability of the sapwood and heartwood of sawn Eucalyptus grandis with copper-azole (CuAz) and disodium octaborate tetrahydrate (DOT) water-borne preservatives towards improving its durability for enhanced use in structural solid wood applications. The results obtained showed that, at a moisture content of 12 ± 1%, sawn E. grandis sapwood can be impregnated to a mea...
A A Alade, Z Naghizadeh, C B Wessels


Evaluation of Decay Resistance of Copper-based Preservatives Treated-Wood exposed to different field test sites in Korea
2022 - IRG/WP 22-20679
In Korea, preservative treated wood is required to have a stamp on the surface which contains information such as wood species, use categories, and the company that treated the wood. Such stamping is necessary to safely and appropriately use the treated wood. Since majority of treated wood is being used outdoor environment, the treated wood must have efficacy against wood decay fungi or termite. I...
W-J Hwang, S-M Yoon, Y Park, Y-S Choi, H-M Lee, J-W Kim


Establishing the minimum effective penetration of wood preservatives in the refractory heartwood of E. nitens
2023 - IRG/WP 23-30780
Conventional pressure treatment of many Australian hardwoods results in little to no penetration of heartwood and a non-uniform envelope treatment of <5 mm surrounding a mostly untreated core. This is a major issue for many of the low durability plantation hardwood timbers that are grown in Tasmania, which contain high percentages of heartwood. Long term studies on softwoods such as spruce decking...
J R Vargas, J J Morrell, L Yermán, K C Wood


X-ray micro-computed tomography of copper distribution in CA, ACQ and MCA treated wood and changes in microstructure of ACQ-treated southern pine following natural weathering
2024 - IRG/WP 24-20707
We hypothesized that X-ray micro-CT would be able to visualize: (a) the distribution of copper in CA-treated southern pine; and (b) microstructural changes in ACQ-treated southern pine exposed to natural weathering. Small blocks were removed from southern pine samples treated with CA and also southern pine treated with ACQ and MCA. Small blocks were also removed from ACQ-treated boards (flat and p...
D Feng, M Turner, P D Evans


Comparison of copper leaching from alkaline copper quat and copper compound nanosol-based wood preservative treated wood
2024 - IRG/WP 24-20726
To improve the leaching resistance of copper ion-based wood preservatives, copper compound nanosol-based wood preservatives were developed and its copper leaching characteristics were evaluated. Three types of preservatives (DC1, DC2, DC3) were prepared with different crystallinity and dispersant types of copper compound nanosol, and the copper concentration was adjusted to be the same as that of ...
Y-S Choi, S-M Yoon, J O Kim, J-G Kang, J-G Park


Copper migration from preservative-treated Douglas-fir decking: models vs laboratory leaching data
2024 - IRG/WP 24-50390
The ability of a model to predict copper migration from Douglas-fir treated with organic metallic substances into a freshwater slough was evaluated against data generated through simulated overhead leaching. The model predicted very high loadings of ammoniacal copper zinc arsenate, alkaline copper quaternary or copper azole that had the potential to impact water quality while data from the exper...
M J Konkler, G Presley, J J Morrell, T Singh


Quantitative assessment of wood preservative emissions to waterways
2024 - IRG/WP 24-50393
The Organisation for Economic Co-operation and Development (OECD) Emission Scenario Document (ESD) for Wood Preservatives provides methods to quantify the release of active substances from treated wood for various scenarios including sheet pilings in a flowing waterway (OECD 2013). The ESD is used for environmental risk assessment of wood preservatives according to the Biocidal Products Regulation...
K J Rader, R Carbonaro, C Mackie


Danish wood preservatives approval system with special focus on assessment of the environmental risks associated with industrial wood preservatives
2001 - IRG/WP 01-50166-01
The following is a description of the procedure used by the Danish Environmental Protection Agency to assess the environmental risks associated with preservatives used in the pressure impregnation of wood. The risk assessment covers issues considered to be of significance for the environment and which are adequately documented so as to allow an assessment. Such issues are persistence and mobility ...
J Larsen


Finishes for outdoor timbers
1975 - IRG/WP 378
Anonymous


Management of the wood and additives wastes in the wood processing industries: Problematics and technical answers review
1996 - IRG/WP 96-50073
Management pathways for pure wood subproducts are well known and used; but as soon as additives like preservatives, glues, varnishes or coatings are present within the wood wastes, their disposal or valorization becomes more tricky. The different kinds of mixed wood wastes of the wood processing industries, from the sawmill to the furniture manufacture, are identified herewith and their diversity ...
S Mouras, G Labat, G Deroubaix


Proposed method for out-of-ground contact trials of exterior joinery protection systems
1981 - IRG/WP 2157
Methods for testing the efficacy of preservative treatments for exterior joinery are described using the format of a European Standard. Commercially used treatments applied to jointed test units (L-joints) which are then protected by conventional finishes are exposed to normal outdoor hazards out of ground contact. Assessment is made a) by determining eventual failure through decay and b) by destr...
J K Carey, D F Purslow, J G Savory


JWPA method for testing effectiveness of surface coatings with preservatives against decay fungi
1981 - IRG/WP 2164
In 1979 JWPA established a new method for testing effectiveness of surface coatings in accordance with practical use of preservative-treated lumber. Comparing the new testing method with JIS A 9302, a few new trials - size of wood specimen, weathering procedure, and decay-test procedure - are incorporated....
K Tsunoda


Wood preservation in Poland
2004 - IRG/WP 04-30362
Dynamic growth of market demand for wooden elements and articles, generated in Poland increase of interest in industrial preservation. Today, Poland is a substantial producer and exporter of wood made products. Majority of exported wood - approximately 70% - is scotch pine (Pinus silvestris L.), which, due to its natural durability, requires preservation....
A Kundzewicz


Wood preservatives: Field tests out of ground contact. Brief survey of principles and methodology
1976 - IRG/WP 269
This paper contains the following spots: 1.: The general need for field tests. 2.: Interests and limits of field tests in ground contact. 3.: Various methods in use for out-of-ground contact field tests. 4.: Fungal cellar tests are they an alternative to above-ground decay exposure tests? 5.: Conclusions....
M Fougerousse