IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 201 documents. Displaying 25 entries per page.


Stability, performance and distribution of propiconazole (R 49362) in acceleratedly aged wood
1991 - IRG/WP 3647
The permanency of propiconazole (R 49362 - WOCOSENÔ technical - Janssen Pharmaceutica) in wood was examined in an 18 month storage test, an evaporative ageing study (EN 73), a volatilization stress experiment, and water-leaching studies (EN 84). The biological efficacy against two brown rot fungi: Coniophora puteana BAM Ebw. 15 and Gloeophyllum trabeum BAM Ebw. 109 was assessed according to the E...
A R Valcke, M Stevens


Preservation of wood composites with zinc borate
1995 - IRG/WP 95-30074
Inorganic borates such as boric acid, borax, disodium octaborate tetrahydrate, and zinc borate can be incorporated into wood composites such as waferboard to impart decay and insect resistance to the final product. Zinc borate is especially well suited for this application due to its efficacy and leach resistance. The paper summarizes the work performed to date in this area. The effects on strengt...
P E Laks, M J Manning


Leaching from field test stakes. Part 2: The distribution in and leaching from different parts of test stakes
1994 - IRG/WP 94-50026
Field test stakes treated with Boliden K33 (copper, chromium and arsenic) and Cuprinol Tryck (CT86) (copper and N-alkylbenzyldimethylammoniumchloride) respectively were exposed in ground contact at two different test fields in Sweden and rejected due to decay after 2 to 28 years. Stakes treated with the same preservatives were also exposed during 7 years above ground. The test stakes have been ana...
F G Evans, B Nossen, M-L Edlund


The influence of drilling patterns on the distribution of toxicants from Polesaver Rods in hardwood poles
1994 - IRG/WP 94-30051
Polesaver Rods are solid rods of wood preservative that are used as a groundline maintenance treatment to control biodeterioration in hardwood transmission poles in Australia. The rods are inserted in holes that are drilled in a prescribed manner to distribute the toxicants into the critical groundline region of the poles. To determine the influence of drilling patterns on the distribution of toxi...
W D Gardner, C N McEvoy


Microdistribution of Copper in Copper-Ethanolamine (Cu-EA) Treated Southern Yellow Pine (Pinus spp.) related to density distribution
2004 - IRG/WP 04-40270
The relationship between copper absorption and density distribution in wood cell walls was investigated in this study. The density distribution on layer level was obtained from two approaches: (1) calculation by using data obtained from literature; (2) microdistribution of carbon and oxygen atoms in the wood cell. The microdistribution of carbon and oxygen in untreated southern yellow pine (Pinus ...
Jinzhen Cao, D P Kamdem, E Pasek


Evaluation of fluid distribution in pressure treated wood in different flow directions
2004 - IRG/WP 04-40281
Among different methods, polymerization technique was chosen to study distribution of fluid through cell types in treated wood. Red maple wood specimens with the size of 2 by 2 by 4 cm (radial, tangential and longitudinal, respectively) were prepared. Styrene monomer was used as the fluid for impregnation; because its physical properties such as surface tension, specific gravity and viscosity fall...
A Omidvar, M H Schneider


Remediation of environmental impacts related to inorganic wood preservative chemicals using in-situ geochemical fixation
2001 - IRG/WP 01-50166-17
Use of the inorganic wood preservative chemical chromated copper arsenate (CCA) has resulted in several documented cases of soil and ground water contamination at wood treatment plants due to spills or releases of the treatment chemical. The most significant impact from releases of CCA to the environment is related to hexavalent chromium contamination of ground water. This is due to the relative s...
R M Thomasser, J V Rouse


The natural history of teredinid molluscs and other marine wood borers in Papua New Guinea
1975 - IRG/WP 410
The teredinids, commonly known as teredos or shipworms, are bivalve molluscs adapted to boring into wood. They are most closely related to the Family Pholadidae, or piddocks, which bore into mud, stone and coral. The teredinids have a relatively small, hemi-spherically shaped shell, the elongated body extending beyond the posterior end of the shell valves. The soft body, protected by the wood and ...
S M Rayner


Inorganic preservative levels in soil under treated wood decks after 8 years natural exposure in Borås, Sweden
2005 - IRG/WP 05-50233
Inorganic preservative components (Cu, Cr and As) were measured to a depth of 150 mm under deck structures made with Scots pine lumber treated with several different wood preservatives and installed in Borås Sweden 8 years ago. Higher contaminant levels were observed mainly under the drip lines and in the top 50 mm of soil. Under CCA treated decks, soil arsenic concentrations increased from ba...
P A Cooper, Y T Ung, M-L Edlund, J Jermer


Northern oak wood and its damages in Iran
1988 - IRG/WP 1377
The Northern oak species of Iran designated Quercus castaneaefolia C.A.M. is distributed widely in caspian littoral. In natural conditions (healthy) has favourable quality and it is used mostly in rural construtions, sleepers, parquets, cross arms for electric and communication poles, it is used also indoor and window construction, benches and finally veneer. This wood in the case of sleepers and ...
D Parsapajouh, P Niloufari


Variation in biological performance of CCA caised by preservative application method
1996 - IRG/WP 96-40072
A series of laboratory studies to investigate the influence of treatment application method on CCA performance in Cosican pine has been completed. Biological decay tests, such as serial exposures, were used to induce decay in wood at preservative retentions of up to 10 kg/m³ CCA salts. Significant differences in performance of the preservative against either brown, white or soft rot decay fungi w...
P R Newman, R J Murphy


Moisture distribution in coated wooden panels. Studies of moisture dynamics by computerized axial tomography
1992 - IRG/WP 92-2413
Certain modern coatings have been held responsible for the rot damages in wood sidings, which have, during the past few years, appeared at an increasing extent in Scandinavia and which have occurred rather soon after the application of the coating. In this study, the moisture excluding effect of different coating systems intended for sidings have been studied with the help of an X-ray technique, c...
J Ekstedt, L O Lindgren, S Grundberg


Three-dimensional modeling of fumigant distribution in wood poles
1993 - IRG/WP 93-30025
The practice of using fumigants to control internal decay has been widely accepted in the United States and has shown to be effect in control internal decay in transmission poles and other large wood timbers. Mathematical models were developed to simulate the chloropicrin movement in utility poles after treatment. The simulation results indicated that treatment of utility poles, using either tradi...
Jing Liu, B Goodell


Distribution of boron from fused borate rods in Douglas-fir transmission poles
1996 - IRG/WP 96-30112
The diffusion of boron from fused borate rods (disodium octaborate tetrachydrate) was monitored over 42 months in CCA-treated Douglas-fir transmission poles. The boric acid equivalent was estimated by the curcumin/salicylic acid color test on increment cores removed from the poles. Moisture content of the poles was quite variable but was always above 20 percent. The percent of increment core lengt...
T L Highley, F Green III, W F Finney


The limitations of legislative information distribution to the UK remedial preservation industry
1995 - IRG/WP 95-50060
The remedial preservation industry in the UK consists of companies that are rarely large enough to fit any of the definitions of small to medium enterprises (SMEs). They are faced with information on a wide range of legislation related to their industry from a bewildering variety of sources. Costs range from free to hundreds of pounds. Recent surveys have shown that a significant proportion of SME...
J M Ibbitson, G S Sawyer


Microdistribution of water-borne preservatives in blue gum treated by full-cell process
1990 - IRG/WP 3617
The present work deals with the study of the microdistribution of copper, chrome and arsenic elements in Eucalyptus globulus Labill. sapwood, treated with a CCA water-borne preservative by full-cell process, with the help of scanning electron microscopy together with energy dispersion X-ray analysis technique. The work shows that the retention of CCA elements is high in vessels and vasicentric par...
D De Sousa Castro Reimão, J M Palacios


A technique for measuring preservative loss or redistribution during leaching
1983 - IRG/WP 2199
Radiata pine sapwood stakes were treated with benzalkonium chloride (AAC) or copper-chrome-arsenate (CCA). After fixation and drying the outer 2 mm and 2-4 mm layers were removed from one radial longitudinal face. The planed face was coated with a waterproof coating and AAC-treated stakes were leached for 6, 12 or 18 weeks; 12 weeks for the CCA-treated stakes. After airdrying three 2 mm layers (0-...
J A Drysdale


Minthea rugicollis (Walk.) (Coleoptera: Lyctidae): A pest of rubberwood
1992 - IRG/WP 92-1570
Rubberwood (Hevea brasiliensis) has grown in prominence as a source of timber in recent years. One of the drawbacks in the utilization of this species is its susceptibility to attack by powder-post beetles belonging to the family Lyctidae. In Malaysia, Minthea rugicollis (Walk) is the, most commonly found species attacking seasoned rubberwood. In this paper, information available thus far on Minth...
F Abood, R W Berry, R J Murphy


Effect of leaching temperature and water acidity on the loss of metal elements from CCA treated timber in aquatic applications. Part 1: Laboratory scale investigation
1995 - IRG/WP 95-50046
In order to investigate the applicability of current prestandard leaching test methods, a series of experiments has been performed on CCA impregnated wood dealing with the influence of pH, temperature and agitation of the surrounding water. The leaching method used in this first part of the investigation is the European prestandard drafted by CEN/TC38/WG11, a short term dynamic leaching test under...
G M F Van Eetvelde, R J Orsler, G E Holland, M Stevens


Fluoride and chromium concentrations in soil adjacent to remedially treated distribution poles
1996 - IRG/WP 96-50066
Soils adjacent to Rentex treated 'on-line' distribution poles were analysed for total fluoride and chromium content for comparison with background values of these elements. Soil samples 6 cm and 25 cm downslope of selected poles were recovered at 1 week, 1 month, 6 and 12 months after treatment. Background soil samples were taken 50 m from the poles at sampling times. Fourteen po...
D C R Sinclair, G M Smith, A Bruce, H J Staines, P Durrant


The micro-distribution of copper/chrome/arsenate in Acer pseudoplatanus and Eucalyptus maculata
1973 - IRG/WP 319
The excellent field performance of copper-chrome-arsenate (CCA) treated timber has been accepted for many years. The preservative loadings used in practice have been based on field trial results, backed by service tests. The performance of treated hardwoods in trials and practice indicated that provided the required loading and penetration could be achieved the performance would be good. Recent un...
D J Dickinson


Leaching tests on CCA-treated wood using inorganic salt solutions
1984 - IRG/WP 3310
Pinus radiata sapwood treated to approximately 10 kg/m³ with Tanalith NCA or Tanalith C-type CCA preservatives was ground to a fine powder and samples were then leached with solutions of calcium chloride, calcium nitrate, magnesium nitrate, or a mixture of potassium di-hydrogen orthophosphate and di-potassium hydrogen orthophosphate, at 0.03M-1.00M solution concentrations. Leached wood samples we...
D V Plackett


Wood preservation in Canada - Regulation and Registration
2001 - IRG/WP 01-50166-02
The Canadian wood preservation industry is at a critical juncture now as a number of initiatives converge on the industry over the next few years. Issues facing the industry include: Re-evaluation of the conventional wood preservative chemicals - inorganic arsenicals, creosote and pentachlorophenol targeted for July 2001. Delayed registration of new actives as a result of re-evaluation activity an...
P A Cooper


Fixation of chromated wood preservatives through technical drying
1990 - IRG/WP 3623
Twin samples of sawn timber of Pinus sylvestris and Picea sp. were treated with copper-chromate-containing wood preservatives and subsequently kiln resp. air dried. After drying, the distribution of preservative and rate of fixation were determined. Drying of freshly treated wood in a condenser type kiln at temperatures of 60°C and 80°C and in a vacuum type kiln at 55°C with a pressure of about...
R-D Peek, H Klipp


Experimental variations in the distribution of CCA preservative in lignin and holocellulose as a function of treating conditions (temperature, concentration, pH, species, and time)
1984 - IRG/WP 3277
The exact distributions between lignin and holocellulose and retentions on wood of copper, chromium and arsenic as a function of various sets of conditions in a 3x3x4x2 factorial experiment in which combinations of three temperatures of treatment, three CCA solution concentrations, four pH's of the initial CCA solution and two timber species, namely Pinus radiata and Eucalyptus grandis, a...
A Pizzi, E Orovan, M Singmin, A Jansen, M C Vogel


Previous Page | Next Page