IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 489 documents. Displaying 25 entries per page.


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Comments on soft rot attack in timbers treated with CCA preservatives: A document for discussion
1982 - IRG/WP 1167
This paper is not based on any particular results but rather on several observations of soft-rot during many years of studies, and on a review of the existing literature. The short time available has unfortunately not permitted a detailed review of the literature. Data and knowledge of important facts are lacking for several aspects of soft-rot attack and for reactions occurring in the wood as a r...
T Nilsson


Relationship between the bending strength and the degree of termite attacks on western hemlock by Coptotermes formosanus Shiraki
1990 - IRG/WP 1434
For the examination of the relationship between the bending strength and the degree of termite attacks, Western Hemlock (Tsuga heterophylla Sarg.) was used. Sixty specimens (4.5 x 4.5 x 82 cm³) were attacked by termites at the culture room of Coptotermes formosanus Shiraki. The termites were introduced on the central parts (10 cm) of specimens. In the case of the 2 points loading, the bending mom...
K Suzuki, T Tanaka


Nondestructive assessment of biodegradation in southern pine sapwood exposed to attack by natural populations of decay fungi and subterranean termites
1994 - IRG/WP 94-20042
Field methods for evaluating decay resistance of experimentally treated materials lack a means for quantitative measurement of residual strength. Quantitative relationships between speed of impact-induced waves travelling parallel to the grain and residual compressive strength have been demonstrated in softwood attacked by brown rot-decay fungi, but the effects of termites have not been documented...
R C De Groot, R J Ross, W Nelson


The density factor in termite bioassays
1985 - IRG/WP 1252
The initial and final floor surface and food block surface actually used by termites in a small container were converted to estimates of "Living Space" and "Feeding Space" densities for 1/32 to 1½ g groups of termites. The termites were provided with blocks of blotter paper as a food supply. Except where 1½ g groups exhausted the food, the survival of termites was uniformly high (averaging >9...
G R Esenther


Biological resistances of wood-metaborate composites using the borax solution system
2001 - IRG/WP 01-30259
Combinations of wood and metaborate composite were prepared from sapwood specimens of Japanese cedar (Cryptomeria japonica) and the borax and metallic salts system using the diffusion-penetrated process. Wood-metaborate composites were produced as follows: water-saturated specimens were first impregnated by a saturated borax solution and then diffuse-penetrated with Zn2+, Ca2+, or Pb2+ solution. B...
Liang Lin, T Furuno


The importance of blue stain attack for the colonization by wood-rotting fungi of wood not in contact with the ground
1988 - IRG/WP 1349
When used in constructions not in contact with the ground, wood has been shown often to proceed from blue stain to moulds. The appearance of wood rotting fungi is normally delayed. Solid wood artificially inoculated with the blue stain fungus Pullularia pullulans was shown to permit germination of Pycnoporus cinnabarinus basidiospores. This was demonstrated by the use of an indirect and a direct b...
J Bjurman


A real scale evaluation method and results on termite resistance of housing wall systems and floor framings
1999 - IRG/WP 99-10314
For evaluating the termite resistance of real scale houses especially housing wall systems and floor framings, a experimental building was prepared. After initial feeding of termite, this house was constructed. In this experimental building, several parts which were built by different wall systems and floor framing. The room temperature of these parts were controlled. Water can be provided in the ...
K Suzuki, K Okada, K Hagio, Y Tanaka


Laboratory trials of biological control agents against subterranean termites
1991 - IRG/WP 1475
To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiomycetes, were used to challenge the test termite species, Coptotermes formosanus and Reticulitermes speratus. Test fungi were allowed grow and completely in Petri dishes. To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiom...
K Suzuki


Categories in wood preservation hazard, risk, and use
1994 - IRG/WP 94-20048
In various countries hazard-, risk-, or use-categories have been established. The different terms seem to be only a sophisticated language problem, but they are rather a basic principle of the philosophy of wood preservation which is going to obtain importance with respect to the low reputation of chemical wood preservatives in an increasing number of countries. Whilst hazard signifies the fact th...
H Willeitner


Biological degradation resistance of wood acetylated with thioacetic acid
1983 - IRG/WP 3223
Chemically, modification of wood is being considered as an alternative to conventional preservation by toxic chemicals. Acetylated wood has been reported to be quite resistant to most biodegrading organisms at weight percent gains (WPG) around 15-19. The conventional acetylation techniques with acethic anhyrdride result in generation of acetic acid. However, acetylation with thioacetic acid overco...
S Kumar, S C Agarwal


Protection of freshly felled timber against attack by bark boring insects
1981 - IRG/WP 1143
This report describes two experiments with the insecticide formulation Perigen, which contains the synthetic pyrethroid permethrin. At 0.2% w/v active ingredient individual logs were protected against bark boring beetles for 18 weeks. At 0.3% w/v active ingredients Perigen gave similar protection against insect attack to stacks of recently felled unbarked pine logs. This protection was at least eq...
J Dominik, P R Skidmore


An anti-termite formulation for soil treatment with natural products and its efficacy against Coptotermes formosanus Shiraki
2003 - IRG/WP 03-30319
An anti-termite formulation of an environmental conservation type for soil treatment was developed. The formulation was composed of decanoic acid (n-capric acid, an fatty acid derived from coconut oil with ten carbons) as an active ingredient and other natural products. Experiments to examine the efficacy of the formulation against Coptotermes formosanus Shiraki were conducted at the termite field...
S Yoshida, T Nakagaki, A Igarashi, A Enoki


Laboratory evaluation of JB-TB003 as potential bait toxicant against the subterranean termite, Coptotermes acinaciformis in Australia. subterranean termite, Coptotermes acinaciformis in Australia
1997 - IRG/WP 97-10214
In this laboratory evaluation, Coptotermes acinaciformis actively attacked in the first week of testing Pinus radiata wood blocks (50 x 25 x 15 mm3) treated with concentrations of JB-TB003 (i.e. 25, 50, 100, 200 and 400 ppm); the blocks with highest concentration were the most attractive. Results were similar whether blocks were leached or unleached. The earliest mortality occurred in the 400 ppm ...
B M Ahmed, J R J French, A R Valcke, P Blunt


The effect of boric acid on the protozoan numbers of the subterranean termite, Reticulitermes lucifugus
1996 - IRG/WP 96-10148
Lower termites harbor in their guts populations of microorganisms known to be indispensable for their survival, being responsible, at least partially, for the digestion of cellulose, the main item of termites'diet. The Reticulitermes species in particular harbor in their hindguts some unique intestinal fauna, for instance protozoa belonging to the genera Pyrsonympha, Dinenympha and Trycho...
L Nunes, D J Dickinson


Effects of steaming heat treatment of wood on the stimulation of termite feeding
1997 - IRG/WP 97-10212
At the 26th IRG conference, we reported that steamed Japanese larch heartwood samples were suffered a serious attack by subterranean termite, Coptotermes formosanus both in choice and no-choice feeding tests. This is possibly caused by the yield of termites stimulants in the wood samples resulting from the steaming process. Since the steaming heat treatment has often been applied to other several ...
S Doi, Y Kurimoto, M Takahashi, T Yoshimura


Accidental mold/termite testing of high density fiberboard (HDF) treated with borates and N’N-naphthaloylhydroxylamine (NHA)
2003 - IRG/WP 03-10462
High density fibreboard (HDF) was made from beech and pine furnish (50:50) and treated with boric acid (0.1-3%), borax (0.1-3%) or N'-N-(1,8-naphthalyl) hydroxylamine (NHA) (0.1-1%) prior to gluing with urea formaldehyde (UF) resin in order to determine resistance to Eastern subterranean termites (Reticulitermes flavipes Kollar), the most economically important termite species in North Am...
S N Kartal, H H Burdsall Jr, F Green III


Accelerated anti-termite laboratory tests, simulation of field conditions and assessment of results for service life
1994 - IRG/WP 94-20034
Termites are one of the most serious biodegrading agents in the tropics. Though some species of termites occur in the warmer temperate regions, only a few species can withstand the rigours of colder regions. Testing of termite resistance of material is done either by field tests or by accelerated laboratory tests. Field tests, though realistic to assess service life, are elaborate, take a long tim...
P K Sen-Sarma


Major insects attacking timber used for building purposes and a practical approach for their control
1990 - IRG/WP 1449
Lignocellulosic materials like wood, bamboos, palmyra palms, reeds, leaves and grasses have been the oldest materials used by human beings. Although with the rapid pace of industrialisation, specially in several western countries, wood began to be replaced with alternative materials like cement, steel etc. yet its use has not vanished even in highly developed countries. Some of the reasons for thi...
V R Sonti, B Chatterjee


Termite durability of sugi (Cryptomeria japonica) heartwood kiln-dried under high-temperature process in relation to wood extractives
2005 - IRG/WP 05-10547
Termite durability of sugi heartwood samples kiln-dried under a high-temperature process were evaluated by using Reticulitermes speratus (Kolbe) as a test termite sp. The n-hexane extractives of these samples were analysed by a GC technique. The less termite durability was shown on the wood samples dried under the high-temperature process, in comparison with that of the air-dried samples. No GC-p...
S Shibutani, E Obataya, K Hanata, S Doi


Temperature studies on two mounds of Coptotermes lacteus (Isoptera)
1986 - IRG/WP 1295
The temperatures within and around two Coptotermes lacteus mounds located in a cleared and shaded forest site in a dry sclerophyll forest in central Gippsland were monitored. Hourly temperature measurements were recorded at each mound over a 24 h period in spring, summer and winter respectively. Regardless of site, Coptotermes lacteus maintained the core temperatures in the nursery area much highe...
D M Ewart, J R J French


Oral toxicity of a slow-acting insecticide Amdro® to the Formosan subterranean termite
1982 - IRG/WP 1162
The use of toxic baits to control the Formosan subterranean termite Coptotermes formosanus Shiraki requires an insecticide that is non-repellent and sufficiently slow acting that poisoned termites leave treated areas before dying. Of the many insecticides screened, only Amdro® exhibited these characteristics. The oral toxicity (LD 50) of Amdro® to Coptotermes formosanus was estimated at 12.33 µ...
N-Y Su, M Tamashiro, J R Yates III


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-40286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Field evaluation of several bait toxicants for subterranean termite control: A preliminary report
1988 - IRG/WP 1376
Since 1983, field studies have been conducted to evaluate the effectiveness of several bait toxicants in reducing subterranean termite populations at the Chipola Experimental Forest in Florida. Tests with fenoxycarb (Ro 13-5223), Ro 16-1295, and Avermectin B1 indicated that fenoxycarb showed the most promise. Large numbers of presoldiers and intercastes have continued to occur in plots treated wit...
S C Jones


Preliminary investigation on the natural durability of Guayule (Parthenium argentatum)-based wood products
2000 - IRG/WP 00-40154
Conventional preservatives used to protect wood from insect and microbial damages are presently of major concern to human health and the environment. Finding alternative and economical preservatives has not been successful. Previous studies have shown that the resinous material extracted from the guayule plant (Parthenium argentatum, Gray) has both insect- and microbial-resistant properties. Unfor...
F S Nakayama, P Chow, D S Bajwa, J A Youngquist, J H Muehl, A M Krzysik


Previous Page | Next Page