IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 291 documents. Displaying 25 entries per page.


Transmission poles with sub-standard retentions protected by Field Liners outperform standard poles in service
1997 - IRG/WP 97-40095
Eucalyptus cloeziana 12m transmission poles were treated with sub-standard creosote retentions of 80kg/m3 and Field Liners were fitted to the poles before they were placed in service at Umbumbulu, Kwazulu Natal. Poles treated with standard creosote retentions of 130kg/m3 but without Field Liners were also placed in service in the same area. Core samples were taken from both groups of poles after 1...
M R Behr, G D Shelver, A A W Baecker


Life cycle analysis of utility poles. A Swiss case study
1995 - IRG/WP 95-50040-05
Use of preservative-treated wood products faces increasing public and political pressure because of environmental concerns regarding the chemicals used to protect the wood. However, critics usually focus only on one single aspect of the whole life cycle of treated wood products, disregarding other environmental effects of timber utilization. To evaluate the ecological consequences of wooden utilit...
T Künniger, K Richter


An Overview of the Status of the Australian Quarantine and Inspection Service Cargo Container Booklet
2009 - IRG/WP 09-20420
Abstract Missing...
H Greaves, J W Creffield


Generic code of good practices for wood protection facilities. Part 1: Wood protection (antisapstain) facilities
1993 - IRG/WP 93-50003
In general, the potential of high toxicity (aquatic and human) of wood protection (antisapstain) chemicals dictates the need to protect the environment and humans from its harmful effects. This document is a compendium of recommendations for the design and operating practices of wood protection facilities. The suggested recommendations focus on achieving the objectives of protecting the environmen...
G Das, V N P Mathur


Waste management of wood products in life cycle assessment
2000 - IRG/WP 00-50154
Within the framework of the European project LIFE SYS WOOD (contractnr. FAIR CT95-7026) TNO has performed a study on the waste management of wood demolition waste for inclusion in Life Cycle Assessment. In LIFE SYS WOOD one of the main aims was to develop a consistent LCA methodology for wood products. LCA case studies have been performed by partners on wood as raw material, glulam contructions, O...
P Esser, P Eggels, A Voss


A summary of work carried out to compare natural and artificial weathering for preconditioning test specimens in testing anti-stain chemicals for wood in service
1976 - IRG/WP 266
Since 1972 work has been in progress within CEN to establish a European standard for the testing of wood preservatives designed to prevent blue-staining of wood in service. The method is based on the Butin test and involves pre-weathering of the samples prior to biological testing. The weathering regime employed is 6 months outside exposure from March to October. This imposes severe limitations on...
D J Dickinson, A F Bravery


Development on Damage Functions of Wood Decay for Building Envelope Design
2005 - IRG/WP 05-10556
For the hygrothermal analyses of building envelope systems for insulation design, we tried a natural decay test of wetted wood specimens without any inoculation of fungi. Three principal experimental types: under steady-state conditions (Experiment A), at a cyclic water dripping under Non-steady conditions (Experiment B) and at a cyclic water dipping under-steady conditions (Experiment C), were ca...
H Suzuki, Y Kitadani, K Suzuki, A Iwamae, H Nagai


Canadian code of good practices - Recommendations for design and operation of wood preservation facilities
1990 - IRG/WP 3582
The rationale and procedures for the development of a set of recommendations for design and operation of wood preservation facilities in Canada are discussed. Multi stake holders involvement in problem identification, problem assessment, state of the art knowledge database, implementation and periodic assessment procedures are important considerations for the successful development of a Code of Go...
V N P Mathur, G Das


A comparative study of CCA type C and B treated poles in service
1993 - IRG/WP 93-50001-05
CCA K33 type B and C treated utility poles, 9 pieces of each treatment type, were analyzed for preservative retention after 11 years in use. Borings were taking 1 m above and 0.3 m below the ground line. Also total amount of copper, chromium and arsenic was determined in soil surrounding the poles. The solubility of these active components in soil was monitored by using different leaching procedur...
A J Nurmi


Resolution from IRG Working Group II Sub-group 4 'Stain in timber in service'
1984 - IRG/WP 2230
Sub-group 4 of IRG Working Group II has completed a series of studies of artificial weathering as an alternative to natural weathering in relation to testing the efficacy of chemicals in preventing blue stain in service. The Sub-group reports that within the limits of the equipments studied and described in its report Document No: IRG/WP/2215 the extent of blue stain varied little as a direct cons...
D J Dickinson


Appearance of PEC-treated poles in service
1985 - IRG/WP 3323
Poles treated with conventional high temperature creosote (HTC) are banned for use in Australia by the major union handling them. Pigment emulsified creosote (PEC) is an acceptable alternative because it provides much dryer and cleaner commodities than does HTC. More than 5000 poles have so far been treated with PEC and many are being installed into service. The brown pigmented PEC 30 B has given ...
H Greaves, C-W Chin, K J McCarthy, J B Watkins


Corrosion of zinc-coated nails used with preservative-treated western red cedar shakes in service
1982 - IRG/WP 3197
The corrosion of metal fasteners used with certain wood species and with preservative-treated woods can be a serious problem. The chemical reactivity of western red cedar (Thuja plicata Donn) extractives to iron and copper is well documented and wood preservative treatments containing copper, chromium, and/or ammonium hydroxide can be expected to similarly attack some metals. This problem is compo...
R S Smith, E L Johnson, A J Cserjesi


Life-cycle assessement of treated wood: A view from the roa
1996 - IRG/WP 96-50078
Life Cycle Assessement (LCA) is being used increasingly as a tool to structure information on the environmental characteristics of material and processes. This paper is based on the experience gained from our LCA studies on treated wood products over the last 4 years. The comprehensive and logical examination af the information available on treated timber provided by LCA has allowed identification...
W Hillier, R J Murphy, D J Dickinson, J N B Bell


Environmental risk assessment of treated timber in service: The Environment Focus Group approach
2000 - IRG/WP 00-50162
In the context of the Biocidal Products Directive (98/8/EC), and of the OECD work on wood preservatives, the Environment Focus Group (EFG), comprising 8 institutes and the European Wood Preservative Manufacturers Group, has been working on the environmental risk assessment of treated timber in service. A literature review of emissions from treated timber has revealed that very little existing data...
G Deroubaix, G Labat, I Le Bayon, S Legay, P Marchal, C Yrieix, E Melcher, R-D Peek, S De Geyter, J Van Acker, W J Homan, D J Dickinson, R J Murphy, E D Suttie, A J Nurmi, A-C Ritschkoff, D Rudolph, I Stephan, D Aston, E F Baines, J B Simonin


Comparative life cycle assessment of Swiss railroad sleepers
1998 - IRG/WP 98-50117
The results of an environmental LCA carried out on railway sleepers made of prestressed concrete, sectional steel and creosote impregnated beech as used on main lines of Switzerland's railways are presented. All extractions from and insertions into the environment which were connected with the manufacture, use and disposal of the different types of sleeper were inventoried and assessed, i...
T Künniger, K Richter


Remedial ground-line treatment of CCA poles in service. Results of chemical and microbiological analyses 6 months after treatment
1986 - IRG/WP 3388
CCA-treated poles in service with incipient internal soft rot were remedially treated by inserting borate rods, brushing with a boron/glycol solution and injecting boric acid paste, copper/creosote paste or a commercial product (DFCK paste). The spread of active chemicals in the treated zone as well as the change in microflora have been studied with time. After six months chemicals had spread to m...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Quality of timber impregnated with preservatives of class AB after three years in service
2002 - IRG/WP 02-20241
Quality of impregnated timber is most often expressed by penetration and retention of the preservative used. Relatively less information is available about the performance of the final product, e.g. decks, panels etc. regarding product’s surface checks, deformations and overall appearance. Together with the timber durability, the above mention features are of esthetical importance in the above g...
N Terziev


Solvent extraction of CCA-C from out-of-service wood
1998 - IRG/WP 98-50107
Elimination of CCA from decommissioned wood prior to disposal is a major environmental issue. One approach is to extract CCA from treated wood, then reuse the 'clean' (may contain CCA, but below hazardous level) wood materials for manufacturing wood-based composites. In the present paper, we focus on effective leaching processes, selection of leaching agents and optimum leaching ...
K M F Kazi, P A Cooper


Remedial ground-line treatment of CCA poles in service. A final report after 60 months' testing
1989 - IRG/WP 3534
Remedial treatment of CCA treated utility poles of Pinus sylvestris with incipient decay was carried out in 1983 and the results of chemical and microbiological analyses 6 months after treatment were reported in Document No: IRG/WP/3388 while microbiological studies 12 and 28 months after treatment as well as chemical analyses of poles treated with boron rods or boric acid paste 28 months after tr...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Economical analysis of the chemicals used on remediation copper, chromium and arsenic from out of service CCA-treated utility poles in Turkey
2004 - IRG/WP 04-50217
There are 20.7 million hectare forested area in Turkey. However, the wood products supplies do not meet demand. One of the wooden products is the utility poles. In Turkey, impregnation of utility poles has been started since 1960's and 5 million utility poles have been used until today since then. Although life time of the utility poles may vary depending on climatic conditions, average s...
E D Gezer, D Toksoy, Ü C Yildiz


Premature failure of treated timber in wharfs in Papua New Guinea, attributed to defects in design
1991 - IRG/WP 4158
The performance of timber in wharfs in Papua New Guinea has been monitored for a number of years. Premature failure of wharf structures was found in many cases to be due to defects in design rather than ineffective preservative treatment. Above-water timbers were found to be prone to severe checking followed by decay. Protection for the end grain of pile tops and the limiting of radial checking in...
S M Cragg


Design of Field Trials for Evaluation of Antisapstain Products
2003 - IRG/WP 03-20263
Field trialing is an important phase of antisapstain product development and careful planning is required to ensure trial validity for predicting performance in the industrial situation. Experiences of trialing antisapstain products on lumber over a ten-year period are discussed in this paper. It is not mandatory to source "fresh " wood for trialing and useful information can be generated even...
F W Frazer, N R Edmonds, B J Nairn


Field Liners™ prevent creosote migration from transmission poles to soil during service
1996 - IRG/WP 96-40067
A full scale trial utilised 150 12m Eucalyptus grandis transmission poles treated with standard retentions of creosote according to SABS Method 457. One hundred poles had Field Liners™ applied while 50 did not. The 150 poles were used to complete an electricity transmission line in Southern KwaZulu-Natal. After 18 months service, incremental cores were taken from 15 cm below the ground lines of ...
M R Behr, G D Shelver, A A W Baecker


Wharf-borer a threat to stored archaeological timbers
1992 - IRG/WP 92-1560
Increased interest in marine archaeology has occured in recent years. Stored waterlogged archaeological timbers have been shown to be degraded by physical and microbial agents. In recent years a new threat has been highlighted, namely the wharf-borer Nacerdes melanura (L.). The objective of this paper is to outline studies of the morphology, biology, life-history and carbohydrate digestion by this...
A J Pitman, E B G Jones, A M Jones, M Rule


Black Stain of Western red-cedar by Aureobasidium pullulans and its Relationship with Tropolone Depletion
2005 - IRG/WP 05-10564
Western red-cedar is valued for its natural durability conferred by fungicidal tropolone chemicals. However, weathered surfaces of WRC products are still susceptible to ‘black stain’ caused by fungi such as Aureobasidium pullulans. The effect of weathering on the tropolone content of heartwood was characterized and correlated with the ability of this fungal species to colonize the same weather...
R Chedgy, R Daniels, P I Morris, C Breuil


Previous Page | Next Page