Chemical and biological investigations of double-vacuum treated windows after 5 years in service
1983 - IRG/WP 3219
In 1980 The Swedish Wood Preservation Institute initiated an investigation to study the degradation of TBTO and possible fungal attack in double-vacuum treated window joinery in service during 5 years. A hospital in Gothenburg was chosen that was built during 1969 to 1976. Both untreated and double-vacuum treated windows of Pinus sylvestris were used. A brown alkyl oil type paint (Nordsjö system ...
J Jermer, M-L Edlund, B Henningsson, W Hintze, S V Ohlsson


Effect of Pseudomonas cepacia on the activity of a mixture of wood staining fungi on ponderosa pine sapwood
1995 - IRG/WP 95-10107
There are major incentives for limiting the degree of fungal discoloration which occurs during wood processing. Most lumber producers apply prophylactic fungicides which limit microbial growth, but increasing restrictions on the use of these chemicals have encouraged the search for alternative stain prevention strategies. Among the possible strategies for stain prevention is biological control. Wh...
J J Morrell, R K Velicheti


Biological and physical properties of phenolic-resin treated wood before and after natural weathering
1999 - IRG/WP 99-40132
Biological and physical properties of phenolic resin-treated particleboards, which were made from fast growing tress and agrowaste as raw materials, were evaluated before and after natural weathering in tropical climate. The particles were sprayed with a mixture of a low molecular weight phenol-formaldehyde resin (5.0, 7.5 and 10% loading) and the adhesive phenol resin (8% loading). Results with l...
S Yusuf, Y Sudiyani, H Kajita, Y Imamura, M Takahashi


Comments on leaching in view of accelerated testing
1977 - IRG/WP 294
We developed an accelerated test for leaching at elevated temperatures (75-85°C). This test was used for the examination of 11 preservative formulations containing Cu, Zn and As. The data obtained from these experiments were compared with data on some formulations tested by ASTM standard leaching test. The method consists in making a large surface to volume ratio of wood from a treated block by c...
J Rak


Effect of post-treatment drying schedule on the modulus of elasticity of CCA-treated southern pine dimension stock using nondestructive methods
1987 - IRG/WP 3413
This paper describes the results from the nondestructive testing for modulus of elasticity (MOE) of southern pine (Pinus sp.) 2 x 6's treated with chromated copper arsenate and redried using three commercial kiln schedules. The data indicate that redrying CCA-treated southern pine dimension stock treated to above-ground retentions (4 kg/m³) has no deleterious effect on the MOE, regardles...
H M Barnes, S Moore


Determination of corrosive effect of liquid wood preservatives to metals – First experiences with a National Standard which is in revision
2006 - IRG/WP 06-20321
The development of standards is an essential tool to characterise different kind of materials and products. An important aspect during the development of a new product is to check the corrosion behaviour with other materials. Corrosion can cause several problems like pitting corrosion. Consequently the knowledge concerning the corrosive effect of liquid wood preservatives is important due to the s...
E Melcher


Untersuchungen zur Prüfung mit Moderfäulepilzen im Vermiculit-Eingrabe-Verfahren
1972 - IRG/WP 214
Im Hinblick auf die Entwicklung eines Prüfverfahrens für die Bestimmung der moderfäulewidrigen Wirksamkeit von Holzschutzmitteln wurden Versuche mit Reinzuchten von Pilzen und mit Vermiculit als Trägersubstanz sowohl mit unbehandelten als auch mit Schutzmittelgetränkten Holzproben durchgeführt. Dabei wurde die Eignung von handelsüblichen, eintachen Einweg-Kunststoffbechern anstelle der bish...
W Kerner-Gang, M Gersonde


Collaborative soft rot tests: Final Report
1978 - IRG/WP 2106
Since preparation of Document No: IRG/WP/258 results have been received from the remaining collaborators. Thus there is a little further to add to the conclusions already derived, those in Document No: IRG/WP/251 being as follows: 1) the exposure system used sometimes resulted in excessive weight gains in the sterile check blocks. Consequently the corrected loss in weight of the test blocks could ...
J G Savory, J K Carey


Imaging fungal deterioration of wood using x-ray microtomography
1997 - IRG/WP 97-10240
Nondestructive tomographic images of solid Southern yellow pine (SYP) wood and SYP during deterioration by wood decay fungi were obtained by using a new class of synchrotron X-ray computed microtomography (CMT). The CMT images will provide information about spatial relationship between degrading fungi and wood structures. Wood samples were scanned with synchrotron-generated X-rays at high resoluti...
B Illman, B A Dowd


Leaching of copper-chrome-arsenic treated timber: Simulated rainfall testing
1996 - IRG/WP 96-50074
Six kiln dried radiata pine sapwood packs of timber were preservative treated with copper-chrome-arsenic preservative using a modified Bethell treatment schedule. The packs were then subjected to simulated rain leaching at specified periods after treatment. Higher chromium leachate was obtained when higher volumes of simulated rainfall were applied. Lower chromium leachate was obtained for timber ...
S Walley, P R S Cobham, P Vinden


Effects of chemical pretreatment of Douglas-fir heartwood on efficacy of potential bioprotection agents
1990 - IRG/WP 1440
Biological protection against wood decay fungi represents an environmentally attractive alternative to the use of chemicals; however, the process of identifying suitable candidates and the conditions that ensure successful protection pose major challenges. One critical aspect of this problem is to identify organisms that can rapidly and uniformly colonize the wood. Wood contains low levels of nutr...
B Dawson-Andoh, J J Morrell


Standard and accelerated testing of boron-additive wood protection systems
2005 - IRG/WP 05-30381
The main objective of this research was to determine the effectiveness of boron-additive protection systems for above ground applications by means of field testing. The two field test procedures used are based on the L-joint test described in the European standard EN 330. For the first set up the boron treated timber was coated in accordance with the standard EN 330 system. The second set up is ba...
A Mohareb, J Van Acker, M Stevens


Some fundamental thoughts on the prediction of field performance from lab-testing based on comparison of lab and field test results of some copper-free materials
2003 - IRG/WP 03-20269
In the paper results from lab testing (ENV 807 and EN 113) are compared with field results (EN 252) of differently treated wood. Depending on the type of the organic biocide containing material and depending on type of soil and type of decay differences were found in suitability of the lab methods to predict field performance. The attempt is made to interpret the found differences. Furthermore it ...
A O Rapp, U Augusta


Evaluation of the protective means of some wood preservatives by means of accelerated tests
1973 - IRG/WP 232
In site conditions of the eastern site in the forest-steppe part of the Krasnovarsk region, the relative effectiveness of a series of wood preservatives was obtained by means of field tests. To obtain a more accurate evaluation of the protective qualities of these accelerated tests were carried out in laboratory conditions. In 9 boxes filled with non-sterile soil taken from the site, 72 samples of...
I A Petrenko


Determination of fungitoxic value of preservatives in laboratory wood-block tests. Part 2: Statistical estimation
1989 - IRG/WP 2327
Laboratory modified agar-block tests were made to determine the fungitoxic value of the wood preservative CCA against the test fungus Serpula lacrymans using statistical methods. With the aid of statistical computer programmes based on the least square method. the regression equation was found for the dependence between sample mass loss and preservative retention both in terms of percentage and fo...
J Wazny, J D Thornton, K J Krajewski


Nondestructive assessment of biodegradation in southern pine sapwood exposed to attack by natural populations of decay fungi and subterranean termites
1994 - IRG/WP 94-20042
Field methods for evaluating decay resistance of experimentally treated materials lack a means for quantitative measurement of residual strength. Quantitative relationships between speed of impact-induced waves travelling parallel to the grain and residual compressive strength have been demonstrated in softwood attacked by brown rot-decay fungi, but the effects of termites have not been documented...
R C De Groot, R J Ross, W Nelson


Biological resistance of electrolessly plated wood (1). Preliminary report
1994 - IRG/WP 94-40024
Surface metal coating is considered to improve biological resistance of wood as some metal ions are fungitoxic. Six wood species (three softwoods: Cryptomeria japonica, Tsuga heterophylla and Larix spp; three hardwoods: Fagus crenata, Acer mono and Betula platyphylla) were electrolessly plated with nickel or copper, and those were served for laboratory evaluation of their resistance against decay ...
M Hasegawa, K Tsunoda, T Yoshimura


Glued laminated poles - Progress report after 18 years' testing
1998 - IRG/WP 98-20140
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line in Vuollerim in northern Sweden in order to study their resistance against biological degradation. The tests have shown that the best performance will be obtained if each laminate is first treated with a water-bo...
Ö Bergman, J Jermer


The effect of soil pre-exposure on the results of laboratory Basidiomycete testing
1991 - IRG/WP 2385
Scots pine sapwood blocks were treated with several concentrations of copper chrome arsenic (CCA), copper chrome boron (CCB) and a copper modified quaternary ammonium compound (CMAAC). Leached and unleached samples were exposed in a basidiomycete monoculture test using Coniophora puteana, a copper tolerant brown rot. Prior to testing half of the blocks were buried in unsterile soil for 4 weeks. Th...
S M Gray


The density factor in termite bioassays
1985 - IRG/WP 1252
The initial and final floor surface and food block surface actually used by termites in a small container were converted to estimates of "Living Space" and "Feeding Space" densities for 1/32 to 1½ g groups of termites. The termites were provided with blocks of blotter paper as a food supply. Except where 1½ g groups exhausted the food, the survival of termites was uniformly high (averaging >9...
G R Esenther


Biological and chemical investigations for the assessment of the environmental impact of wood preservative components
1999 - IRG/WP 99-50127
This study was carried out in order to investigate the suitability of biological and chemical techniques to evaluate the environmental impact of wood preservatives depleted from impregnated wood. Small specimens (15*25*50 mm3) of Scots pine sapwood (Pinus sylvestris) were treated with a CCB salt. After fixation the treated and untreated samples were washed-out according EN 84, and the different le...
E Melcher, H-W Wegen


Glue laminated poles - Progress report after 12 years' testing
1992 - IRG/WP 92-3685
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line just south of the Arctic circle in order to study their resistance against biological degradation. The tests have shown that the comparatively best performance will be obtained if each laminate is first treated wi...
J Jermer, Ö Bergman


Biological resistances of wood-metaborate composites using the borax solution system
2001 - IRG/WP 01-30259
Combinations of wood and metaborate composite were prepared from sapwood specimens of Japanese cedar (Cryptomeria japonica) and the borax and metallic salts system using the diffusion-penetrated process. Wood-metaborate composites were produced as follows: water-saturated specimens were first impregnated by a saturated borax solution and then diffuse-penetrated with Zn2+, Ca2+, or Pb2+ solution. B...
Liang Lin, T Furuno


A new concept for the evaluation of wood durability for out of ground contact using accelerated L-joint testing
1997 - IRG/WP 97-20123
Since the wood preservation sector is developing in favour of defining exactly the utilization of wood products and preservation techniques as a function of the envisaged hazard class, more in particular the hazard classes 3 and 4 (EN 350) there is obviously a need for a test method evaluating natural durability for out of ground contact applications. Based on the L-joint test as described in the ...
J Van Acker, M Stevens


Antagonistic properties of Gliocladium virens against wood attacking fungi
1996 - IRG/WP 96-10162
Gliocladium virens has shown good antagonism against decay fungi in agar medium and in wood blocks. Gliotoxin produced by Gliocladium virens is associated with biocontrol of some plant diseases, but its importance to biocontrol of wood-attacking fungi is unknown. We investigated the ability of gliotoxin-producing (GLT+) isolates of Gliocladium virens and gliotoxin-deficient (GLT-) mutants of Glioc...
T L Highley, H S Ananthapadmanabha, C R Howell