IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 277 documents. Displaying 25 entries per page.


Environmental consequences of various materials in utility poles - A life cycle analysis
1992 - IRG/WP 92-3726
A model for environmental life cycle analysis, LCA, has been created to compare environmental impact from transmission poles, made alternatively of concrete, steel, aluminium and pine wood treated with CCA type B or creosote. The main pollution sources and energy use are included in the LCA. One pole size, 12 meters long, is presented in the study, a so called "45 kV" pole. Poles of different mate...
M Erlandsson, K Ödeen, M-L Edlund


Dura-Treet II, a water dispersible pentachlorophenol
1980 - IRG/WP 3165
During the past several decades, penta petroleum wood treating has become increasingly popular. Penta is an effective chemical compound against wood organisms causing decay and rot, is safe to handle, also clean and easy to use. In terms of preservative cost, it has been and remains by far the least expensive of the three major preservatives. However, when the cost of petroleum carrier is added, t...
D B Hatcher


Remedial ground-line treatment of CCA poles in service. A progress report after 28 months' testing
1988 - IRG/WP 3481
Remedial treatments of CCA-treated poles in service with incipient soft rot were carried out with boron rods, boron/glycol solution, boric acid paste, copper/creosote paste and a commercial product (DFCK paste) respectively. The micro-flora before remedial treatment and 6 months after as well as the spread of chemicals in the poles were reported in Document No: IRG/WP/3388. In this progress report...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Residual resistance in eucalypt poles according to the degree of sanity
1984 - IRG/WP 2225
A lot of 50 eucalypt poles presenting external deterioration by fungus was taken from service and tested. These poles were classified into five degrees of sanity according to evaluation criteria adopted by the IPT Wood Division. After being classified, they were tested with respect to their bending resistance, in order to gather information about their critical degree of sanity which may define th...
F C Geraldo, S Milano, S G De Sequeira


Influence of different treatment parameters on penetration, retention and bleeding of creosote
2003 - IRG/WP 03-40255
Creosote is an extensively used preservative for transmission poles and sleepers. The purpose of this research was to investigate the treatment parameters necessary to achieve full sapwood penetration and minimum required retention and to avoid bleeding of creosote. It was carried out as a part of the European research project WOODPOLE. Transmission poles of Scots pine (Pinus sylvestris L.) previo...
Ö Bergman


Pole yield of some softwood and hardwood species grown in Bangladesh
1999 - IRG/WP 99-40143
Growth study on 9 timber species planted in Bangladesh soils revealed that 6 species fall under wooden electric pole yield group-A, produce 33% poles within 10 years, another 33% within 15 years and additional 33% within 20 years of rotation. Two species under yield group-B produce 33% poles within 15 years and another 33% within 20 years. One species under yield group-C produce at best 25% poles ...
A K Lahiry


Health and safety regulations on the use of wood preservatives in Switzerland
1980 - IRG/WP 3148
There is not any doubt that the chemical protection of wood (besides the architectional-constructional wood protection) is of utmost importance for the increase of the durability of technically used timber. The toxic properties of wood preservatives make certain legal regulations necessary for the protection of human beings, animals and the environment. Thereby wood preservatives fall under the po...
O Wälchli


Moderate temperature fixation of CCA-C
1989 - IRG/WP 3522
Several Canadian treating plants are using moderate temperature (40-60C°) fixation chambers to reduce drippage and leaching from fresh CCA treated wood. In this study, chromium reduction and surface leaching properties of CCA-C treated red pine (Pinus resinosa) pole sections were monitored during exposure to temperatures of 50-60C° and 90-100% RH conditions. Chromium-VI concentration in the abso...
P A Cooper, Y T Ung


Sterilization to limit pretreatment decay: Internal temperature during kiln drying of Douglas-fir poles
2001 - IRG/WP 01-40206
Sterilization to limit pretreatment decay: Internal temperature during kiln drying of Douglas-fir poles. Fungal colonization of poles following peeling has been the subject of considerable concern among electric utilities. While the presence of fungi does not, in itself constitute a risk, the survival of these fungi through the conventional treating processes could allow them to continue to degrad...
J J Morrell, P G Forsyth, K L Levien


Effects of air-seasoning on fungal colonization and wood strength of Douglas fir poles
1987 - IRG/WP 1315
Air seasoning economically reduces the moisture content of Douglas fir poles before pressure treatment with preservatives. Advanced decay in poles in service has resulted when decay fungi (Basidiomycetes) colonized poles during air-seasoning and survived the treatment process. These problems have led to recommendations to severely limit this practice. To determine the role of these fungi in peeled...
J J Morrell, M E Corden, R D Graham, B L Kropp, P Przybylowicz, S M Smith, C A Sexton


The potential for reuse of treated wood poles removed from service
1993 - IRG/WP 93-50001-18
Poles removed from service in Ontario and Quebec, Canada were characterized by age, wood species, preservative type, residual preservative, dimensions and condition. Based on this charactarization, the potential for reuse as round poles or posts, sawn posts, timbers and lumber, cedar roof shingles and firewood was assessed. A pilot study was conducted to evaluate the recovery and grade of lumber p...
P A Cooper


Wood Preservation in the Federal Republic of Germany
1981 - IRG/WP 3157
The report gives some statistics about the forest products industries in the Federal Republic and a general review of the wood preservation industry. The trend in the use of wooden railway sleepers is decreasing, as is the use of poles. The sale of other pre-treated timber, mainly fence posts, palisades and domestic fences, is however slightly increasing. Apart from the use of pressure treatments ...
R Cockcroft, H Willeitner


Arbeitsverfahren zum Herstellen und mikroskopischen Auswerten von Dünnschnitten aus Holz-Bohrkernen. [Working method for producing and evaluating microscopically thin cuts of bore samples]
1980 - IRG/WP 2133
Bore samples are important specimens; e.g. they are in use to investigate poles in service. On the basis of known methods of microtomy a technique is described which permits the production of longitudinal cuts from bore samples. For this purpose, the bore sample is glued onto a mounting; the surface of cut is coated with a polystyrene solution. The cut thus consolidated can be stained, drained, an...
S Cymorek


Studies on the determination of the durability of wooden poles and fence posts
1982 - IRG/WP 3195
This study was carried out by the Forestry Research Institute. 5 Turkish main tree species, Oak (Quercus), pine (Pinus sylvestris), beech (Fagus orientalis) and Fir (Abies bornmülleriana) wooden poles and fence posts, were treated with Tanalith-U and creosote applying pressure process. Tanalith-U was applied by full-cell process and creosote was applied by empty cell process. Treated and untreate...
R Ilhan, O Taskin, A P Erten


The new method of detecting decay in poles
1984 - IRG/WP 2229
In 1982 the Swedish Telecoms Administration in corporation with the Swedish Dog Training Centre started to investigate the possibility of using dogs for detecting decay in poles. At present two German Sheppheards and two Labrador Retrievers are in operation and the results have up to now well fulfilled our expectations. The following results have been obtained: 1.) The dogs can with high reliabili...
A Ammer, B Svedberg


Chemical Analysis of Southern Pine Pole Stubs Thirteen Months Following Treatment with Three Methylisothiocyanate Based Commercial Fumigants
2002 - IRG/WP 02-30294
Agricultural fumigants have been commercially used in the United States for over 20 years to control internal decay in utility poles and other wooden structures. Of the four fumigants which are currently used in the remedial treatment of utility poles, three are based on methylisothiocyanate (MITC) as being the principal fungitoxic component. Two of these MITC based fumigants, liquid metham sodi...
R J Ziobro, T C Anderson, D J Herdman, J Guzzetta, T Pope


Assessment of the effects of rentex remedial treatment on some wood pole inhabitant micro-organisms
1994 - IRG/WP 94-30053
The effects of a remedial ground-line treatment using Rentex, a stabilised paste containing a mixture of fluoride and dichromate salts, on the micro-organisms inhabiting a sample of some 160 creosoted, on-line, electricity distribution poles, have been investigated as part of an appraisal of the efficacy of this remedial treatment. Half of the poles were treated and the other half used as controls...
D C R Sinclair, G M Smith, A Bruce, H J Staines


The influence of drilling patterns on the distribution of toxicants from Polesaver Rods in hardwood poles
1994 - IRG/WP 94-30051
Polesaver Rods are solid rods of wood preservative that are used as a groundline maintenance treatment to control biodeterioration in hardwood transmission poles in Australia. The rods are inserted in holes that are drilled in a prescribed manner to distribute the toxicants into the critical groundline region of the poles. To determine the influence of drilling patterns on the distribution of toxi...
W D Gardner, C N McEvoy


Study of modulus of rupture, circumference taper, sapwood thickness and CCA treatment of Norwegian origin Pinus sylvestris poles
1994 - IRG/WP 94-20054
Nondestructive strength testing with Pilodyn (6J) of Norwegian Pinus sylvestris poles revealed effective modulus of rupture (MOR) of 54.39 N/mm² at wet conditions after CCA-C treatment and circumference measurement revealed circumference taper of 0.021 m/n. Sapwood thickness or penetration of CCA-C study revealed that 77% poles were with sapwood thickness equivalent to 39.6% of radius of poles an...
A K Lahiry, S Begum, G N M Ilias, M A B Fakir, R U Hafiz


Field study: Wood degradation pattern in buildings and utility poles in tropical climates of Nigeria
1992 - IRG/WP 92-1521
The paper is the result of five years field study of wood degradation patterns in three ecological forest zones (Guinea Savannah, Tropical rain forest and mangrove forest zones, respectively). It involved 800 residential buildings and 700 electric overhead transmission poles. The methodology used was a modified Eslyn (6) test. A high rate of Ascomycetes and Basidiomycetes attack especially on the ...
E O Onuorah


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Wood preservation requirements in Queensland, Australia
1983 - IRG/WP 3227
In Queensland the preservative treatment and utilization of timber must comply with the Timber Users' Protection Act. Preservative retention levels and penetration patterns must be complied with. Analytical zones are specified for removing samples for chemical analysis of preservative retention. The required retention levels have been expressed as percent weight of oven dry wood weight. T...
L E Leightley, M J Kennedy


Glued laminated poles - Progress report after 18 years' testing
1998 - IRG/WP 98-20140
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line in Vuollerim in northern Sweden in order to study their resistance against biological degradation. The tests have shown that the best performance will be obtained if each laminate is first treated with a water-bo...
Ö Bergman, J Jermer


Glue laminated poles - Progress report after 12 years' testing
1992 - IRG/WP 92-3685
In 1979 a number of glued laminated poles treated with CCA and creosote were placed in a greenhouse at Uppsala, at the Simlångsdalen test field in southern Sweden and under a power line just south of the Arctic circle in order to study their resistance against biological degradation. The tests have shown that the comparatively best performance will be obtained if each laminate is first treated wi...
J Jermer, Ö Bergman


Borates as wood preserving compounds: The status of research in the United States
1989 - IRG/WP 3542
This paper describes the extensive, on-going cooperative research effort among government and university research laboratories and industry to fully evaluate the potential for borates as wood preservatives in the United States. Research is discussed in terms of laboratory evaluations, field testing and mill trials, pilot plant pressure treatment studies, and remedial treatments. Future research pl...
H M Barnes, T L Amburgey, L H Williams, J J Morrell


Previous Page | Next Page