IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 622 documents. Displaying 25 entries per page.


Development of decay in untreated, second-growth Douglas-Fir using two exposure techniques in North Queensland
1997 - IRG/WP 97-20110
The results of two exposure techniques for evaluating the development of wood decay in untreated, mill-run lumber from second-growth Douglas-fir containing both sapwood and heartwood are presented. Nominal 50 mm by 100 mm by 2.5 m (2 in. by 4 in. by 8 ft) lumber, No 2 and better, was obtained from a production run in a mill that was processing second growth, Coastal Douglas-fir in western Oregon, ...
J Norton, S Kleinschmidt, R C De Groot, D Crawford


Biological control of blue stain on wood with Pseudomonas cepacia 6253. Laboratory and field test
1989 - IRG/WP 1380
Pseudomonas cepacia strain 6253 was tested as a biological control agent on wood samples under laboratory conditions, as well as in the field. In the laboratory this bacterium controlled blue stain on Pinus radiata, but field test were not totally satisfactory. However, after 2 months of field test, the test samples were 1/3 to 1/2 less stained then the control samples....
R Benko


2nd IRGWP - Questionnaire on the state of pollution control in the field of wood preservation (Introductory letter)
1981 - IRG/WP 3184
H Willeitner


2nd IRGWP - Questionnaire on the state of pollution control in the field of wood preservation
1981 - IRG/WP 3185
H Willeitner


Results of field tests on the natural durability of timber (1932-1975)
1976 - IRG/WP 3105
This paper describes a continuing field stake trial to determine the natural resistance of different species of timber to decay. Data are presented for about 180 timbers, covering over 6000 stakes, and the results are discussed in terms of a natural durability classification....
D W Purslow


Laboratory and field evaluation of Plasmite Reticulation System using bifenthrin as a chemical barrier within wall cavities against subterranean termites.
2005 - IRG/WP 05-20307
Laboratory and field bioassays undertaken to demonstrate Plasmite Reticulation system effectively delivers the termiticide (bifenthrin) within a simulated wall cavity at the required concentration. The chemical assay indicated that the amount of bifenthrin sampled at 5, 10, 15, 20, and 25m along the simulated reticulation system tested (30m) exceeded the manufacturer’s minimum recommendation of ...
J R J French, B M Ahmed, J Thorpe, A Anderson


Development of a method for testing wood preservatives with soft rot fungi
1975 - IRG/WP 250
Although the first publications on experimental soft rot attack date back 20 years ago, so far no test method for evaluating the efficacy of wood preservatives against soft rot attack (Ascomycetes and Fungi Imperfecti) has been generally accepted. The reasons are diverse and the shortcomings and the disadvantages of the methods described are well known and have repeatedly been discussed. The soil ...
M Gersonde, W Kerner-Gang


Effect of felling time related to lunar calendar on the durability of wood and bamboo -Fungal degradation during above ground exposure test for 2 years- (Preliminary report)
2005 - IRG/WP 05-20311
Current study was carried out to know whether the felling time of trees and bamboos based on lunar calendar affects natural durability of felled wood-bamboo or not. Each of one sugi (Cryptomeria japonica) tree of 28 years old and one Moso bamboo (Phyllostachys heterocycla) of around 3 years old was cut 12 times between February and December in 2003. Six sets of sugi tree and bamboo were felled in ...
K Yamamoto, S Uesugi, K Kawakami


Disposal of CCA treated waste wood by combustion - An industrial scale trial
1996 - IRG/WP 96-50068
Totally 272 m³ (62.7 t) of CCA treated utility poles were chipped and incinerated at Jalasjärvi Gasification Plant. In average the whole batch of chips contained 57 kg of elementary copper, 95 kg chromium and 76 kg arsenic. During the 56 h combustion trial the measured arsenic emission to the air was 76 g in total. Copper and chromium emission was less than 1 g. The condensing water from the coo...
A J Nurmi


Isolation and identification of the fungal flora in treated wood
1976 - IRG/WP 144
J F Levy


Recycling of impregnated timber: Part 2: Combustion trial
1999 - IRG/WP 99-50132
Totally 270 m3 (61,3 t) of CCA impregnated wood was chipped and incinerated at the combustion plant of Jalasjärvi. After the normal gas cleaning venture scrubbers were tested. After the trial a metal balance was calculated. Ash was treated at the copper smelter of Outokumpu Harjavalta Metals Oy. Condensate waters were transfered to the Outokumpu's CCA production plant and utilized by the...
L Lindroos


Co-operative field experiment. Performance of preservative-treated hardwoods with particular reference to soft rot: Report of condition of specimens installed in Victoria, Australia
1978 - IRG/WP 3118
J Beesley


Proposals for a field experiment to determine the performance of preservative treated hardwoods with particular reference to soft rot
1975 - IRG/WP 342
It is proposed to treat a series of hardwood stakes in the UK and install them in different sites around the world. The stakes will include 3 reference species common to every site and 2 locally selected species. The hazard of termites should be avoided in order to limit the study to action of micro-organisms....
D J Dickinson


Field and laboratory studies on anti-sapstain preservatives
1982 - IRG/WP 3205
The field tests included 11 different anti-sapstain preservatives and were carried out at different sawmills in southern Sweden. Drying conditions, climate and the local fungus flora were not identical for the different preservatives and comparisons between the preservatives should therefore be made with caution. Results obtained in the field tests are, however, in relatively good agreement with t...
M-L Edlund, B Henningsson


Evaluation of termiticides in field trials
1990 - IRG/WP 3633
Termiticide-treated posts and stakes have been tested at the field test site in Kagoshima, Southern Kyushu, Japan. Various commercial and alternative termiticides have been evaluated annually as TAI (termite attack index), calculated by the equation: TAI = R x P, where R is the mean of attack rating of 0 (sound), 10 (sign of tasting), 30 (slight attack), 50 (moderate attack), 100 (severe attack), ...
M Takahashi, Y Imamura, K Tsunoda, A Adachi, K Nishimoto


Questionnaire concerning assessment of test data from laboratory and field tests
1992 - IRG/WP 92-2418
During the WG II session in Harrogate, UK it was announced, that possibly a working-session on the assessment of test data and correlation between laboratory and field tests might be organised during next year's meeting in Orlando. For that pupose a questionnaire was prepared. The valuable comments and input of Prof. Thomas Nilsson from Sweden is hereby greatly acknowledged....
A R Valcke


Ground contact performance of wood treated by the MSU process
1990 - IRG/WP 3609
Environmental concerns have prompted a renewed interest in accelerated fixation schemes for CCA-treated wood. Results from stake tests of southern pine (Pinus sp.) treated using a conventional Bethell cycle are compared with matched stakes treated using the MSU Process. The effects of adding boric acid to the preservative formulation are also discussed. Differences among test plots are discussed....
H M Barnes, T L Amburgey, R W Landers


Transmission poles with sub-standard retentions protected by Field Liners outperform standard poles in service
1997 - IRG/WP 97-40095
Eucalyptus cloeziana 12m transmission poles were treated with sub-standard creosote retentions of 80kg/m3 and Field Liners were fitted to the poles before they were placed in service at Umbumbulu, Kwazulu Natal. Poles treated with standard creosote retentions of 130kg/m3 but without Field Liners were also placed in service in the same area. Core samples were taken from both groups of poles after 1...
M R Behr, G D Shelver, A A W Baecker


Methods for testing fumigant efficacies against termites
1986 - IRG/WP 1297
Methodologies for testing fumigants against termites are reviewed and factors needed to be taken under consideration for standardization listed. Toxicity should be defined by both direct exposure to the gas and under more practical "barrier" conditions which include test enclosures simulating abiotic surroundings of the termites, i.e. wood, nest material, etc. To observe latent effects, mortality ...
N-Y Su, R H Scheffrahn


A case for adopting a standardised protocol of field and laboratory bioassays to evaluate a potential soil termiticide
2003 - IRG/WP 03-20275
The rationale for adopting a new approach to the field testing of potential soil termiticides is advocated on the grounds that current testing methods are limited to termite bioassays and do not address quantitatively the persistence and bioavailability of soil termiticides to foraging subterranean termites over time and in different soil types. Furthermore, the present testing regimes assume fiel...
J R J French, B M Ahmed


Report of activity of CEN/TC 38: Test Methods for Wood Preservatives
1987 - IRG/WP 2287
G Castan


Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 52
H Willeitner


Utilization of plasma treatments in the field of wood protection
2021 - IRG/WP 21-40912
Plasma treatments have been used for modification of surfaces of wood and wood-based materials for some decades and solutions were developed to apply it for wood protection. This contribution aims to present the background, introduce the available plasma technology, and to give an overview on the typical applications and benefits....
S Dahle, H Militz


Susceptibility of softwood bait stakes to attack by subterranean termites (Isoptera: Rhinotermitidae)
1994 - IRG/WP 94-20037
Sapwood stakes of Australian-grown Araucaria cunninghamii (hoop pine), Pinus elliotii (slash pine), Pinus radiata (radiata pine) and North American-grown Pinus sp. (southern yellow pine) were exposed to subterranean termite attack in an in-ground bioassay. Stakes in bait containers and bare stakes were attacked by Coptotermes acinaciformis and Schedorhinotermes intermedius. Basic susceptibility of...
B C Peters, R T Murray, C J Fitzgerald


Long term performance of CCA preservatives in ground contact
2000 - IRG/WP 00-30223
Copper-chrome-arsenate (CCA) preservatives have been use extensively in New Zealand since the mid-1950s for a wide range of ground contact uses, radiata pine being the main species treated. They have been the subject of a comprehensive field testing programme in up to five sites in New Zealand, the earliest tests being established in 1955. Main factors affecting performance have been formulation t...
M E Hedley, D R Page, B E Patterson


Previous Page | Next Page