IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 942 documents. Displaying 25 entries per page.


The development of a field testing technique using Coptotermes lacteus mounds in Australia
1985 - IRG/WP 1270
A method to rapidly screen potential bait substrates placed around Coptotermes lacteus mounds is described. A perforated P.V.C. conduit is buried in a shallow trench in a rectangular arrangement around an active mound. Seven P.V.C. holders containing cork baits are inserted vertically into the conduit around the mound. Within three weeks following installation of the baits around five mound coloni...
J R J French, P J Robinson


IRG/COIPM INTERNATIONAL MARINE TEST - To determine the effect of timber substrate on the efectiveness of different preservatives in sea-water: Coding scheme
1976 - IRG/WP 420
It was agreed in Wildhaus on 15 May 1976 that preparations for the test detailed in Document No: IRG/WP/414 should commence immediately, but that initially only two water-borne preservatives should be used - a copper/chrome/arsenic (CCA) and a copper/chrome/boron (CCB) formulation respectively. PRL, England (R Cockcroft) would be responsible for supplying only the reference species treated with th...
Anonymous


Performance of borate-treated lumber in a protected, above-ground field test in Japan
2004 - IRG/WP 04-30344
This document is supplemental to the previous IRG document (Tsunoda et al., 2002). An experiment to simulate the sill plate (dodai) of the Japanese houses was conducted at the termite field test site of the Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. ...
K Tsunoda, A Byrne, P I Morris, J K Grace


Moisture content and other tested values in. Double layer tests of different size in Lithuania and Germany
2004 - IRG/WP 04-20299
The paper presents measurement results of moisture content and the analysis of durability trial of double layer wood in variants of varying size, conducted in Girionys, Kaunas distr., Lithuania and in Hamburg, Germany. In this trial 3 sample sets of varying size, containing 25, 50 and 100 specimens, are used. The aim of this trial is to ascertain an optimal number of test specimens. The dynamics o...
J Saladis, A O Rapp


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
This field experiment was installed five years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name Granitgard™, as a physical barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight ...
J R J French, B M Ahmed


A field trial to assess the potential of antisapstain chemicals for long-term protection of sawn radiata pine
1986 - IRG/WP 3375
Seven chemical formulations were tested as antisapstain treatments for freshly sawn radiata pine sapwood (90x50 mm²). Each formulation was used with and without a water-repellent additive and was sprayed on to 1 m long boards. The boards were then stacked into "mini" packets and stored unprotected from the weather for 6 months. Haipen 50w (at 0.2 or 0.4% active) and NaPCP (1% active) plus 1.5% bo...
J A Drysdale


Microbial ecology of treated Lap-joints exposed at Hilo, Hawaii for 24 months
1997 - IRG/WP 97-20107
This paper is a continuation of previous work reported in IRG/WP 96-20089 by Molnar et al. (1996) in which Lap-joints, made from Southern yellow pine and treated with ACQ, DDAC or propiconazole were sampled over 12 months exposure at Hilo, Hawaii. 18 and 24 month samplings have since taken place and are reported here. TnBTO treated Lap-joints made of scots pine which were exposed later as a standa...
S Molnar, D J Dickinson, R J Murphy


Collaborative soft rot tests: Specific gravity loss resulting from soft rot
1973 - IRG/WP 227
It was proposed at the 5th meeting of Working Group II of the IRG in June 1973 in Lahti, Finland, that the specific gravity (swollen volume basis) of test blocks used in the IRG Collaborative Soft Rot Tests should be determined on all the blocks at the completion of the exposure period. Specific gravity determined on the basis of the oven dry weight and water swollen volume was selected because (1...
C R Levy


Leaching of components from CCF treated timber in ground contact
1998 - IRG/WP 98-50108
In order to investigate the depletion of different CCF-salts during service small stakes (10*10*450mm³) were treated with five water-borne wood preservatives and after fixation brought into ground contact for several years. After failing some of the broken down stakes were used to determine the remaining concentration of relevant ions and their distribution in different segments of the stakes. A...
E Melcher


A simple field apparatus for measuring relative gaff penetration and assessing the effect of additives for improving pole climbability
2000 - IRG/WP 00-20187
A simple apparatus for measuring and comparing the relative "hardness" of utility poles is described. This "slide-hammer" gaff penetration apparatus was designed as a field testing unit to measure the depth of gaff penetration into test poles after application of a uniform and reproducible force to the gaff. The apparatus is simple to use in both the laboratory and field. Data is provided for resu...
A R Zahora


Co-operative tests concerning the influence of solvent and drying method on the toxic limit of wood preservatives against Coniophora cerebella
1972 - IRG/WP 216
In the working group II of the IRG it was agreed that more knowledge was necessary concerning the influence of the solvent on the toxic limit of organic solvent types of wood preservatives against Basidiomycetes. A test program was drawn up and after discussion in the mentioned working group the final program was accepted by the co-operating institutes in 1969. In the test program two fungicides, ...
T Hof


Assessment of the biocontrol potential of a Trichoderma viride isolate in a field trial
1998 - IRG/WP 98-10252
A field trial has been set up near Dundee, to assess the biological control potential of a Trichoderma viride isolate T60. This isolate has been shown in laboratory tests to be particularly effective in protecting wood against certain basidiomycete decay fungi. Wood was treated with T60 spores using vacuum-pressure impregnation in a pilot preservation plant. Scots pine and Sitka spruce stakes wer...
H F Brown, A Bruce


Soft rot - Soil burial - Tests. Influence of the addition of nitrogen compounds to the soil on wood decay by soft rot
1972 - IRG/WP 213
The decay of wood specimens buried in soil is influenced by various factors. Decisive are the water content, the content of organic substances, the pH-value, the content of mineral nutritive salts, nitrogen content, etc. of the soil. These tests were carried out in order to investigate if the decay of wood in the soil will be influenced by additions of various nitrogen-compounds in different conce...
O Wälchli


Leaching tests on CCA-treated wood using inorganic salt solutions
1984 - IRG/WP 3310
Pinus radiata sapwood treated to approximately 10 kg/m³ with Tanalith NCA or Tanalith C-type CCA preservatives was ground to a fine powder and samples were then leached with solutions of calcium chloride, calcium nitrate, magnesium nitrate, or a mixture of potassium di-hydrogen orthophosphate and di-potassium hydrogen orthophosphate, at 0.03M-1.00M solution concentrations. Leached wood samples we...
D V Plackett


Suitability of different termite species for laboratory testing
1982 - IRG/WP 1159
Different termite species were tested in the laboratory to evaluate the effectiveness of insecticides and wood preservatives in wood against termite attack. Determined were the optimum group size and composition, the matrix (vermiculite) volume and its moisture content. Choice feeding tests with fully impregnated wood blocks which are carried out according to a modified EN 117 procedure for Reticu...
U Kny, H Kühne


Examination of power poles by computerized tomography
1980 - IRG/WP 2142
The technique known as computed axial tomography (CAT or CT) has become widely known because of the success it has achieved in medical imaging and diagnostics. It has now been used to give non-destructive crosssectional pictures of a variety of industrial objects, including wooden power poles, with a spatial resolution of about 1 mm (0.04 in.). It is obvious the benefits that would be derived from...
J A Taylor, I L Morgan, H Ellinger


A novel method for evaluating the performance of water repellents
1987 - IRG/WP 2279
Application of water repellent formulations to timber surfaces offers protection from the weather, reducing degrade and movement. A novel test method has been developed to evaluate the comparative efficacy of such formulations when samples are exposed to weather. The method uses sapstain free sapwood of defect free, untreated, seasoned Radiata pine, (Pinus radiata D. Don.) Water Repellency was det...
A R Moffat


Sub-group on Basidiomycete tests: Experimental programme and schedule of participants
1980 - IRG/WP 2145
The objectives of this IRG COLLABORATIVE BASIDIOMYCETE TEST are to compare results and assess reproducibility of a miniaturised wood block toxicity test when undertaken by different workers in different laboratories. The co-operative scientists and institutes are: Dr K Messner from Vienna (Austria); Dr R S Smith from Forintek (Canada); Mr J Hansen from Sadolins (Denmark); Mr B Jensen from Gori (De...
A F Bravery


Decay rates and strength and stiffness loss in foundation beams
1992 - IRG/WP 92-1563
The TNO Centre for Timber Research has executed an extensive research programme into the rate of decay in foundation beams, as a result of lowering of ground water tables. The aim of the research was to develop a method, predicting the decrease in strength and stiffness in beams, due to wood decay during drytime of foundation beams. With the calculated extremes in decay, the damage caused by local...
P Esser, H S Buitenkamp


Information on a project about the conditions of admissibility of wood-protecting agents in connection with environmental protection in Poland
1974 - IRG/WP 57
Wood-protecting agents are compounds acting toxically on fungi and insects. If handled improperly or carelessly, they may exert an action harmful to health and safety of men. This action is concerning: a) workers employed at the production of wood-protecting agents; b) workers employed at the impregnation, or at the transport and handling of impregnated wood; c) inhabitants of buildings with impre...
J Wazny


Resistance of board materials against fungal decay: A comparative experiment on Kolle flask tests method and direct test method
1985 - IRG/WP 2243
Two sets of plywood (Aucoumea klaineana Pierre) 7 and 11 ply, treated by two preservatives, and untreated, were tested by two methods: 1. Kolle flask test method on malt-agar substrate according to the French standard NF B 51.295; 2. A direct test method in non sterile conditions according to DocNo: IRG/WP/2214. The exposure time far both methods was 12 weeks. After exposure, the degree of attack ...
G R Y Déon, L N Trong


Wood preservation in Uruguay
1987 - IRG/WP 3404
The purpose of this paper is a brief description of the current status of wood treatment in Uruguay. The forest resources of the country are summarized, the environment, their economic importance and future potential. The present wood treating facilities are described, together with the chemicals used and the standards generally accepted. Wood treated products used in the Uruguayan market are cite...
G Baillod


Laboratory tests on the residual effects of pyrethroids against termites thirteen years after application
1994 - IRG/WP 94-30056
This paper is in continuation to a series of articles published on the work being developed in Brazil regarding the feasibility of using photostabl synthetic pyrethroids against termites. Tests were carried out to compare the efficacy of five synthetic pyrethroids with the traditional organo-chlorinated pesticide, chlordane. Wooden blocks were impregnated with alcohol-based solutions of the above-...
A M F Oliveira


Biological Control of Bluestain - Log Field Trials in Canada
2002 - IRG/WP 02-10423
In the summer of 2000 we ran two field experiments (in Alberta and British Columbia) to test the feasibility of using an albino bluestain isolate (Cartapip97TM) to protect lodgepole pine logs from being stained by wild-type bluestain fungi. Results showed that Cartapip applied at the recommended concentration significantly reduced the amount of stain found in the Alberta trials. Cartapip applie...
A Uzunovic, D Minchin, A Byrne


Effects of CCA treatment on settlement and growth of barnacles under field conditions
1998 - IRG/WP 98-50116
As part of a field experiment at seven European marine sites evaluating the effects of CCA treatments on non-target marine organisms, panels treated to nominal loadings of 12, 24 and 48 kg/m3 CCA were exposed at marine sites around the coast of Europe. Within two weeks of exposure, a heavy settlement of barnacles took place on the panels exposed intertidally in France. The intensity of settlement ...
S M Cragg, C Brown, R M Albuquerque, R A Eaton, P Goulletquer


Previous Page | Next Page