IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 619 documents. Displaying 25 entries per page.


Model of termite distribution in Portugal - Follow-up
2003 - IRG/WP 03-10470
In Portugal, subterranean termites of the genus Reticulitermes are indigenous and a well-established pest of wood in service. Mapping their distribution has therefore become important. A field sampling campaign was established along a North-South transect based on 50x50 km cells (Universal Transverse Mercator grid system, UTM). A variety of typical habitats, ranging from forest sites of Eucalyptu...
T Nobre, L Nunes


Termite physical barriers: Update on retrofitting Granitgard around 'mock-up' buildings after three years
1995 - IRG/WP 95-10118
This field experiment was installed three years ago (March 1992) to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite aggregate or "screenings", as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and ...
B M Ahmed, J R J French


Preference of the Formosan subterranean termite for wood previously damaged by conspecifics
1988 - IRG/WP 1338
In a laboratory choice test, groups of termites from five colonies of Coptotermes formosanus Shiraki were presented with wood blocks which had sustained previous termite damage: 1) by nestmates, 2) by conspecifics from another colony, 3) by another termite species, Reticulitermes virginicus Banks, and 4) no damage. Coptotermes formosanus preferred wood previously damaged by conspecifics over that ...
J P La Fage, K S Delaplane


Survey of maintenance management of a residence
2001 - IRG/WP 01-10405
The following points were clarified from the responses to the questionnaire. Termite damage was most common in the bathroom, washroom, and entrance, in that order. Termite damage was most commonly found beneath floors, followed by floor surfaces, and inside walls, in that order. Damage in framing was minimal. Damage in all structural components was most common in the Kyushu region, with the most s...
Y Yamaguchi, M Azuma, Y Hikita, K Nishimoto


Termites in Eastern Canada: A brief review and assessment
1987 - IRG/WP 1333
The distribution of termites in Canada is reviewed, with particular emphasis on the eastern subterranean termite Reticulitermes flavipes (Kollar) in Ontario province. Municipal and provincial termite control programs are discussed and current treatment practices are described. Previous research on Reticulitermes flavipes in Ontario is briefly reviewed, with reference to a number of unpublished rep...
J K Grace


Effect of treatment process on performance of copper-chrome-arsenate. Part 2: Field stake tests
1995 - IRG/WP 95-40046
Pinus radiata sapwood stakes 20 x 20 x 400 mm³ were treated with CCA Type C using a range of concentrations and three treatment processes; Bethell, Lowry and Rueping. Preservative retention was determined by chemical analysis of treated material. Following fixation stakes were installed in a randomised plot in the Whaka graveyard located on the FRI campus. Stakes were inspected at yearly interval...
M E Hedley, J Anderson, J B Foster, B E Patterson


Estimation of the population of a sound colony of Coptotermes lacteus (Froggatt)
1988 - IRG/WP 1353
Selecting an area with a high termite hazard is deemed essential in locating field sites in order to screen potential termiticides and wood preservatives. Yet, quantifying termite populations in such sites remains imprecise. There are major problems associated with estimating populations of termites in mound colonies (either free-standing or in trees), and these are briefly discussed. In this pape...
D M Ewart, J R J French


Sampling rates and the probability of detecting defective treatment in the sampling of preservative treated timber
1987 - IRG/WP 2277
When attempting to enforce standards of penetration and retention set for treated timber, the regulating authority must establish a sampling or inspection scheme which will prevent large quantities of substandard product entering the market. On the other hand, the scheme should not penalise treaters for the small quantities of such material which are inevitably produced by any industrial process. ...
M J Kennedy, L E Leightley


A laboratory bioassay on the termiticidal efficacy of a chlorothalonil formulation and a chlorothalonil plus chlorpyrifos formulation to Mastotermes darwiniensis Frogatt
1993 - IRG/WP 93-30004
Results of a laboratory bioassay on the efficacy of two preservative formulations (chlorothalonil in oil; chlorothalonil plus chlorpyrifos in oil) to the Australian subterranean termite Mastotermes darwiniensis Froggatt are given. Specimens of Pinus radiata D. Don sapwood were treated to three retentions of each formulation to achieve 3.2, 6.4 and 12.8 kg/m³ of chlorothalonil a.i. and 3.2 + 0.2, ...
J W Creffield, N Chew


European laboratory termite testing
1986 - IRG/WP 1299
As with all testing of wood preservatives the evaluation of the resistance to termites of treated wood requires methodology which is approriate to, and can be readily extrapolated to, the practical situation. Thus not only must the variations in possible treatment systems be taken into account (eg dip, brush or pressure application) so too must the range of termite species and the type of exposure...
R W Berry


Resistance of painted wood to mould fungi. Part 2. The effect of wood substrate and acrylate paint systems on mould growth
1997 - IRG/WP 97-10234
Resistance of acrylate paint systems on different types of pine and spruce sapwood to mould fungi was studied. Dipping into the preservative prior to painting, a primer with and without a fungicide (propiconazole + IPBC 0.50 + 0.2%) and a topcoat with and without a fungicide (propiconazole + IPBC 0.25 + 0.12%) were combinations of the treatments studied. The efficacy of the treatment systems varie...
H Viitanen, P Ahola


Risk reduction from curative treatments, restoration and maintenance of building and individual housing - simple precautions that make the difference
2005 - IRG/WP 05-50224-15
This document explores the potentialities of risk reduction, from activities of remediation in construction, developped at small scale by professionals or individuals on targets like moulds, rots, termites and other wood destroying insects, with products distributed for professional or do-it-yourself purposes. At the first stage, an inventory of the type / interest of products / processes is carri...
G Ozanne


Inhibition of termite damage by N'N-napthaloylhydroxyamine (NHA): Reticulotermes flavipes (Kollar) vs. Coptotermes formosanus Shiraki
2000 - IRG/WP 00-10354
The calcium precipitating agent NHA has been shown to protect southern yellow pine (SYP) from wood decay and termite damage comparable to CCA in field tests (Gulfport, MS) for two years (Crawford and Green, 1999). In a collaborative study, SYP wood blocks were vacuum treated with three concentrations of aqueous NHA and exposed in a no-choice test to Eastern subterranean termites (FPL, USA) and For...
F Green III, S T Lebow, T Yoshimura


A status report on code of good practices
1991 - IRG/WP 3679
Code of Good Practices - Anti Sapstain documents, presented to IRG meetings in the past, are the basic documents for health and safety of the workers and the environment in Canada. The BC Ministry of Environnment has now issued regulations in the area of effluent discharge. While Pentachlorophenols (PCP) are not used by the industry, the documents are still used as a guideline document for the oth...
V N P Mathur, G Das


Bioassays of extracts from scaly ash (Ganophyllum falcatum B1) against the subterranean termite Coptotermes acinaciformis (Froggatt)
1983 - IRG/WP 1206
Scaly ash, Ganophyllum falcatum B1. wood shavings were extracted by methanol, and fractionated with ethyl acetate, diethyl ether and water, and the anti-termitic properties of these materials bioassayed against the subterranean termite Coptotermes acinaciformis (Froggatt). Laboratory techniques were developed to overcome the problem of limited extractive materials. The results of the various bioas...
J R J French, J P Robinson, J W Creffield


Worldwide in-ground stake test of acetylated composite boards
1997 - IRG/WP 97-40088
Acetylated wood composite stakes are being tested in ground contact (graveyard test) in seven fields around the world. Three types of acetylated wood composites were prepared: spruce fiberboard in Sweden, aspen fiberboard in Madison and rubber wood particle board in Indonesia. Two levels of acetylation were used, a high level of ~20% acetyl content and a low level of 10% acetyl content. Control bo...
R M Rowell, B S Dawson, Y S Hadi, D D Nicholas, T Nilsson, D V Plackett, R Simonson, M Westin


The case for non-chemical termite barriers in termite control
1989 - IRG/WP 1381
A brief outline of current non-chemical barriers in subterranean termite control and their use in Australia is presented. Recent use of non-chemical barriers in Hawaii has led to their evaluation in termite control here and elsewhere. In Australia, preliminary laboratory and field experiments have shown similar results to those found against Coptotermes formosanus in Hawaii, namely, Australian Cop...
J R J French


A Long-term Observation of Termite Activity in The Nest by Continuous Acoustic Emission (AE) Monitoring
2003 - IRG/WP 03-20280
In order to evaluate the influence of temperature on the termite activity, acoustic emission (AE) monitoring was applied to two nests of Coptotermes formosanus SHIRAKI; a nest in the stem of a standing tree and a nest in the underground of a wooden house, respectively. Temperature change in and around the nests were continuously measured for about one year using thermocouples at four points; the c...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura


Case histories involving attempts at identifying infestations, determining the source and controlling the Formosan subterranean termite in Atlanta, Georgia USA
2000 - IRG/WP 00-10342
The University of Georgia Department of Entomology and the Georgia State Department of Agriculture have been involved in identifying and working with Pest Control Operators and homeowners dealing with Formosan subterranean termite infestations in the Atlanta, Georgia metropolitan area since 1993. Our involvement with seven separate infestations is outlined in this paper in the form of case histori...
B T Forschler, J Harron, T M Jenkins


The efficacy of remedial treatments for controlling fungal decay in window millwork used in the United States
1987 - IRG/WP 3432
Conventional window millwork was subjected to basidiomycete decay by inoculation and sampled for active growth of the decay fungus before and eight months after remedial preservative treatment with fused disodium octaborate rods (IMPEL) at boric acid levels of 1.5 and 4.0 kg/m³ or liquid bifluoride injections (IMPROSOL) at 1 kg/m³. The elimination of decay fungus after remedial treatment was nea...
M G Dietz, E L Schmidt


Preservative treatments of window components with a water-based borate formulation
2000 - IRG/WP 00-40171
Factory finished window joinery components were treated with an aqueous borate preservative in order to investigate penetration and retention levels, associated drying times; and the potential impact of using a water-based treatment on finished items. It was found that by using borates applied by light double vacuum schedules, it was possible to meet standards for penetration and retention, to air...
J Jermer, J D Lloyd


A termite field test with diffusion treated lumber
1991 - IRG/WP 3648
Douglas fir lumber, diffusion treated with concentrated sodium octaborate solutions, was tested against Coptotermes formosanus in an above ground field test wherein the samples were not exposed to a direct leaching hazard during the test period. After 2.5 years exposure, the untreated control samples were almost completely destroyed while poorly treated controls pressure treated with chromated cop...
K J Archer, D A Fowlie, A F Preston, P J Walcheski


Incorporation of phenyl boronic acid treatment with vapor phase formalization
1997 - IRG/WP 97-40083
Phenylboronic acid (PBA) treatment was incorporated with vapor phase formalization (VPF) in order to increase dimensional stability and boron fixation as well as enhancement of biological resistance. Five and ten hours VPF were applied after PBA treatment as 0.34, 0.50, 1.00 and 2.00% concs. aqueous solutions. Anti swelling efficiency (ASE) attended to 71% in specimens impregnated with 0.50% PBA s...
M K Yalinkilic, S Yusuf, T Yoshimura, W-Y Su, K Tsunoda, M Takahashi


The effectiveness of deltamethrin against subterranean termites (final report)
1993 - IRG/WP 93-30011
Two series of block tests of Pinus sp were treated by dipping them for 1 (one) minute in a solution with 0.015 (w/w) and 0.05 (w/w) of deltamethrin, respectively. In both cases, an average retention of 47 kg/m³ (0.32 l/m) was reached. One part of the block tests remained under laboratory conditions during 9 months, and the other was stored during equal period of time in a theater basement submitt...
P A Zanotto


Termite and decay resistance of particleboard composed of white cypress pine and radiata pine
1997 - IRG/WP 97-10200
Phenol-formaldehyde bonded particleboard was manufactured from blends of non-durable radiate pine (P. radiate) and heartwood of the naturally durable species, white cypress pine (C. glaucophylla). Board specimens were subjected to bioassays using two termite species, M. darwiniensis and C. acinaciformis, and the basidiomycete fungi, C. puteana and P. ostreatus, and the durability of specimens was ...
P D Evans, J W Creffield, J S G Conroy, S C Barry


Previous Page | Next Page