IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 174 documents. Displaying 25 entries per page.


Evaluation of a laboratory soft rot test on basis of weight loss and residual strength
1989 - IRG/WP 2336
Based on the principles of different previously reported experimental procedures dealing with laboratory soft rot testing, a study was conducted on treated poplar and beech. Preservatives used were CCA, CCF, AAC, Azaconazole and TCMTB. Treated samples were exposed for three months in a vermiculite substrate to Chaetomium globosum. Evaluation was based on absolute mass loss, percentage weight loss ...
W Verbeke, J Van Acker, M Stevens


The potential use of impregnated coconut wood for power line poles in rural areas of Java
1980 - IRG/WP 3130
Electrification of rural areas in Java needs thousands of power line poles which are relatively cheap in price, but have adequate strength and are fairly durable. A choice of wood species is available in the country. One alternative is coconut wood found in abundance in the villages. This may give a solution to Java's needs since supplies are readily available almost everywhere. Based on ...
H Yudodibroto


The degradation of wood surfaces by dilute acids
1985 - IRG/WP 3326
Thin radial/longitudinal sections(~100 µ) of Corsican Pine (Pinus nigra) and Lime (Tilia vulgaris), were exposed to Sulphuric, Sulphurous, nitric, acetic, and formic acid at 40°C in the pH range 2-6. After about 3 months exposure to Sulphuric, nitric, acetic and formic acid at pH 2.0 Pine lost some 20-25% of its tensile strength. Losses in tensile strength due to sulphurous acid were greater bei...
P D Evans, W B Banks


Determination of toxicity data for preservatives against Basidiomycetes by measuring the reduction in compression strength of wood
1988 - IRG/WP 2297
Blocks of Pinus radiata D. Don were treated to 12 retention levels with CCA and NaPCP. These were exposed for 12 weeks in agar jars to the dry rot (brown rot) Serpula lacrymans (Schum. ex Fr.) S.F. Gray. After mass loss determination, the same blocks were tested for reduction in compression strength parallel to the grain. Using both these parameters, together with interpolated 6 week strength loss...
J Wazny, J D Thornton


Glue-line additives for protecting plywood. A review
1978 - IRG/WP 2102
The conclusions of this review are: 1) Insecticidal glue-line additives can be used satisfactorily to protect plywood against insect attack. 2) It is uncertain, in spite of some claims, wether fungicidal glue-line additives can be similarly used to protect plywood against fungi under damp conditiones. There is a need for further work to validate the mycological tests that may be used to investigat...
R Cockcroft


The effect of oil-borne preservative treatments on the shear strength of FRP/wood composite adhesive bonds
2003 - IRG/WP 03-40265
Reinforcement of structural wood components with Fiber Reinforced Polymer (FRP) will enhance the beam’s strength, but actual data on long-term durability is sparse, not well documented or not readily accessible. In this study, bond properties of FRP-wood composite materials were investigated following treatment with creosote or copper naphthenate preservatives. The properties investigated inclu...
B Herzog, B Goodell, R Lopez-Anido


Supply of wooden transmission and telephone poles in Tanzania: Problems and possible solutions
1987 - IRG/WP 3424
The eucalypts which have been used widely for utility poles for more than 30 years have dwindled remarkably from traditional supply areas. Consequently, pole-using authorities are considering importing poles from abroad. This alternative is considered unrealistic and costly. The aims of this paper are: - to dispel fears of pole scarcity and to show that an abundant resource of a variety of tree sp...
K K Murira, S A Diwani


A non-destructive testing technique for wood poles
1987 - IRG/WP 2293
A method has been developed to evaluate the stiffness and condition of a wood pole based on structural dynamics. This paper describes the results of tests performed on nearly 200 wood utility poles across Western Canada. A high correlation exists between the dynamic non-destructive test and direct mechanical tests. The need for an accurate non-destructive testing technique is demonstrated by the f...
W M Murphy, D E Franklin, R A Palylyk


Wood cement composites using spent CCA treated wood
1999 - IRG/WP 99-50126
The feasibility of using spent or out-of-service CCA treated wood as a component of wood/cement composites was evaluated. Cold pressed wood particle cement boards were made using CCA treated particles from a red pine (Pinus resinosa Ait.) pole removed from service and from untreated red pine wood from a new pole. Boards were manufactured using a range of wood to cement ratios and water to cement r...
Chen Huang, P A Cooper


Decay rates and strength and stiffness loss in foundation beams
1992 - IRG/WP 92-1563
The TNO Centre for Timber Research has executed an extensive research programme into the rate of decay in foundation beams, as a result of lowering of ground water tables. The aim of the research was to develop a method, predicting the decrease in strength and stiffness in beams, due to wood decay during drytime of foundation beams. With the calculated extremes in decay, the damage caused by local...
P Esser, H S Buitenkamp


A comparison analysis of eight strains of Serpula lacrymans (Schum. ex Fr.) S.F. Gray
1991 - IRG/WP 2362
Investigations were previously carried out to compare eight strains of Serpula lacrymans (Schum. ex Fr.) S.F. Gray (some used in various countries as standard test strains): FPRL 12C (England), FPRL 12E (Germany), Warsaw III (Poland), HFP 7802 (Japan), DFP 16508, 16509, 16521 and 16522 (Australia). Studies included growth rate and dry mass of mycelium, decay capacity, reduction of compression stre...
J Wazny, J D Thornton


A questionnaire survey to establish the perceptions of UK specifiers concerning the key material attributes of timer for use in marine and fresh water engineering
2004 - IRG/WP 04-10519
Engineers have a key role in making informed decisions on the type of materials to be used in the schemes they design and construct. Currently, in England and Wales, it is believed that some £500m per year is invested in flood and coastal defence engineering. There is a lack of centralised data in the UK holding information on timber for usage in fluvial and, particularly coastal engineering. A...
J R Williams, G S Sawyer, S M Cragg, J Simm


High-energy multiple impact (HEMI)-test – Part 2: A mechanical test for the detection of fungal decay
2006 - IRG/WP 06-20339
The suitability of the high-energy multiple impact (HEMI)-test for detection of early fungal decay was examined. The HEMI – test characterizes the treatment quality of thermally modified wood by stressing the treated material by thousands of impacts of pounding steel balls. This method differentiates between heat treatment intensities, which are expressed by structural changes of the wood. Simil...
C R Welzbacher, C Brischke, A O Rapp


Performance of Preservative Treated Parallel Strand Lumber in Marine Exposures.
2006 - IRG/WP 06-30407
The performance ACZA treated Douglas-fir and CCA southern pine parallel strand lumber (PSL) was studied in marine exposures in Florida or Oregon. While materials treated to retentions below the recommended levels for marine exposure were attacked in Oregon, properly treated panels of either species performed well. Panels treated with these same chemicals and exposed in Florida experienced attack ...
J J Morrell, C S Love, P Merrick


High-energy multiple impact (HEMI)-test – Part 1: A new tool for quality control of thermally modified timber
2006 - IRG/WP 06-20346
Thermal modification processes improve durability and dimensional stability of wood, but the strength properties, especially the dynamic ones, are compromised and need to be considered with respect to industrial quality control. Results from standard dynamic strength testing, such as impact bending tests, suffer from high variability, and therefore require a high number of replicates. To overcome ...
C Brischke, A O Rapp, C R Welzbacher


Exposure of CCA and ACZA treated parallel strand lumber to marine borer attack in northeastern and southeastern waters of the United States of America
2006 - IRG/WP 06-30400
Southern pine and Douglas fir Parallel Strand Lumber (PSL) panels were treated with chromated copper arsenate (CCA) or ammoniacal copper zinc arsenate (ACZA), respectively and exposed in a marine environment in Massachusetts (northeastern USA coast) for 7 years. Similarly treated panels were also exposed to a site on the Atlantic coast Florida (southeastern USA) for the same period. In the northe...
B Goodell, P Merrick, J Jellison, Y Qian


Characteristics of treated oriented strand lumber using recycle chips
2006 - IRG/WP 06-40343
The Kyoto Protocol for preventing global warming has come into effect, and the Cabinet Council was decided on the amount of carbon dioxide exhaust to be reduced in Japan. Moreover, the recycling of demolition waste wood is mandated under the “Construction Material Recycling Law” as one of the mechanisms for Japan to form the recycling society. The law encourages the utilization of demolition w...
T Shibusawa, A Miyatake, K Yamamoto, K Hashimoto, H Sonobe


Influence of Grain Direction on Penetration, Retention, and Leaching of CCA(C) in Sapwood and Heartwood of Kenyan-Grown Eucalyptus saligna and Acacia mearnsii
2007 - IRG/WP 07-40383
Penetration, retention, and leaching of CCA (C) in relation to grain orientation were tested in small (50mm x 50mm x 200mm) sapwood and heartwood samples of Eucalyptus saligna and Acacia mearnsii. In both sapwood and heartwood of the two species, the results showed a consistent pattern: Transverse > Radial > Tangential. Whereas penetration, retention, and leaching were significantly high i...
R Venkatasamy


Influence of Grain Direction on Penetration, Retention, and Leaching of CCA(C) in Sapwood and Heartwood of Kenyan-Grown Cupressus lusitanica and Pinus patula
2007 - IRG/WP 07-40384
The influence of grain orientation on penetration, retention, and leaching of CCA (C) was tested on small samples of sapwood and heartwood of Cupressus lusitanica and Pinus patula. Samples measuring 50mm x 50mm, and 200mm in the longitudinal axis were sealed to expose only transverse, or radial, or tangential faces, pressure treated with 6% CCA (C), and penetration, retention and leaching of the ...
R Venkatasamy


The effect of an ionic liquid of imidazolium tetrafluoroborates series on Scots pine wood properties
2007 - IRG/WP 07-40357
Ionic liquids (ILs) of imidazolium tetrafluoroborates series penetrate Scots pine wood very well and are active against wood destroying fungi. The requirement to use ILs as wood preservatives is determined by the liquid influence on the functional properties of wood. Investigations were undertaken to clarify the influence of an ionic liquid, 3-heptyloxymethyl-1-methylimidazolium tetrafluoroborate ...
A Fojutowski, R Szukala, J Pernak


Effects of sodium hypochlorite on compression strength and copper retention of spruce wood treated with copper azole and alkaline copper quat
2007 - IRG/WP 07-40362
This work investigates the effects of sodium hypochlorite on compression strength values and copper retention ratios of refractory spruce wood (Picea oriental L.) treated with the waterborne preservative Copper Azole, (CBA-A, Tanalith-E 3492) and alkaline copper quat (ACQ-2200). Before the copper azole and alkaline copper quat treatment, the samples were immersed in 500 ml of sodium hypochlorite s...
S Yildiz, E Dizman, A Temiz, Ü C Yildiz


Fire Safety of Wood Floor Assembly: Model and Full-scale Test
2007 - IRG/WP 07-20375
The present paper describes the model for the prediction of fire safety of wood floor assemblies. The model includes heat transfer model for the calculation of the flow of heat in floor assembly and structural model for the analysis of the mechanical performance of wood joists. The floor assemblies considered in this paper are constructed with nominal 2x10 (38x241mm) wood joists lined by Type X ...
H Takeda


Anatomical, physical and chemical changes of Bamboo (Phyllostachys puberscence ) during weathering processes
2008 - IRG/WP 08-10650
Bamboo (Phyllostachys puberscence) culms with 1, 2, 3 year old were exposed to natural weathering condition in Gwangju, Korea for 12 months. Changes in color, surface topography, strength and chemical properties were investigated using various microscopic and instrumental techniques. After one year’s weathering, the color of bamboo became lighter but strengths of bamboo did not change significan...
Jong Sik Kim, Kwang Ho Lee, Mi Young Cha, Yoon Soo Kim


Evaluation and identification of extractives from Iranian walnut (Juglans regia L.) by GC/MS technique for protection of non-decay resistant species
2008 - IRG/WP 08-10670
The use of walnut extractives is interest as environment friendly wood preservatives in the wood preservation industry. In this study, organic solvents were used to remove extractives from Iranian walnut heartwood samples. The solvent was removed by rotoevaporation, and Identification of chemical compounds in the Walnut extractives was done by using GC/MS technique. The toxicity of various extract...
S K H Hashemi, D Parsapajouh, H Khademi Eslam


Mechanical strength of wood from the Vasa shipwreck
2008 - IRG/WP 08-20381
Samples from three ancient ship wrecks (Vasa, Elefanten, and Gröne Jägaren) and recent oak samples as reference were examined with regard to mechanical strength using the high-energy multiple impact (HEMI) - test method, which delivers the resistance to impact milling (RIM) of a material. Adoption and optimisation of the test method for the particular sample size of the wooden drilling cores was...
A O Rapp, C Brischke, C R Welzbacher, T Nilsson, C Björdal


Previous Page | Next Page