IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 6688 documents. Displaying 25 entries per page.


A novel lipid-related compound, (Z)-1,7-nonadecadiene-2,3-dicarboxylic acid, produced by white-rot fungus Ceriporiopsis subvermispora
2001 - IRG/WP 01-10411
Lipid peroxidation is a possible oxidative process of lignin-degradation at a site far from the enzymes by selective white rot fungi. Production and peroxidation of saturated and unsaturated fatty acids by Ceriporiopsis subvermispora strongly suggests involvement of lipid peroxidation in its ligninolytic system. In this paper, a new aliphatic lipid-related fungal metabolite was isolated from wood ...
M Enoki, Y Honda, M Kuwahara, K Messner, T Watanabe


Agenda Plenary 1989
1989 - IRG/WP 5347
IRG Secretariat


Volatile borates in the treatment of wood and wood based panel products against subterranean termites
1995 - IRG/WP 95-30094
Blocks of pine solid wood, oriented strand board and plywood were treated with trimethyl borate by vapour treatment. It was meant to obtain either a full impregnation of the specimens or a shell treatment of the outer three millimetres. The efficacy of the treatments against subterranean termites (Reticulitermes lucifugus) was evaluated using an European Standard method....
L Nunes, D J Dickinson, R J Murphy


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Field Test Results after Nine Years for CCA and ACQ Preservative-treated Wood Fixed in Different Climates
2003 - IRG/WP 03-30303
During assessment of the ground contact stakes in the Norwegian test field, we have frequently found that the first visual rot attack is in the zone of the stakes, where the stakes have been in contact with each other during the fixation. These parts are usually light green, caused by the lack of light during fixation, compared to the rest of the stake surface, which has a darker colour. To inves...
F G Evans


Influence of bark damage on bluestain development in pine logs
1997 - IRG/WP 97-10197
Mechanized harvesting of conifers can lead to extensive bark damage, with the resulting wounds providing suitable entry points for bluestain fungi that are not associated with bark beetle vectors. However, the amount of bluestain colonisation can vary greatly between the different types of wound. To evaluate the effect of wound type seven different types of wounds were artificially created on fres...
A Uzunovic, J F Webber, D J Dickinson


Assessment of the natural durability of four Ghanaian hardwoods against the white-rot fungus Coriolus versicolor and soft-rot using laboratory tests
2003 - IRG/WP 03-10498
The natural durability of two lesser-utilized species (LUS) (Corynanthe pachyceras Welw. (pamprana) and Glyphaea brevis (Sprengel) Monachino) (foto) from three forest districts, and two related primary species (Nauclea diderrichii (de Wild.) Merr. (opepe) and Nesogodornia papaverifera (A. Chev.) R. Capuron.) (danta) from one district in Ghana is assessed against Coriolus versicolor Linnaeus Quelet...
C Antwi-Boasiako, A J Pitman, J R Barnett


Reporting minutes of the Plenary Meeting 2004
2004 - IRG/WP 04-60197
IRG Secretariat


Measurement of VOC emissions from curative treated wood: A new emission test chamber
2001 - IRG/WP 01-50166-13
A poor indoor air quality (IAQ) is now recognized as a potential factor affecting occupants health. There are three basic strategies to improve IAQ: source control, improvement of the ventilation and use of air cleaners. Usually, the most efficient way to improve IAQ is to eliminate the different pollutant sources or to reduce their emissions. In order to precisely measure emissions from building ...
F Maupetit, O Ramalho, C Yrieix


Climate indices at work: Above ground decay L-joint tests (EN 330 and AWPA E9) at two sites 12000 km apart and with Scheffer climate indices of 60-65 and 300-330
1996 - IRG/WP 96-20095
Matched sets of Scots pine sapwood (Pinus sylvestris) L-joints were exposed above ground at two field sites for approximately five years. One site, at Garston, Watford, UK has a climate index between 60 and 65 while the other, close to Hilo, HI, USA has an index between 300 and 330. The joints were treated with a range of organic solvent treatments applied either by three minute dip immersion or b...
A F Preston, K J Archer, D M Roberts, J K Carey, A F Bravery


Non-destructive testing for the detection of defects in poles (letter to members of Sub-group 5 of WG II)
1982 - IRG/WP 2171
IRG Secretariat


A collaborative test to determine the efficacy of polyurethane coatings on wood samples exposed in the marine environment
1984 - IRG/WP 4113
Aims are: a) to determine the effectiveness of elastomeric polyurethane as a protective coating against marine wood boring animals in a range of tropical and tempreate sites; b) to compare the adhesion of polyurthane coatings on different wood species exposed in seawater; c) to record the severity of attack in failed samples and to identify the causal marine organisms....
R A Eaton


Report of the meetings of the Refractory Timbers Sub-group, Rotorua, New Zealand, 15 & 17 May 1990
1990 - IRG/WP 3637
R J Murphy


Reticulitermes (Ins., Isopt.) in Central and Western Europe
1969 - IRG/WP I 5A
Reticulitermes flavipes (Kollar) has established itself in Hamburg and Hallein coming from the east of North America. In France, on the northern boundary of termit occurrence, Reticulitermes santonensis are distinguished from Reticulitermes lucifugus by special activity and resistance. According to comparative investigations with colonies of several Reticulitermes species of different origins rega...
G Becker


Adequate preservative treatment of tropical and subtropical hardwoods for electric anchor logs
1997 - IRG/WP 97-40101
Most available 27 different hardwood species grown in Bangladesh was investigated regarding suitability as CCA-C (chromated copper arsenate type-C) impregnated anchor logs for rural electrification programme. The kiln-drying properties, sapwood thicknesses, CCA treatability grades of sapwood and heartwood, natural durability of heartwood and CCA retainability at specific assay zone separated 27 ha...
A K Lahiry


Effect of Trichoderma harzianum on induction of laccase by Trametes versicolor on ponderosa pine sapwood
1996 - IRG/WP 96-10177
Trichoderma harzianum has long been studied as a possible biocontrol agent against wood degrading fungi, and has provided varying degrees of protection in several European field trials. In laboratory trials, however, this fungus appears to be less active against white rot fungi. This characteristic was studied using a wood wafer sandwich procedure which simultaneously expose ponderosa pine sapwood...
E A Canessa, J J Morrell


Report of Section 1 1996
1996 - IRG/WP 96-10187
IRG Secretariat


Minutes of the meeting of WG IV
1983 - IRG/WP 4104
IRG Secretariat


Evaluation of polystyrene as a protective of wood in sea-water
1986 - IRG/WP 4129
A test is described on the biological protection of wood by treatment with polystyrene. The results, obtained in marine trials, after 18 months, show that the treatment with polystyrene is not all that effective in preventing the attack of marine borers....
A Gambetta


Report of Section 3
1998 - IRG/WP 98-30186
IRG Secretariat


1999 Official Photo
1999 -
IRG Secretariat


Collaborative soft rot tests: Summary of comments on 'Proposals for a standardized soil burial test'
1971 - IRG/WP 202
J G Savory


European standardization for wood preservation
1990 - IRG/WP 2359
G Castan


Health and safety aspects of the use of wood preservatives. Preliminary evaluation of the answers to the IRG-Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 56
This preliminary evaluation of the answers to the IRG/WP-Questionnaire only gives a general survey on those questionnaires, which the author received until June 13, 1974. Details, such as correlations between importance of wood preservation and pollution control, could not be considered due to lack of time. For the same reason it was not possible so far, to evaluate the additional remarks given in...
H Willeitner


Assessment of contamination of soil and water at a CCA treatment plant: A demonstration project
1996 - IRG/WP 96-50067
Soil, sludge, dust and water samples were collected at a copper/chromium/arsenic wood preservation plant. Contamination of soil, sludge, dust and surface water with copper, chromium and arsenic was detected. Levels of contamination were sufficiently high to require remediation. Contamination originated from preservative solution dripping from recently treated wood. Migration of contaminants was vi...
P N Durrant, D C R Sinclair, G M Smith


Previous Page | Next Page