IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 796 documents. Displaying 25 entries per page.


Supplement to Document No: IRG/WP/56. Health and safety aspects of the use of wood preservatives
1975 - IRG/WP 356
H Willeitner


Wood preservation in France. "Bois plus" chain of quality. Description of the scheme early 1989
1989 - IRG/WP 3519
1989 - description of the French "CTB-BOIS PLUS" homologation scheme
G Ozanne


Point sur la réglementation et contraintes administratives
1990 - IRG/WP 3575
J H Moneger


Exposure trial at tropical marine sites of pyrethroid/creosote mixtures as wood preservatives: Preliminary results
1989 - IRG/WP 4155
Pinus sylvestris sapwood blocks measuring 25 x 25 x 200 mm³, impregnated using a Lowry or Rüping pressure treatment cycle with solutions of permethrin, cypermethrin or deltamethrin in BS144 creosote, have been exposed at marine sites in Australia, Papua New Guinea, the U.K. and Singapore. The effectiveness of these solutions in preventing marine borer attack is being compared with the efficacy o...
S M Cragg


Determination of the preventive efficacy against wood destroying basidiomycetes fungi, EN V 839 - CEN/TC 38 WG 9
1993 - IRG/WP 93-20015
The WG 9 of CEN TC/38 has presented to EC a mycological test to assess efficacy of preservatives applied by surface process. This method is now an experimental standard (EN V 839) which has to be approved by the different european delegations. The following paper is not the standard as it has been proposed but is a presentation of the principle of the method. The experimental standard specifies a ...
D Dirol


Water-based wood preservatives for curative treatement of insect-infested spruce constructions
1998 - IRG/WP 98-30171
On laying down sanitation measures for wooden constructions infested by wood boring insects, we must take into account static risks for the construction - and, thus, for the security of the user - as well as risks for humans and environment due to the chemical preservative compounds of the treated wood. Analyses on many roof constructions made with spruce (Picea abies L.) have revealed that Hylot...
E Graf, P Manser, B Lanz


Assessing the risks from the use of wood preservatives
2001 - IRG/WP 01-50166-07
PPT-Presentation...
C B Welch


Monographic card on Antrodia serialis
1984 - IRG/WP 1145
G Seehan


Test procedure to determine the effect of timber substrate on the effectiveness of different preservatives in sea-wate
1975 - IRG/WP 414
R A Eaton


Wood Preservation in France. A statement of quality control early 1986
1986 - IRG/WP 3389
A statement of quality control in France early 1986 - Summary of new - Standards criteria for preservatives and treated wood - Aptitude of treated wood for use per class of biological hazard...
M Romeis, G Ozanne


Inventory of the use of preservative-treated wood and wood preservatives in Sweden 1900-1997
1999 - IRG/WP 99-50137
The objective of this study was to present an overview of the use of wood preservatives and their active ingredients and industrially preservative-treated wood in Sweden since the beginning of the 20th century. The data presented in the report could for example be used as a basis for different waste management scenarios for preservative-treated wood. Before 1960 railway sleepers and utility poles ...
J Jermer, K Nilsson


Comparative investigations on the influence of wood seasoning, wood properties and temperature on the toxic values of wood preservatives against Hylotrupes egg larvae
1970 - IRG/WP 28
Comparative tests carried out at three institutes indicated the influence of kiln temperature, position of wood specimens in the cross sectional area and test temperature on the toxic values determined in accordance with DIN 52165 with egg larvae of the house longhorn beetle (Hylotrupes bajulus L.). The preservatives applied were boric acid in distilled water and g-benzene-hexachloride dissolved i...
G Becker, T Hof, O Wälchli


What information can we glean from field testing
1995 - IRG/WP 95-20057
To mathematically compare the performance of preservatives in a field test, equations were formulated to describe the relation between log score and time and between rate of decay and retention. By combining these equations, a model was derived for the performance of a number of waterborne preservatives. Some relations between the estimated parameters for different preservatives were noted and the...
P I Morris, S Rae


On site test for indicative determination of leaching of components of preservatives from treated timber. Part 2: New data on CCA-C, CC and CCB treated timber
1994 - IRG/WP 94-50025
The 'on site test' was published at the IRG meeting in Cannes in February 1993 (IRG/WP 93-50001/12). Since this publication many on site tests were performed parallel to so-called shower tests. The correlation between the test results of the on site tests and the shower test has been established more clearly. For chromium the correlation between both tests is indistinctive of pre...
W J Homan


Detoxification of preservatives: Tri-n-butyltin oxide as a biocide
1982 - IRG/WP 1156
T E Dudley-Brendell, D J Dickinson


Surveillance médicale des personnels exposés aux produits de préservation du bois
1990 - IRG/WP 3588
J-C Aubrun


A new ground-contact wide-spectrum organic wood preservative: DNBP
1986 - IRG/WP 3358
A new organic wood preservative, which 25 years field tests have proved to be of efficiency and effectiveness comparable to CCA wood preservatives for ground-contact applications, is presented. Physical and chemical tests, supporting the long term field test results as well as indicating the characteristics of this preservative, are also presented....
W E Conradie, A Pizzi


Factors affecting leaching of preservatives in practice
1978 - IRG/WP 3113
At the 7th Meeting of the IRG in Poland in May 1975, the findings of collaborative laboratory leaching techniques were discussed, and the dangers inherent in using such results to predict the behaviour of preservative-treated components in service were emphasised. In order to improve our understanding of the factors governing leaching of preservatives in practice, and to identify areas where furth...
R Cockcroft, R A Laidlaw


Accelerated ageing of preservatives in treated wood
1988 - IRG/WP 3476
New preservatives are tested in the laboratory and often in field tests before they are used commercially. Some preservatives, however, tested in the laboratory do not show the expected stability when used in service. The differences between laboratory tests and practical use can never be completely eliminated but must be minimized as far as possible by relevant testing methods. Studies of the eff...
M-L Edlund, B Henningsson, B Jensen, C-E Sundman


Recycling of pressure impregnated timber and preservatives - incineration techniques
2001 - IRG/WP 01-50166-19
The object of the recycling research projects is to determine the technical and economical requirements of the recycling of CCA-impregnated wood. In the first recycling of impregnated timber project the amount and location of recyclable treated wood in Finland was determined and the costs of recycling were calculated. An incineration test was also made (1998). The conclusion of the first project i...
T Syrjänen, E Kangas


Regulations of pesticides (including wood preservatives) in the United States
1977 - IRG/WP 397
G B Fahlstrom


Forest products laboratory methodology for monitoring decay in wood exposed above ground
1995 - IRG/WP 95-20074
Research at the Forest Products Laboratory on the durability of wood in service has included a full complement of laboratory and field tests. In this report, we present a review of past and current methods used to evaluate the condition of preservative-treated wood exposed above ground. Current protocols are described for tests on wood packaging, roofing, and dimension lumber....
R C De Groot, T L Highley


Protocols for assessment and approval of wood preservatives in the Nordic countries
1994 - IRG/WP 94-20046
This paper reviews the protocols presently in use in the Nordic countries (Denmark, Finland, Iceland, Norway and Sweden) for assessment and approval of wood preservatives with respect to their biocidal efficacy....
J Jermer, B Henningsson


Fungus cellar and stake tests with tall oil derivatives. Progress Report after 5 years' testing
1987 - IRG/WP 3442
Two derivatives of tall oils have been tested for five years in fungus cellar and stake tests. The samples were relatively quickly attacked on the surface by decay fungi, mainly soft rot, but the decay has progressed very slowly. The performance of the stakes in the tests has so far been equivalent or even better than some CCA preservatives and creosote....
J Jermer, Ö Bergman, T Nilsson


Scientific development for prolonging the service life of timbers by impregnating with creosote or organic solvent type preservatives in which additive has been incorporated
1977 - IRG/WP 382
Chemically impregnated wood has played a prominent part in the Telephone and Electricity Distribution Industry during the past century and there is no doubt that it will play an equally prominent part in the future. The reasons why wood poles and wooden, structures predominate, are that when adequately chemically impregnated with a recognised timber preservative to ensure the expected service life...
P R B D De Bruin


Previous Page | Next Page