IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 796 documents. Displaying 25 entries per page.


Wood Preservation in Belgium
1981 - IRG/WP 3170
The report reviews wood preservation activities in Belgium and notes the number of authorized treatment depots has doubled during the past five years. It lists the timbers that are allowed to be used for joinery and constructional building purposes and the preservatives and treatments with which these timbers may be protected. In Belgium not only have the wood preservative product and its treatmen...
M Stevens, R Cockcroft


The efficacy of preservatives into the glue-line of plywood
1993 - IRG/WP 93-30002
This research is anti-termite/decay preservatives mixed with resin to produce the plywood. Thereafter, anti-decay/termite plywood were produced by the ordinary methods. To produce suitable plywood in the utilization and certified performance, the preservatives should be 0.3 to 0.4 kg/m³ of Chlorpyrifos; 0.88 and 1.10 kg/m³ of mix preservatives of Chlorpyrifos + IF-1000. Laboratories decay test (...
S Fushiki, T Saito, Y Katuzawa, Y Imamura, S Yusuf, B Subiyanto


Comparison of Temporal Changes in Metal Leaching and Aquatic Toxicity from Wood Treated with CCA and Alternative Preservatives
2005 - IRG/WP 05-50236
This study compares the temporal variation of chemical leaching and aquatic toxicity of wood treated with chromated copper arsenate (CCA) and other copper-based wood preservatives (alkaline copper quaternary (ACQ), copper boron azole (CBA), copper citrate (CC) and copper dimethyldithiocarbamate (CDDC)). Treated wood blocks were leached for 21 days and the leachate collected was analyzed for prese...
B Dubey, T G Townsend, G Bitton, H M Solo-Gabriele


Industrial fixation of chromium based wood preservatives
1990 - IRG/WP 3630
Fixation is an abstract and non-defined process. Nevertheless it is a specified requirement in most impregnation standards. The impregnation industry is facing increased pressure to deliver fixed products and to increase the safety of the handling of impregnated products. Industrial fixation of impregnated wood can be obtained by using different methods. The purpose of the process is to transform ...
T Christensen


International standards - can we make them simple? Stage 2: Reflection arising from the discussion at IRG 27
1996 - IRG/WP 96-20103
For the purpose of the ISO FAST TRACK project on preventive wood protection and durability, one shall refer to the 3 following stages: Hazards: (for wood in service), a review of biological agencies defining the scope; Exposure: a review of local, geographical parameters influencing the virulence of biological agencies towards wood in service (i.e climate indexes); Risks: as a combination of ha...
G Ozanne


Environmental risk assessment of wood preservatives in the Netherlands
2001 - IRG/WP 01-50166-10
Before biocides can be introduced to the Dutch market, they have to be authorised under the Pesticides Act (1962). The criteria for authorisation of biocides have been laid down in the Dutch Decree on Environmental Requirements for the Authorisation of Pesticides Used in Fields Other than Agriculture. In 1998, the EU Biocides Directive (98/9/EC) entered into force, and it was implemented in May 20...
E Smit, P van der Zandt, J Appelman


Stake test with ammoniacal copper in combination with different agents started in 1962
1997 - IRG/WP 97-30130
In 1962 a stake test was started with ammoniacal copper in combination with chromium, arsenic, pentachlorophenol, boron, salicylic acid, benzoic acid, sorbic acid, pyridine and tannin. Different concentrations of the copper component were used as well as the added agents. For each concentration and test site, ten stakes of Pinus sylvestris L. sapwood were treated. The stakes were set out at two te...
B Häger, Ö Bergman


Restrictions on the use of chlorosilanes as potential wood preservatives
1985 - IRG/WP 3345
The biological protection of wood by chemical modification with different types of chlorosilanes has been investigated. The impregnation of wood has been carried out by means of liquid phase and vapor phase treatments using pure silane and silane-solvent systems. The biological efficacy against wood rotting fungi, molds and staining fungi was determined in a number of screening trials, subsequentl...
M Stevens


The effects of preservative treatment and exposure to wood degrading fungi on fiber reinforced polymer (FRP) materials used for structural wood reinforcement
2001 - IRG/WP 01-40204
Glass fiber reinforced phenolic (GFRP) composite materials are becoming increasingly accepted for use in the construction industry because they combine advantages of both wood and advanced polymeric materials. Addition of only 1-3% FRP in the tension zone, for example, can typically improve the strength of the hybrid system by 200%. As more applications are found for wood/FRP hybrids, (e.g. lamina...
C Tascioglu, B Goodell


Fungitoxic effect of the quaternary ammonium compounds wood preservatives against the Ascomycetes and Deuteromycetes
1997 - IRG/WP 97-30138
Results of investigation on fungitoxic value of the three formulations of wood preservatives based on the quaternary ammonium compounds (lauryldimethylbenzylammonium chloride, lauryldimethylbenzylammonium bromide, alkylbenzyldimethylammonium chloride) in relation to the surface wood colouring (moulds) and soft-rot fungi have been presented. The agar-plate (screening) and agar-wood plate for mouldi...
J Wazny, P Rudniewski


Wood preservation in Brazil
1978 - IRG/WP 3126
Wood preservation was stablished in Brazil by 1902 in order to provide treated sleepers for railways, since there was a shortage of durable hardwoods in area served by railways. The growing need of sleepers and poles together with the availability of Eucalyptus spp. contributed for the development of wood preservation. Many wood preservation plants started to be stablished in 1957, and in 1977 the...
M S Cavalcante


The detection of organic solvent preservatives in wood by thin-layer chromatography
1975 - IRG/WP 357
A simple and rapid method for the detection of common organic solvent wood preservative materials is described. The method uses thin-layer chromatography after leaching of the preservative from sections of timber with chloroform. RF values and the sensitivity of the method are discussed and a routine procedure for identification of the organic and organometallic preservatives is proposed. Methods ...
B G Henshaw, J W W Morgan, N Williams


Comments on leaching in view of accelerated testing
1977 - IRG/WP 294
We developed an accelerated test for leaching at elevated temperatures (75-85°C). This test was used for the examination of 11 preservative formulations containing Cu, Zn and As. The data obtained from these experiments were compared with data on some formulations tested by ASTM standard leaching test. The method consists in making a large surface to volume ratio of wood from a treated block by c...
J Rak


Wood preservatives. The state of French legislation (June 1977)
1977 - IRG/WP 3106
There does not exist any special legislation for preservatives but general laws may intervene at three levels:-Manufacture -Transport -Selling. In every case, it is based on a poisonous substances classification, an official classification provided by a para-governmental organisation which includes toxicologists. This legislation may refer to other texts: categories of danger for transport (the Eu...
M Romeis, P Guéneau


Development of software to automate the quantification of checking occurring in preservative treated wood exposed to weathering
2001 - IRG/WP 01-20228
Surface checking often disfigures the appearance of wood treated with water-borne preservatives and treatments designed to reduce such checking have been receiving increasing attention. Progress in this area has however been slowed by the lack of a method of rapidly and accurately quantifying checking at treated wood surfaces. A software package has therefore been developed which identifies, measu...
A G Christy, P D Evans


Evaluating the performance of wood preservatives against fungi
1974 - IRG/WP 247
A compilation is made of results published by various workers for agar/block laboratory tests of the effectiveness of wood preservatives against 11 species of wood destroying Basidiomycetes and one species of soft rot fungus. Preservatives include creosote, boron, metal/arsenic mixtures, metallic naphthenates, chlorinated naphthalene, chlorinated phenols and tri-n-butyl tin oxide. The results are ...
R Cockcroft


CCFZ, a new type of water-borne wood preservative for vacuum pressure impregnation
1991 - IRG/WP 3643
By combination of CCF-Salt types with zinchexafluorosilicate a remarkable improvement of efficacy is achieved. In the same time the ecotoxicoligical data become more save. As well as the efficacy against wood-destroying organisms (Basidiomycetes, Soft rot and Long horn beetle) the basic data to evaluate the ecotoxicological behaviour of a CCFZ-Salt are described and compared with the properties of...
W Metzner, D Seepe, H-W Wegen


The preventive effectiveness of preservative treatments against wood-rotting fungi. Preliminary results
1992 - IRG/WP 92-2407
The efficacy of a range of preservative treatments in preventing colonisation by decay fungi has been assessed using a method developed at BRE and similar to that adopted by Working Group 9 of European Standards Committee CEN/TC 38. Assessment was made using baits inserted into the test blocks, in holes which had been drilled after treatment to within defined distances of the treated face exposed ...
J K Carey


Methods for the assessment of wood preservative movement in soil
1995 - IRG/WP 95-50040-08
This paper presents preliminary results from a series of experiments constructed to provide laboratory data for the evaluation of the leaching of wood preservatives into and through soil. The experiments included: i) measurement of the adsorption of preservatives by soil; ii) determination of the concentration gradient of preservatives in soil following percolation of preservative solution through...
G E Holland, R J Orsler


Determination of corrosive effect of liquid wood preservatives to metals – First experiences with a National Standard which is in revision
2006 - IRG/WP 06-20321
The development of standards is an essential tool to characterise different kind of materials and products. An important aspect during the development of a new product is to check the corrosion behaviour with other materials. Corrosion can cause several problems like pitting corrosion. Consequently the knowledge concerning the corrosive effect of liquid wood preservatives is important due to the s...
E Melcher


On the use of probit analysis for assessing the toxicity of wood preservatives
1974 - IRG/WP 244
To elucidate the general character of the action of the toxic material on the fungus, it is sufficient to carry out preservative tests using the previously described procedure, but in doing so, it is necessary somewhat to change the number of specimens and their arrangement in jars. Five concentrations of toxic material are tested simultaneously. For the testing of one preservative ten jars should...
D A Belenkov


Comments on soft rot attack in timbers treated with CCA preservatives: A document for discussion
1982 - IRG/WP 1167
This paper is not based on any particular results but rather on several observations of soft-rot during many years of studies, and on a review of the existing literature. The short time available has unfortunately not permitted a detailed review of the literature. Data and knowledge of important facts are lacking for several aspects of soft-rot attack and for reactions occurring in the wood as a r...
T Nilsson


Evaluation of the protective means of some wood preservatives by means of accelerated tests
1973 - IRG/WP 232
In site conditions of the eastern site in the forest-steppe part of the Krasnovarsk region, the relative effectiveness of a series of wood preservatives was obtained by means of field tests. To obtain a more accurate evaluation of the protective qualities of these accelerated tests were carried out in laboratory conditions. In 9 boxes filled with non-sterile soil taken from the site, 72 samples of...
I A Petrenko


Determination of fungitoxic value of preservatives in laboratory wood-block tests. Part 2: Statistical estimation
1989 - IRG/WP 2327
Laboratory modified agar-block tests were made to determine the fungitoxic value of the wood preservative CCA against the test fungus Serpula lacrymans using statistical methods. With the aid of statistical computer programmes based on the least square method. the regression equation was found for the dependence between sample mass loss and preservative retention both in terms of percentage and fo...
J Wazny, J D Thornton, K J Krajewski


Metal plate fasteners in trussed rafters treated with preservatives or flame retardants - corrosion risks
1977 - IRG/WP 3104
In designing roof trusses employing metal plate fasteners it is generally assumed that the roof will remain dry in service. Whilst this is generally true, damp conditions do arise under some circumstances, although it is not possible to quantify the extent of the risk. It is only possible, therefore, to give general recommendations which must be interpreted in the light of local experience of serv...
R A Laidlaw, L C Pinion


Previous Page | Next Page