IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 437 documents. Displaying 25 entries per page.


A laboratory bioassay on the termiticidal efficacy of a chlorothalonil formulation and a chlorothalonil plus chlorpyrifos formulation to Mastotermes darwiniensis Frogatt
1993 - IRG/WP 93-30004
Results of a laboratory bioassay on the efficacy of two preservative formulations (chlorothalonil in oil; chlorothalonil plus chlorpyrifos in oil) to the Australian subterranean termite Mastotermes darwiniensis Froggatt are given. Specimens of Pinus radiata D. Don sapwood were treated to three retentions of each formulation to achieve 3.2, 6.4 and 12.8 kg/m³ of chlorothalonil a.i. and 3.2 + 0.2, ...
J W Creffield, N Chew


Laboratory evaluation of borate formulations as wood preservatves to control the subterranean termite coptotermes acinaciformis (isoptera: Rhinotermitidae) in Australia
2001 - IRG/WP 01-30266
The termiticidal efficacy of Borocol (sodium octaborate tetrahydrate), boric acid, bore-ester-7 and tri- methyl borate was evaluated in laboratory bioassays against Coptotermes acinaciformis (Froggatt). Seasoned sapwood blocks of Pinus radiata D. Don, and Eucalyptus regnans (F. Muell) were impregnated with the various borate compounds. There were marked differences in mass loss and mortality rate ...
B M Ahmed, J R J French, P Vinden


Chemical evaluation of borate treated pine sapwood attacked by the subterranean termite Coptotermes acinaciformis
1993 - IRG/WP 93-20003
Sapwood of hoop (Araucaria cunninghamii Ait. ex D. Don) and slash (Pinus elliottii Englem.) pines were treated by Vacuum Pressure Impregnation (VPI) to provide test specimens. The concentration of boron was defined by chemical analyses of the timber, in the zone of primary attack by the termite being bioassayed. A common method of definition of preservative retention, weight uptake of preservative...
A R Moffat, B C Peters


Establishing standard principles for laboratory bioassays of termiticides with subterranean termites - progress, problems and prospects
1993 - IRG/WP 93-10013
Laboratory bioassays of termiticides, including wood preservatives, aim to give an indication of the likely concentrations effective in preventing damage to timber products and other materials in the field. In laboratory bioassays field conditions should be simulated as closely as possible. With a wide range of procedures in use around the world it may often be difficult to compare results between...
M Lenz, J W Creffield, Zhong Yun-hong, L R Miller


Estimation of oral toxicity of boron as a bait toxicant and the trophallactic effects between individual members of termite colonies.
2003 - IRG/WP 03-10495
In recent years, because of the favourable environmental characteristics of boron, researchers in the wood preservation industries have refocussed on the use of boron as a major wood preservative against wood-destroying insects. Currently the greatest use of boron compounds is in remedial treatments. Boron has been found to have slow-acting toxicity against subterranean termites. Because of thi...
B M Ahmed


Protection of southern pine using N,N-Napthaloylhydroxylamine: Field tests, soft-rot cellars and aquatic bioassay leach testing
1999 - IRG/WP 99-30204
Recent environmental restrictions are limiting the use of broad-spectrum biocides for wood preservation. There is an urgent need for new, sharply targeted, environmentally benign wood preservatives. N'N-Napthaloylhydroxylamine (NHA), a water-soluble calcium-precipitating agent, has been shown to inhibit decay by brown-rot and white-rot fungi in soil-block tests and prevent damage by Easte...
D M Crawford, F Green III


Laboratory evaluation of the termiticidal effectiveness of TanalithÒ 3485
1995 - IRG/WP 95-10109
The termiticidal effectiveness of the copper azole TANALITH 3485 was evaluated with the benchmark preservative TANALITH C in a laboratory bioassay using two species of subterranean termites, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Retentions of TANALITH 3485 tested were 0.15, 0.24, 0.285 and 0.40% m/m Cu and for TANALITH C 0.025, 0.05, 0.08 and 0.095% m/m Cu. Un...
J W Creffield, J A Drysdale, N Chew, N-K Nguyen


Performance of sintered glass screening as a potential physical barrier against subterranean termites in the laboratory and after 4 years of field test
2008 - IRG/WP 08-10646
This paper describes the performance of sintered glass screenings as a potential physical barrier against the subterranean termites, Coptotermes acinaciformis and Mastotermes darwiniensis in the laboratory and after four years of field testing in active above-ground mound colonies of Coptotermes lacteus. The laboratory results suggest that sintered glass is a viable control option against Copto...
J R J French, B M Ahmed (Shiday)


Comparative response of Reticulitermes flavipes and Coptotermes formosanus to borate soil treatments
1991 - IRG/WP 1486
Eastern (Reticulitermes flavipes [Kollarl]) and Formosan (Coptotermes formosanus Shiraki) subterranean termite workers (Isoptera: Rhinotermitidae) were exposed to borate-treated sand in an indirect exposure tunneling assay in the laboratory. In the ten day assay period, both termite species readily penetrated sand containing 5000, 10000, or 15000 ppm (wt. of compound / wt. of sand) disodium octabo...
J K Grace


A rapid field bioassay technique with subterranean termites
1983 - IRG/WP 1188
Details are summarised of a field procedure which is designed to ensure continuous exposure to a replenishing termite biomass. After pre-baiting to determine the presence and identification of a termite hazard, test specimens (35 x 35 x 250 mm³) are installed vertically in the ground adjacent to and in contact with bait specimens of the same dimensions and interconnected by susceptible feeder str...
C D Howick, J W Creffield


Problems caused by termites in buildings in the State of Sao Paulo
1976 - IRG/WP 150
Termites are the main insects attacking buildings in the State of Sao Paulo - Brazil. Their attack occurs in wood and wooden materials as well as paper, textile, leather and so on....
M S Cavalcante


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Third update and first report
1996 - IRG/WP 96-10174
At the 24th annual meeting of IRG in Orlando, USA, in May 1993 an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives, copper-chrome-arsenic (CCA) and copper naphthenate (Cu-Na) against the subterran...
J R J French


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Trials on the field control of the Formosan subterranean termite with Amdro® bait
1982 - IRG/WP 1163
Amdro® - treated paper towels were introduced into two field colonies of the Formosan subterranean termite in Hawaii. At the concentration of 180 ppm, the toxicant bait was ineffective one month after the introduction. At higher concentrations (> 6,400 ppm), the baits were eaten initially; however, one week after introduction, termites avoided or covered the baits. The 15,000 ppm baits supress...
N-Y Su, M Tamashiro, J R Yates III


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Termite resistance of pine wood treated with chromated copper arsenates
1997 - IRG/WP 97-30128
Two four-week, no-choice laboratory tests were performed with CCA-treated southern yellow pine and radiata pine against Formosan subterranean termites, Coptotermes formosanus. CCA retentions as low as 0.05 kg/m3 (0.03 pcf) provided protection from all but light termite attack (rating of 9 on a 10-point visual scale). Similar and consistent light attack on wafers containing retentions as high as 6....
J K Grace


Termite trail-following substances in Houttuynia cordata
2001 - IRG/WP 01-10409
Termite trail-following active compounds in the plant, Houttuynia cordata Thunb., were studied by a combination of chemical analyses and bioassay using Coptotermes formosanus Shiraki as a test termite. We have found that termites were attracted to methanol extracts from H. cordata. The n-hexane(Hex) extracts, that showed a trail-following activity, were fractionated by a silica-gel column chromato...
W Ohmura, K Yamamoto, M Saegusa, T Ohira, A Kato


Evidence supporting the use of termite baiting systems for long-term structural protection
2000 - IRG/WP 00-10377
The efficacy of the Sentricon Colony Elimination System containing Recruit II termite bait (0.5% hexaflumuron) in controlling active subterranean termite infestations has been demonstrated in numerous studies. This baiting system and other termite baiting systems are now widely used, and generally accepted, tools for remedial termite control in North America, Hawaii, and other parts of the world. ...
J K Grace, N-Y Su


Physical and biological properties of albizzia waferboards modified with cross-linking agents
1995 - IRG/WP 95-40043
Chemically-modified low-density waferboards with cross-linking agents were produced using a fast-growing species of hardwood albizzia (Paraserienthes falcata Becker) as a raw materials and isocyanate resin as a glue adhesive. For the chemical modification, the vapor-phase formalization of the boards and the pad-dry-cure treatment of wafers with cross-linking agents were employed. The vapor-phase f...
S Yusuf, Y Imamura, M Takahashi, K Minato


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Biological control of the Formosan subterranean termite Coptotermes formosanus Shiraki
1971 - IRG/WP 100
M Tamashiro, J K Fujii, P Lai, T E Richardson


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Next Page