Effect of preservative treatment on mechanical performance of round and square poles made of small diameter Scots pine
2012 - IRG/WP 12-40612
A growing proportion of harvested Scots pine (Pinus sylvestris L.) timber originates from the first or second commercial thinning stands. There is a need to find economically viable and high quality wood products that can be manufactured from this raw material. Small log volume means not only demands of increased efficiency for material handling in logistics and manufacturing processes, but also c...
V Möttönen, R Stöd, K Heikkilä, H Heräjärvi


An assessment of soft rot in preservative-treated poles in two test sites and two network areas in New South Wales
2013 - IRG/WP 13-10801
This document presents an extended summary of recent investigations into soft rot attack of preservative treated power poles from the re-inspection of samples selected from two field sites and two in-service trials located in New South Wales, Australia. The in-ground sapwood of selected poles was assessed by probing and, after core sampling, by microscopy to determine the severity and extent of s...
W D Gardner, M A Powell, C Kirton


CT scanning of decay in creosoted poles for overhead lines
2013 - IRG/WP 13-30634
Creosote-treated poles have been examined by means of CT scanning in order to investigate the nature of soft spots that have been found more frequently during the last five years in Sweden. CT scanning provides a very good picture of the interior of the poles and decay can easily be detected. It was concluded that the soft spots in most cases were caused by decay which in turn had to do with extre...
C-J Johansson, A Clang, I Johansson, G Berggren


Conclusions and Summary Report on an Environmental Life Cycle Assessment of Utility Poles
2013 - IRG/WP 13-50299
The Treated Wood Council has completed a quantitative evaluation of the environmental impacts associated with the national production, use, and disposition of pentachlorophenol-treated wood, concrete, galvanized steel, and fiber-reinforced composite utility poles using life cycle assessment (LCA) methodologies and following ISO 14044 standards. The results for treated wood poles are significant. ...
AquAeTer, Inc.


An Overview of Western Red Cedar as a Wood Pole Species
2014 - IRG/WP 14-10815
This paper reviews the characteristics of western red cedar, with particular emphasis on its use in utility poles. Western red cedar naturally grows primarily in British Columbia, Alaska, Washington, Oregon, California, Idaho and Montana. Compared to other commercial softwoods it has low density, increased corrosivity, weaker mechanical properties, high dimensional stability, and high natural dura...
M H Freeman, R Stirling


Incidence of soft rot attack on preservative treated Douglas-fir poles: a preliminary survey
2014 - IRG/WP 14-10818
Occurrence of soft rot decay in Douglas-fir poles treated with ammoniacal copper zinc arsenate (ACZA) or pentachlorophenol in oil was studied. Soft rot was less prevalent in poles treated with penta, but some soft rot was found in approximately 20 % of poles examined. Soft rot was more common in poles treated with ACZA, and, when present, was found in almost 20% of the cells examined. The potenti...
P Torres Andrade, J J Morrell


Scanning Transmission X-ray Microscopy as a tool for examining chemical changes in wood cell walls due to enzymatic activity
2014 - IRG/WP 14-20556
As development of techniques for examining enzymatic activity on solid, complex biological materials, is considered to be an important factor in further development of enzyme applications and for understanding the decay of plant materials, this study explores applicability of Scanning Transmission X-ray Microscope (STXM) for determining chemical changes in enzymatically treated samples at the cell...
D Jeremic, R Goacher, R Yan, C Karunakaran, E R Master


CreoSub – New protection technology to substitute creosote in railway sleepers, timber bridges, and utility poles
2014 - IRG/WP 14-30644
Creosote oil is one of the oldest industrially used wood preservatives. Due to its toxic profile, the European Commission has restricted the use of creosote specific applications, but it is highly controversial within the European Commission. Its approval for use after 2018 is very questionable and may depend on derived research results until then, i.e., the viability of alternatives developed to ...
U Hundhausen, K-C Mahnert, A Gellerich, H Militz


Potential for migration of boron from fused boron rods used as internal remedial treatments of utility poles
2014 - IRG/WP 14-50301
The distribution of boron in Douglas-fir utility poles and in the surrounding soil was assessed over a 54 month period following application of fused boron rods. Boron levels in the wood never reached the levels that might be predicted if diffusion were to produce a uniform chemical distribution, nor did levels in the soil suggest that boron was becoming more concentrated. The results suggest th...
M Konkler, C Freitag, C S Love, J J Morrell, J Renfroe


Migration of copper from copper naphthenate treated Douglas-fir poles during storage
2014 - IRG/WP 14-50302
Preservative migration from treated wood products has raised concerns among regulators, especially when the biocides move into surface waters. In most cases, chemical levels are well below the acceptable minimum level, but can become a concern if large quantities of treated wood are stored in one location. One such case would be a location where utility poles are stored for use in emergency repai...
C S Love, C M Freitag, J J Morrell


Development of a new characterization method to analyse Cypermethrin penetration in wood material by immunolabelling
2015 - IRG/WP 15-30674
The preservative efficacy of organic biocides is strongly related to their capacity of penetration and retention within wood tissues. The specific detection of the pyrethroid insecticide cypermethrin is currently obtained after extraction followed by chemical analysis by chromatography techniques. However visualizing the insecticide molecule within the wood structure requires specific probes toget...
S Tapin-Lingua, K Ruel, J-P Joseleau, D Messaoudi, O Fahy, M Jequel, M Petit-Conil


Performance of copper treated poles and posts after three to fifteen years of exposure
2016 - IRG/WP 16-20595
Copper based wood preservatives are one of the most important wood preservatives for heavy-duty applications. Wood treated with copper-based preservatives performs excellent if applied according to preservative specifications. If used improperly premature failures might appear. In order to elucidate properties of copper treated wood in use, utility poles and posts treated with copper-based preserv...
M Humar, N Thaler


Encapsulation of poles to prevent moisture uptake – a laboratory test
2016 - IRG/WP 16-40753
Premature failure of utility poles due to decay in soil contact is the main reason for early removal of utility poles, a measure that implies extra costs for utilities. Remedial treatments and barriers are common methods to prolong the service life of utility poles. The first part of this paper gives an overview of mode of action and commercial application of barrier systems as described in the li...
K-C Mahnert, U Hundhausen


A Case Study of Long-term CCA Preservative Leaching from Treated Hardwood Poles in a Humid Tropical Condition
2016 - IRG/WP 16-50324
Chromated copper arsenate (CCA)-treated Malaysian hardwoods have long been used as utility poles, posts, construction piles and motorway fencing in soil contact exposed to the threats of decay fungi and termites. Despite global concerns citing predominantly temperate conditions of long-term leaching of CCA toxic heavy metals from wood into surrounding soils and groundwater since the 1990’s, the ...
A H H Wong, W S M Chin


Five-year evaluation of a field trial of Eucalyptus grandis poles treated with zinc and boron
2017 - IRG/WP 17-30721
Round Eucalyptus wood treatment in sequential stages with inorganic borates and metal salts (zinc sulfate and boric acid+borax) was studied; the aims were to form an insoluble precipitate of zinc borate inside wood and to reduce treatment costs by performing the first treatment by simple ascent and diffusion of the preservative, at the same time as it was sought to impregnate the heartwood. The se...
C Ibáñez, A Camargo, C Mantero, M Rabinovich


Environmental protection and long term in-service sustainability of preserved wooden poles is secured by non-toxic barrier protection system – History and case studies in South Africa
2018 - IRG/WP 18-50340
Non-toxic flexible sheeting systems have been developed to encapsulate the ground contact regions of preserved wooden poles and prevent their premature failure in South Africa since 1992 but the technology also has a long history of resistance by individuals with vested interests in the built-in redundancies of such poles. The concept has, however, been simultaneously validated by many independent...
A A W Baecker


Protecting Sustainable Wood Infrastructure ̶ Improving the Performance of Poles, Piles, Ties & Timbers with Dual Treatments
2019 - IRG/WP 19-30735
Wood is by far the best structural material in terms of environmental impact, as shown by a number of LCA studies. This environmental impact superiority can be improved if the longevity of the commodity is extended. The main durability concern in large cross-section treated materials is the susceptibility of the heartwood to decay, as it is not typically treatable using traditional methods. This ...
J Lloyd, A Taylor, C Brischke, N Irby, M Manning


Boron dual-treatments for Douglas-fir utility poles: Tracking boron migration over time
2019 - IRG/WP 19-30739
The potential for using boron pressure-treatment prior to over-treatment with conventional, heavy-duty wood preservatives to limit internal decay in-service was investigated in two field tests on Douglas-fir utility poles. Pole sections were pressure-treated with disodium octaborate tetrahydrate (DOT) and then over-treated with either pentachlorophenol or copper naphthenate in oil. Alternatively, ...
J Cappellazzi, M J Konkler, J J Morrell


Chemical Analysis of Southern Pine Pole Stubs Sixty Months Following Treatment with a Methylisothiocyanate-Based Solid Fumigant Stick
2019 - IRG/WP 19-30740
Methylisothiocyanate-based fumigants have been commercially used in the United States for over 35 years to control internal decay in utility poles and other wooden structures with little technological advancement. The most recently commercialized methylisothiocyanate-based fumigant is chemically known as dazomet. Dazomet is a free-flowing powder or granule that decomposes in the presence of mois...
D J Herdman, T Pope, R R Browning


Protection of Venetian pilings from marine borers
2022 - IRG/WP 22-10995
This keynote paper describes piling typology, i.e. Aids to navigation, Mooring and berthing and Pileworks. Furthermore, it describes damages to pilings and public tests on alternative materials and protection. Final remarks: Today, all the pole types admitted by the Memorandum of Understanding can be seen in the lagoon. Plastic poles are common for the mooring of small boats and as stilts in some...
D Tagliapietra


An Update on the Status of Industrial Heavy-Duty Preservatives in Europe
2022 - IRG/WP 22-30762
Creosote has been used for over 150 years for preservation of heavy duty industrial timbers such as railway sleepers, utility poles, and agricultural posts. The regulatory regimes in place today across Europe (eg EU & GB Biocidal Products Regulation (BPR)) require a detailed assessment of the environmental and human health properties of wood preservatives at both the active substance and product l...
S Uphill, H Griffiths, M Giannuzzi, A Hughes


Glued laminated poles - Progress report after 43 years of testing
2023 - IRG/WP 23-20692
In 1979, a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse in Uppsala, in the Simlångsdalen test field in south-western Sweden and in a power lane in Vuollerim in northern Sweden, in order to study their resistance against biological degradation. The test poles were treated in a two-step process. All laminations of Scots pine (Pinus sylvestris) were first...
J Jermer, M Westin, N Terziev


Through-boring to improve the performance of low durability Eucalyptus species for utility poles: 10-year field test results of pole stubs exposed in Southeast Queensland
2023 - IRG/WP 23-40972
An impending shortage of naturally durable hardwood electricity pole timbers in Australia has encouraged investigation of alternatives containing less durable, untreatable heartwood. Through-boring or drilling holes perpendicular to the long axis before treatment, has been used successfully on refractory softwood poles in North America and might have application in Australia. The use of through-bo...
J Norton, L P Francis, J J Morrell


Multi-scale Experimental Study on Self-sustained Smouldering of CCA-treated Timber Poles
2023 - IRG/WP 23-40988
While it is accepted that appropriate treatment with chromated copper arsenate (CCA) will extend the design life of wood markedly, there are concerns regarding the effect of treatment on fire performance. Smouldering combustion in CCA-treated timber infrastructure can self-sustain, destroying the timber elements, as the chromium and copper present in the CCA can act as catalysts of the smouldering...
W Wu, L Yerman, J J Morrell, F Wiesner


Modelling the service life of wood in ground contact – Verification of remotely sensed soil data from the reanalysis dataset ERA5-Land using in-situ measurements at a test site of utility poles in Eastern Norway
2024 - IRG/WP 24-41003
This study compared soil moisture and temperature estimates from the 5th European reanalysis (ERA5-Land) dataset with in-situ measurements to assess the accuracy and applicability of ERA5-Land data for modelling the service life of wood in ground contact. The ERA5-Land soil temperature estimates showed a moderate correlation with the in-situ temperature measurements (Spearman’s ρ of 0.73) and a...
U Hundhausen, P B van Niekerk, B Marais