IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 448 documents. Displaying 25 entries per page.


Field study: Wood degradation pattern in buildings and utility poles in tropical climates of Nigeria
1992 - IRG/WP 92-1521
The paper is the result of five years field study of wood degradation patterns in three ecological forest zones (Guinea Savannah, Tropical rain forest and mangrove forest zones, respectively). It involved 800 residential buildings and 700 electric overhead transmission poles. The methodology used was a modified Eslyn (6) test. A high rate of Ascomycetes and Basidiomycetes attack especially on the ...
E O Onuorah


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


An overview of the economic importance and control of termites in plantation forestry and wood preservation in Peninsular Malaysia
2000 - IRG/WP 00-10382
Both the plantation forestry and wood preservation industries in the tropical and sub-tropical belts of the world, exemplified by the humid equatorial Peninsular Malaysia, regard termites as major destructive pests of standing trees, various timber products and building timber structures. This paper is a compilation of information on these economically important structural pests encountered in bot...
L G Kirton, A H H Wong, Kee Suan Cheok


The use of the Sentricon Termite Colony Elimination System for controlling termites in difficult control sites in Northern California
2000 - IRG/WP 00-10361
Some termite elimination trials in Northern California with the Sentricon Termite Colony Elimination System are presented - one of a large establish-ment, one of a single family residence with a long history of termite damage, one with a single family residence where other chemical treatments had repeatedly failed, and one single family residence in which the termites had not reached the house but...
D H Kistner, R J Sbragia


CCFZ, a new type of water-borne wood preservative for vacuum pressure impregnation
1991 - IRG/WP 3643
By combination of CCF-Salt types with zinchexafluorosilicate a remarkable improvement of efficacy is achieved. In the same time the ecotoxicoligical data become more save. As well as the efficacy against wood-destroying organisms (Basidiomycetes, Soft rot and Long horn beetle) the basic data to evaluate the ecotoxicological behaviour of a CCFZ-Salt are described and compared with the properties of...
W Metzner, D Seepe, H-W Wegen


Variable chlordane residues in soil surrounding houses in Louisiana
1989 - IRG/WP 1404
Eight soil samples from each of 30 houses in greater New Orleans, Louisiana were collected in October, 1986 and analyzed for chlordane residues (ppm). All houses had reportedly been treated in the late 1960's or early 1970's. Chlordane occurred in all samples, and the overall mean (+ SEM) was 870.6 + 96.5 ppm. Residue levels were unaffected by construction type (slab, crawl, craw...
J P La Fage, K S Delaplane


Wood preservation in Iran
1984 - IRG/WP 3270
The report sketches the history of the use of wood in Iran to the establishment of the country's national forest service and gives some figures for Iran's timber needs by the year 2000. Progress in wood preservation has been slow, although items such as railway sleepers and poles have been pressure treated since the first pressure impregnation plant was erected in 1932. Today the...
P Niloufari, R Cockcroft


Wood attacking insects in urban areas in Sao Paulo State - Brazil
1985 - IRG/WP 1267
From 1974 to 1984 the investigators of Wood Division (IPT) inspected, for insect attack, more than 1,500 buildings of several kinds: commercial, residencial and historical buildings, houses and industries. In all cases, IPT was asked to give advices on control and erradication. During that time three papers concerning this problem were published (Cavalcante, 1976; De Lelis, 1978; Zanotto & Can...
P A Zanotto, M D Canedo, D A T Lelis


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


Relationship between the bending strength and the degree of termite attacks on western hemlock by Coptotermes formosanus Shiraki
1990 - IRG/WP 1434
For the examination of the relationship between the bending strength and the degree of termite attacks, Western Hemlock (Tsuga heterophylla Sarg.) was used. Sixty specimens (4.5 x 4.5 x 82 cm³) were attacked by termites at the culture room of Coptotermes formosanus Shiraki. The termites were introduced on the central parts (10 cm) of specimens. In the case of the 2 points loading, the bending mom...
K Suzuki, T Tanaka


A new type of biocide suitable for use in different fields of wood preservation
1993 - IRG/WP 93-30014
A new type of polymeric biocides was developed containing quaternary ammonium and boron ester groups as active structure elements, to overcome the disadvantages of AAC's in wood preservation use and to utilise their good performance due to a broad efficacy against fungi on the other hand. The new biocides called polymeric betains have been tested in laboratory and field tests and especial...
V Barth, H Härtner


Nondestructive assessment of biodegradation in southern pine sapwood exposed to attack by natural populations of decay fungi and subterranean termites
1994 - IRG/WP 94-20042
Field methods for evaluating decay resistance of experimentally treated materials lack a means for quantitative measurement of residual strength. Quantitative relationships between speed of impact-induced waves travelling parallel to the grain and residual compressive strength have been demonstrated in softwood attacked by brown rot-decay fungi, but the effects of termites have not been documented...
R C De Groot, R J Ross, W Nelson


Detection of metabolic gas from termites using ceramic gas sensors
2001 - IRG/WP 01-20222
To evaluate termite attacks in wooden constructions by detecting the metabolic gas from termite colony, the basic performance of three types of ceramic gas sensors (odor-, methane- and hydrogen-selective sensors) was investigated. Four termite groups of different combinations of workers (100 to 1000) and soldiers (10 to 100) of Coptotermes formosanus Shiraki and a small specimen of Japanese red pi...
Y Yanase, Y Fujii, S Okumura, T Maekawa, K Suzuki, T Yoshimura, Y Imamura


The density factor in termite bioassays
1985 - IRG/WP 1252
The initial and final floor surface and food block surface actually used by termites in a small container were converted to estimates of "Living Space" and "Feeding Space" densities for 1/32 to 1½ g groups of termites. The termites were provided with blocks of blotter paper as a food supply. Except where 1½ g groups exhausted the food, the survival of termites was uniformly high (averaging >9...
G R Esenther


Borates as wood preserving compounds: The status of research in the United States
1989 - IRG/WP 3542
This paper describes the extensive, on-going cooperative research effort among government and university research laboratories and industry to fully evaluate the potential for borates as wood preservatives in the United States. Research is discussed in terms of laboratory evaluations, field testing and mill trials, pilot plant pressure treatment studies, and remedial treatments. Future research pl...
H M Barnes, T L Amburgey, L H Williams, J J Morrell


Laboratory method for testing the effectiveness of soil termiticides
1992 - IRG/WP 92-1561
In France, the protection of buildings against termites is based on a chemical treatment of wood, soil and walls. Because of the withdrawal of aldrin from the market, the need of new soil termiticides has appeared. Therefore, a laboratory method derived from Cymorek's method has been developped to assess their effectiveness. Some points are developed like the type of soil, the number of t...
M-M Serment, A-M Pruvost


Laboratory trials of biological control agents against subterranean termites
1991 - IRG/WP 1475
To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiomycetes, were used to challenge the test termite species, Coptotermes formosanus and Reticulitermes speratus. Test fungi were allowed grow and completely in Petri dishes. To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiom...
K Suzuki


The role of toilet paper in studies of desert subterranean termites in Arizona, USA
2000 - IRG/WP 00-10375
Toilet paper rolls were used as a substrate for observing foraging activity of Heterotermes aureus (Snyder) and Gnathamitermes perplexus (Banks) in the Sonoran Desert of Arizona. Foraging was minimal during the winter months, increased in the spring, was high but erratic in the summer, and then was moderate again in the fall. H. aureus foraged within a temperature range of 7.6° to 47°C, G. perpl...
M I Haverty


Methodologies for termiticide testing and standardization
1993 - IRG/WP 93-10043
Standardization of testing methodologies for termiticides has been one of the main topics of discussion for Working Group 1b in recent IRG meetings. While it is agreed that there is a need to provide a standardized testing procedure for industry and regulatory agencies, concerns remain that such a standardized procedure may become an obstacle for developing better testing methods or innovations in...
N-Y Su


The effect of boric acid on the protozoan numbers of the subterranean termite, Reticulitermes lucifugus
1996 - IRG/WP 96-10148
Lower termites harbor in their guts populations of microorganisms known to be indispensable for their survival, being responsible, at least partially, for the digestion of cellulose, the main item of termites'diet. The Reticulitermes species in particular harbor in their hindguts some unique intestinal fauna, for instance protozoa belonging to the genera Pyrsonympha, Dinenympha and Trycho...
L Nunes, D J Dickinson


Inter-laboratory comparison of assessment methods for wood preservatives against subterranean termites: Determination of protection threshold limits for CCA
1999 - IRG/WP 99-10317
In 1996, several institutes conducted laboratory bioassays on the efficacy of unleached Pinus radiata specimens treated with copper-chromium-arsenic (CCA) and copper naphthenate (Cu Naph) at retentions of 0.5, 1.0, 2.0 and 4.0 kg/m3 (total salt for CCA; elemental copper for Cu Naph) against a range of species of subterranean termites (IRG/WP/96-10174). Each participant employed the standard test m...
J W Creffield, M Lenz


Accelerated anti-termite laboratory tests, simulation of field conditions and assessment of results for service life
1994 - IRG/WP 94-20034
Termites are one of the most serious biodegrading agents in the tropics. Though some species of termites occur in the warmer temperate regions, only a few species can withstand the rigours of colder regions. Testing of termite resistance of material is done either by field tests or by accelerated laboratory tests. Field tests, though realistic to assess service life, are elaborate, take a long tim...
P K Sen-Sarma


The wood preservative performance of biocide mixtures containing chlorpyrifos
1994 - IRG/WP 94-30055
Chlorpyrifos (O,O-diethyl[3,5,6trichloro-2-pyridyl]phosphorothioate) was evaluated as a wood preservative insecticide in two long term field tests. In the first project, pine sapwood blocks treated with chlorpyrifos (CPF) were exposed to Coptotermes formosanus using an above-ground test format. CPF is effective in protecting wood from attack by this termite, but its activity appears to decrease wi...
P E Laks


Previous Page | Next Page