IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 273 documents. Displaying 25 entries per page.


The influence of drilling patterns on the distribution of toxicants from Polesaver Rods in hardwood poles
1994 - IRG/WP 94-30051
Polesaver Rods are solid rods of wood preservative that are used as a groundline maintenance treatment to control biodeterioration in hardwood transmission poles in Australia. The rods are inserted in holes that are drilled in a prescribed manner to distribute the toxicants into the critical groundline region of the poles. To determine the influence of drilling patterns on the distribution of toxi...
W D Gardner, C N McEvoy


Study of modulus of rupture, circumference taper, sapwood thickness and CCA treatment of Norwegian origin Pinus sylvestris poles
1994 - IRG/WP 94-20054
Nondestructive strength testing with Pilodyn (6J) of Norwegian Pinus sylvestris poles revealed effective modulus of rupture (MOR) of 54.39 N/mm² at wet conditions after CCA-C treatment and circumference measurement revealed circumference taper of 0.021 m/n. Sapwood thickness or penetration of CCA-C study revealed that 77% poles were with sapwood thickness equivalent to 39.6% of radius of poles an...
A K Lahiry, S Begum, G N M Ilias, M A B Fakir, R U Hafiz


Comparison of the anti-fungal efficacy of Cobra with drill perforation on oscillating pressure treated spruce transmission poles -Laboratory test
1988 - IRG/WP 3469
A laboratory method for measuring the depth of penetration of the fungicidal concentrations effective against basidiomycetes (brown rot) was developed. The tests on CCB oscillating pressure treated spruce transmission poles have shown that the depth of salt penetration can be increased by about 10 mm by a drill perforation before the impregnation. An even better penetration is reached, however, if...
E Graf, B Zgraggen


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Wood preservation requirements in Queensland, Australia
1983 - IRG/WP 3227
In Queensland the preservative treatment and utilization of timber must comply with the Timber Users' Protection Act. Preservative retention levels and penetration patterns must be complied with. Analytical zones are specified for removing samples for chemical analysis of preservative retention. The required retention levels have been expressed as percent weight of oven dry wood weight. T...
L E Leightley, M J Kennedy


Glued laminated poles - Progress report after 18 years' testing
1998 - IRG/WP 98-20140
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line in Vuollerim in northern Sweden in order to study their resistance against biological degradation. The tests have shown that the best performance will be obtained if each laminate is first treated with a water-bo...
Ö Bergman, J Jermer


Glue laminated poles - Progress report after 12 years' testing
1992 - IRG/WP 92-3685
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line just south of the Arctic circle in order to study their resistance against biological degradation. The tests have shown that the comparatively best performance will be obtained if each laminate is first treated wi...
J Jermer, Ö Bergman


Studies and experiences of occurrence and development of soft rot in salt-treated poles of pine (Pinus sylvestris) installed in Swedish transmission lines in the years 1940-1945
1977 - IRG/WP 277
The present work describes the result of microscopic examinations of some 2,000 borings extracted from 20 to 23-year-old salt-treated poles (Scots pine) from the southern and central parts of Sweden. The purpose was to map out the occurrence of soft rot in Sweden and its influence on the mechanical strength of the poles as well as to contribute to the development of new and more satisfactory metho...
H Friis-Hansen


Borates as wood preserving compounds: The status of research in the United States
1989 - IRG/WP 3542
This paper describes the extensive, on-going cooperative research effort among government and university research laboratories and industry to fully evaluate the potential for borates as wood preservatives in the United States. Research is discussed in terms of laboratory evaluations, field testing and mill trials, pilot plant pressure treatment studies, and remedial treatments. Future research pl...
H M Barnes, T L Amburgey, L H Williams, J J Morrell


Statement on laws relating to wood preservation in Brazil
1977 - IRG/WP 399
A set of copies of the laws relating to wood preservation in Brazil (in Portuguese) have been deposited with the IRG Secretariat. Generally speaking, it can be said that all public constructions have to comply with the laws that have been laid down. All organisations (governmental and private) which produce or apply wood preservatives are registered. The private sector is not obliged to abide by t...
P Karstedt


In vivo growth study on two gymnosperms and four angiosperms for REB wood poles
1998 - IRG/WP 98-10246
Revealed that the highest growth rates and pole yield in two plantation sites in Bangladesh are significant with 2.06 cm/y in diameter, 0.97 m/y in height and 90% pole yield within 19y in Pinus caribaea; 1.96 cm/y, 0.91 m/y and 100% pole yield within 15y in Xylia dolabriformis; 1.88 cm/y, 0.91 m/y and 22% pole yield within 13y in Dipterocarpus turbinatus; 1.64 cm/y, 0.82 m/y and 28.75% pole within...
A K Lahiry


Biological control of internal decay in Scots pine poles: A seven year experiment
1992 - IRG/WP 92-1529
The interactions between key fungi were monitored, by non-destructive and destructive sampling methods, during the course of an experiment on the effectiveness of Scytalidium sp. and Trichoderma spp. for eliminating established infections of Lentinus lepideus (Fr. ex Fr.) Fr. in creosoted Pinus sylvestris poles. Although extensively isolated at the beginning and end of the experiment, Trichoderma ...
P I Morris, D J Dickinson, B Calver


Distribution of boron from fused borate rods in Douglas-fir transmission poles
1996 - IRG/WP 96-30112
The diffusion of boron from fused borate rods (disodium octaborate tetrachydrate) was monitored over 42 months in CCA-treated Douglas-fir transmission poles. The boric acid equivalent was estimated by the curcumin/salicylic acid color test on increment cores removed from the poles. Moisture content of the poles was quite variable but was always above 20 percent. The percent of increment core lengt...
T L Highley, F Green III, W F Finney


Wood preservation research in Tanzania: Priorities and challenges
1988 - IRG/WP 3462
Tanzania provides some of the highest rates of wood deterioration in service leading to alarming economic losses and yet no serious concern is shown in search for solutions to the problem. The paper attempts to point out some of the priority areas in the field of wood preservation research that demand urgent attention if timber is to be used judiciously in this country. An account is given of the ...
K K Murira, R Cockcroft


Treatment groups and remedies for CCA treated hardwood and softwood poles
1999 - IRG/WP 99-40142
Different hardwood and softwood species from Bangladesh and Bhutan was investigated regarding density, green fiber stress, natural durability of heartwood and CCA treated sapwood, CCA treatability grades, sapwood thickness, and kiln-drying properties for long term use as electric poles. These properties along with the past service records for nineteen years, separated ten heardwood and five softwo...
A K Lahiry


The potential use of impregnated coconut wood for power line poles in rural areas of Java
1980 - IRG/WP 3130
Electrification of rural areas in Java needs thousands of power line poles which are relatively cheap in price, but have adequate strength and are fairly durable. A choice of wood species is available in the country. One alternative is coconut wood found in abundance in the villages. This may give a solution to Java's needs since supplies are readily available almost everywhere. Based on ...
H Yudodibroto


Studies in an accelerated soil bed facility on the decay susceptibility of U.K. grown spruce and pine poles treated with copper/chrome/arsenic (CCA) by pressurised sap-displacement. Part 1: Setting up of soil beds and initial soft rot results
1990 - IRG/WP 2344
The paper describes the methodology used in the construction and early operation of an accelerated soil bed facility used to examine the decay susceptibility of U.K. grown Scots and Corsican pine and Sitka and Norway spruce treated with C.C.A. by high pressure sap-displacememt. The design and control of the facility as well as the preparation, soil exposure and soft rot decay analysis of quarter p...
A Bruce, S D Hainey, G M Smith, B King, P D Evans


Fluoride and chromium concentrations in soil adjacent to remedially treated distribution poles
1996 - IRG/WP 96-50066
Soils adjacent to Rentex treated 'on-line' distribution poles were analysed for total fluoride and chromium content for comparison with background values of these elements. Soil samples 6 cm and 25 cm downslope of selected poles were recovered at 1 week, 1 month, 6 and 12 months after treatment. Background soil samples were taken 50 m from the poles at sampling times. Fourteen po...
D C R Sinclair, G M Smith, A Bruce, H J Staines, P Durrant


Quantification of creosote migration down wooden poles and the prevention of its depletion during flood irrigation
1994 - IRG/WP 94-50032
Polyethylene field liners heat-shrunk onto soil-contact surfaces prevented decay of creosote-treated Eucalyptus grandis vineyard poles under flood-irrigation. The present work quantified losses of creosote from these poles after six and 24 months' service. After six months' service the mean creosote retention of unlined poles above the ground line was 12.62% (m/m dry wood), with ...
M Behr, A A W Baecker


A 53-year old field trial to evaluate the performance of a range of chemical treatments on eucalypt poles
1989 - IRG/WP 3526
Hardwood pole stubs of Eucalyptus maculata, Eucalyptus pilularis, Eucalyptus saligna and Eucalyptus paniculata were examined for termite attack and fungal decay after 53 years in ground contact. The trial compared eight different chemical treatments with untreated pole stubs of the four species investigated. Untreated Eucalyptus paniculata, a Class I durability species, performed particularly well...
R S Johnstone, R A Eaton


The effect of moisture content on the electrical resistance of timber as detected by a pulsed current reistance meter (Shigometer)
1984 - IRG/WP 2212
The literature concerning the use of the Shigometer® for detecting decay in standing trees and wood poles is reviewed and the differences of opinion over the effect of timber moisture content on electrical resistance are highlighted. A simple experiment designed to test this effect is described and the implications of the results for testing poles in service are discussed. There was a large diffe...
P I Morris, D J Dickinson


Shorter-term biological control of wood decay in pre-seasoning pine roundwood as an alternative to chemical methods
1992 - IRG/WP 92-1555
Previous studies on the long-term control of decay in creosoted transmission poles, using Trichoderma and other antagonistic moulds, have met with limited success. However, it is possible biological control is more suited to control of decay on shorter time scales. An earlier study, focusing on pre-seasoning treatment of transmission poles showed that favourable porosity increases could be brought...
M W Schoeman, D J Dickinson


LCA examination of preservative treated timber products and alternatives; initial results
1995 - IRG/WP 95-50040-04
Co-operative development of an LCA methodology suitable for application to preservative treated products has been carried out, based on scoping assessments of two products, CCA treated fenceposts and creosote treated distribution poles. The general results of these scoping exercices are described, based on the CCA case study. These include the identification of critical stages in the life-cycle on...
W Hillier, R J Murphy, D J Dickinson, J N B Bell


The use of fumigants for controlling decay of wood: a review of their efficacy and safety
1989 - IRG/WP 3525
Volatile agricultural chemicals (fumigants) such as chloropicrin (trichloronitromethane) and sodium n-methyldithiocarbamate have been used in the United States for controlling internal decay of large dimension wood products for over 20 years. This usage has been concentrated in the electric utility industry, but fumigants are increasingly applied to protect bridge timbers, marine piling, and even ...
J J Morrell


Quantification of creosote and fluoride in remedially-treated poles
1997 - IRG/WP 97-40097
Three creosoted transmission poles were put into service in 1961 and they were subsequently remedially-treated with a proprietary fluoride remedial paste formulation in 1981. The poles were removed from service in 1996 and their ground-contact regions were analysed for creosote and fluoride contents. It was found that the poles were undecayed. Creosote retentions decreased down the profiles of the...
B P Hill


Previous Page | Next Page