Testing of alkylammonium compounds
1981 - IRG/WP 2152
Following laboratory soil block tests which showed that Bardac 20 possessed a fungicidal threshold similar to that of chromated copper arsenate, treated ponderosa pine sapwood stakes were installed in a field test site near Vancouver, Canada. Two years after installation all the stakes show signs of fungal degradation. Seven stakes have been removed from the test due to total loss of strength afte...
J N R Ruddick


Laboratory investigations about the mobility of some inorganic wood preservatives in soils
1998 - IRG/WP 98-50101-22
Wood preservatives and components of wood preservatives leached from impregnated wood can enter the soil and thus contribute to the pollution of the groundwater. However, there is lack of understanding concerning the interacting parameters of wood preservative, leachate, soil and soil solution. To characterise of the behaviour of active ingredients and for the assessment of their environmental imp...
E Melcher, R-D Peek


Leaching of Active Components from Preservative Treated Timber. Stage 1: Semi-Field Testing
2004 - IRG/WP 04-20302
The project is aiming at finding realistic leaching rates from preservative-treated wood in use class 3 (above ground). The project focuses on developing a field trial method for investigating leaching. Panels are subjected to outdoor exposure under natural weather conditions at a test field at the Danish Technological Institute. The leachate is collected and monitored by chemical analysis of the...
N Morsing, B Lindegaard


The effect of sapwood on the rate of deterioration of fence posts
1986 - IRG/WP 1277
In order to evaluate the effect of the presence of sapwood on the rate of deterioration of fence posts, 30 specimens with and without sapwood of Eucalyptus citriodora, Eucalyptus paniculata, Eucalyptus saligna and Eucalyptus tereticornis were exposed in three test sites in the State of São Paulo, Brazil. The results of the inspection carried out in 1985, after 5 years of exposure, are reported in...
M S Cavalcante, G A C Lopez, E S F Mucci, R G Montagna


Collaborative field experiment: Analysis of copper and chromium in stakes of the four reference timbers
1982 - IRG/WP 3213
The stakes analysed belong to the Swedish set of the four reference timbers of the collaborative field experiment (Document No: IRG/WP/367). Before the field exposure 60 mm were cut off the end of each stake. This was done in order to be able to carry out chemical analyses as well as different types of testing. Some of the material has been used in softrot tests (Document No: IRG/WP/1151)....
T Nilsson


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Austrian field test method for anti-sapstain chemicals
1994 - IRG/WP 94-20020
Although Austria is a small country, the annual consumption of anti-sapstain products ranks to approximately 500 tons annually. In 1994, only three products will be approved by the Austrian Wood Preservation Committee (AWPEC). There is demand for a field test method, which demonstrates the efficacy of an anti-sapstain product and consequently implies the acceptance and approval of product by the A...
R Gründlinger, M Brandstätter, H Melzer, O Janotta


Exterior weathering trials on radiata pine roofing shingles
1985 - IRG/WP 3240
A series of test roofs clad with radiata pine (Pinus radiata D. Don) shingles that had been pressure-treated with various water-borne preservative formulations were installed at a Forest Research Institute test site in Rotorua in 1977. A further series of test roofs installed in 1978 included radiata pine shingles pressure-treated with a commercial light organic solvent preservative (LOSP). Evalua...
D V Plackett, C M Chittenden, A F Preston


Comparative performance of pentachlorophenol and copper naphthenate in a long term field stake test
2000 - IRG/WP 00-30243
In this study the performance of copper naphthenate (Cu-Nap) and pentachlorophenol (Penta) treated pine stakes against decay and termite attack were compared at two test sites in Mississippi. Four different petroleum oils meeting AWPA Standard P9-A were used as carriers for these wood preservatives. After ten years exposure, the efficacy of Cu-Nap at a retention level of 0.05 pcf Cu was equivalent...
D D Nicholas, M H Freeman


Moulds and indoor climate in Denmark
2003 - IRG/WP 03-10488
Just like in many other countries after the oil crisis in 1972 Danish houses were tightened with the result that the relative air humidity rose considerably. The Ministry of Energy also demanded a lowering of the indoor temperature from 25°C to 20°C with the result that the relative air humidity rose even more. According to the latest survey 10% of Danish buildings are infected with moulds. Moul...
J Bech-Andersen, S A Elborne


A collaborative test to determine the efficacy of polyurethane coatings on wood samples exposed in the marine environment
1984 - IRG/WP 4113
Aims are: a) to determine the effectiveness of elastomeric polyurethane as a protective coating against marine wood boring animals in a range of tropical and tempreate sites; b) to compare the adhesion of polyurthane coatings on different wood species exposed in seawater; c) to record the severity of attack in failed samples and to identify the causal marine organisms....
R A Eaton


Ecotoxicological risks of anti-sapstain preservatives washed off from treated timber
2000 - IRG/WP 00-50144
A field method for ecotoxicity assessment of rain water wash-off from anti-sapstain treated timber was developed. In the course of this study freshly sawn timber treated with 1.5% Busan 30 L (reference preservative) and a control stack with untreated pine were exposed to weathering. The run-off water was ecotoxicologically tested with organisms from three trophic levels (Vibrio fischeri, Kirchneri...
G Aschacher, R Gründlinger


Short term preconditioning of preservative-treated wood in soil contact in relation to performance in field trials
2000 - IRG/WP 00-20185
The effect of pre-exposure to primary colonising micro-organisms on preservative-treated wood, prior to a basidiomycete decay test, was determined by preconditioning in two soil types. Scots pine EN 113 blocks treated with 3 model systems (a triazole, a copper quaternary compound and a copper boron triazole) were leached according to EN 84 and subjected to 6 weeks and 8 weeks burial in either John...
S Molnar, D J Dickinson


Sequential exposure of borate treated Douglas-fir to multiple Formosan subterranean termite colonies in a 40-week field test
1993 - IRG/WP 93-10006
Douglas-fir boards (ca. 74.5 g) pressure-treated with disodium octaborate tetrahydrate (DOT) retentions of 0 (controls), 0.88, 1.23, 1.60, or 2.10% (weight/weight) DOT were sequentially exposed to four active field colonies of Formosan subterranean termites, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), in an above-ground field test. Samples were placed in contact with each colony fo...
J K Grace, R T Yamamoto


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio


Collaborative soft rot tests: Summary of comments on 'Proposals for a standardized soil burial test'
1971 - IRG/WP 202
J G Savory


European standardization for wood preservation
1990 - IRG/WP 2359
G Castan


A standardised procedure for the treatment of timber with test chemicals
1986 - IRG/WP 2257
A procedure is described which allows the standardisation of sample handling and data manipulation during trials invastigating the treatability of timber with test chemicals. The use of computer software allows the data to be handled efficiently....
J Norton, A Zosars, L E Leightley


A note on testing the efficacy of wood preservatives above ground
1995 - IRG/WP 95-20078
A number of test methods have been used to evaluate the performance of wood preservatives in above ground situations. These have included EN 113 tests following natural exposure weathering (NEWT), L-joint or T-joint tests, lap-joint tests, and decking tests. A new test referred to as the A-frame test has been developed and is under evaluation. This is based on a sandwich-type test in which a thin ...
G R Williams, J A Drysdale, R F Fox


Multiple-Phase Pressure (MPP) Process: One-stage CCA treatment and accelerated fixation process. 5. Treatment of Sitka spruce and Scots pine
1999 - IRG/WP 99-40136
The suitability of the MPP Process for CCA treatment and accelerated fixation of species other than Radiata pine was assessed by pilot plant trials on UK-grown Sitka spruce (Picea sitchensis) and Scots pine (Pinus sylvestris). Pressure and vacuum kickbacks of spruce (14 l/m3) and Scots' pine (122 l/m3) were both substantially lower than that generated during treatment of radiata pine (369...
M E Hedley, K Nasheri, G Durbin


Report of field test results for dichloro-n-octyl-isothiazolone: A potential new wood preservative
1988 - IRG/WP 3495
In a previous report (IRG/WP/3306) we presented preliminary laboratory test results on 4,5-dichloro-2-n-octyl-4-isothiazolone (RH 287). Laboratory data indicated toxic threshold values for RH 287 ranging from 0.37 to 0.50 kg/m³. In this report we present field test results on an IRG L-joint test and an in-ground stake test for RH 287, pentachlorophenol and biocide free test units. (a) L-joint tes...
D E Greenley, B M Hegarty


Proposed test procedure to determine the effect of timber substrate on the effectiveness of a copper/chrome/arsenic preservative in seawater
1975 - IRG/WP 411
R A Eaton


IRG test of preservative-treated hardwoods with particular reference to soft rot. Report on condition of specimens installed in Victoria, Australia
1983 - IRG/WP 3269
G C Johnson, J D Thornton


IRG WG III - World-wide co-operative field experiment
1977 - IRG/WP 383
R Cockcroft


Screening potential termiticides: Some thoughts and suggestions on methodology
1988 - IRG/WP 1363
While laboratory bioassays on the efficacy of potential termiticides against subterranean termites continues both to dominate and influence research efforts, suggestions are presented for the need to develop laboratory bioassays that more closely simulate "natural conditions". Not only is this considered desirable, but it will offer more confidence in laboratory and field evaluations and their ana...
J R J French