IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 484 documents. Displaying 25 entries per page.


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


Response of laboratory groups of Reticulitermes speratus (Kolbe) to different quantities of food
2003 - IRG/WP 03-10489
As part of a project aimed at improving understanding of the foraging biology of Japan’s most widespread wood-destroying termite, different sized groups of Reticulitermes speratus (0.5; 1 and 2 g) from two colonies were kept on 16 or 64 cm3 of sapwood of Cryptomeria japonica for 12 weeks in the laboratory. Patterns of wood consumption, wood consumption rates and survival are discussed....
M Lenz, T Yoshimura, K Tsunoda


Termite standards questionnaire survey
1987 - IRG/WP 1324
J R J French, J P La Fage


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio


Termite researcher questionnaire
1985 - IRG/WP 1274
J P La Fage


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


Wood preservation in the Australian beekeeping industry
1988 - IRG/WP 3473
This paper reports the results of a survey of Australian commercial beekeepers working 200 or more hives in June/July 1985. Nine hundred and forty seven apiarists were asked to participate and to provide information on their wood preservation methods, painting procedures and maintenance of bee boxes. Three hundred and eighty-four apiarists returned completed questionnaires (41%). The main wood pre...
P J Robinson, J R J French


Techniques for field assessment of particulate termite barriers
2000 - IRG/WP 00-10376
Field testing of particulate termite barriers poses problems different from those encountered when testing preservatives or soil termiticides. To ensure an adequate level of challenge, and minimise the risk of a Type II error, the experimental design must promote termite activity and provide a significant, readily detectable, food source which can only be reached by penetrating the test barrier. I...
D M Ewart, E R Rawlinson


Volatile borates in the treatment of wood and wood based panel products against subterranean termites
1995 - IRG/WP 95-30094
Blocks of pine solid wood, oriented strand board and plywood were treated with trimethyl borate by vapour treatment. It was meant to obtain either a full impregnation of the specimens or a shell treatment of the outer three millimetres. The efficacy of the treatments against subterranean termites (Reticulitermes lucifugus) was evaluated using an European Standard method....
L Nunes, D J Dickinson, R J Murphy


Biocides - Efficacy assessment and doses for wood preservatives (product type 8). Local/geographical aspects. Termite control as case study
1999 - IRG/WP 99-20181
Currently, the efficacy of a wood preservative, as biocidal product type 8, is assessed as a ‚critical value' (CV), an efficient dose (retention in wood at a given depth of penetration). CVs are planned to be adapted for exposure to basic target organisms (5 hazard classes) and additional requirements concerning the occurrence of local target organisms in relation with climate, building...
G Ozanne


Implications for comparability of laboratory experiments revealed in studies on the variability in survival and wood consumption between colonies of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae
1983 - IRG/WP 1196
(Summary of paper 1193) Groups of Coptotermes acinaciformis, originating from six colonies, three taken from each of two localities, 1500 km apart, in northern Australia (Townsville, Darwin) were kept at population densities of 0.005, 0.01 and 0.02 g termites/mL. Survival and wood consumption of the groups after 8 weeks followed a similar pattern in the colonies from both collection areas. Groups were least vigorous at the lowest population density; their performance reached a maximum at a population density of 0.01 g/mL. The subsequent decline in vigour was less marked as the highest population density was approached. However, the actual values for survival and wood consumption varied widely between colonies, irrespective of their origin. It is recommended that in all laboratory experiments which use survival and wood consumption as indicators of termite vigour, controls of a favourable as well as an unfavourable food type are included which would serve to monitor the vigour of the termites. Results from termite sources whose vigour falls below a certain threshold value would have to be treated with caution and could not be used in definative data, as e.g. in defining critical retentions of wood preservatives.
M Lenz


Screening potential termiticides: Some thoughts and suggestions on methodology
1988 - IRG/WP 1363
While laboratory bioassays on the efficacy of potential termiticides against subterranean termites continues both to dominate and influence research efforts, suggestions are presented for the need to develop laboratory bioassays that more closely simulate "natural conditions". Not only is this considered desirable, but it will offer more confidence in laboratory and field evaluations and their ana...
J R J French


Preliminary attempts towards the development of a small-scale termite rearing chamber
1982 - IRG/WP 1148
The paper suggests how to prepare a small-scale rearing chamber for termites which might be used for testing the effectiveness of possible termiticides. A technique for breeding the termites is suggested....
M Argoud, J Mocotte, R Sternalsky


WG I Sub-group 4 Termite problems: Documents before the meeting
1983 - IRG/WP 1215
IRG Secretariat


Methane emission by termites, Coptotermes formosanus Shiraki
1995 - IRG/WP 95-10099
Association of methanogenic bacteria only with the smallest-sized symbiotic protozoa Spirotrichonympha leidyi Koidzumi was evidenced by epifluorescence microscopic observations. Workers, which were collected from a laboratory colony and placed in a test container with water supply emitted methane at a relatively constant rate with a peak of 0.76 nmol/termite/hr within the first 72 hrs after the in...
K Tsunoda, W Ohmura, M Tokoro, T Yoshimura


Termite field test results of preservative treated and modified woods in Kumamoto, Japan
2001 - IRG/WP 01-30275
Various preservative treated or modified wood stakes other than CCA, were buried in the soil, maximum for six years in Kumamoto, south west side of Japan. In this area, two main termite species, Coptotermes formosanus and Reticulitermes speratus, are distributed. After two years in field, untreated sapwood of sugi (Cryptomeria japonica) were observed severe attacks by termites, but the preservativ...
K Suzuki


Evaluation by experimentation on site of a new method for termite control
1996 - IRG/WP 96-10173
A new concept of subterranean termite control consists of the installation of toxic baits in or around the infested construction. Dow Elanco has developed a bait system based on Hexaflumuron. This active ingredient is an insect growth regulator with slow acting effect. A lot of trials were conducted in the USA, but none in France until now. We realised on site experiments, in order to estimate the...
A-M Pruvost, M-M Serment, M Jéquel


Termite barriers for new construction
2000 - IRG/WP 00-10341
Subterranean termite protection in Australia has traditionally relied upon the creation of a zone of poisoned soil under and around the structure to prevent termite attack from the ground. The transition away from persistent soil poisons which began with the withdrawal of cyclodienes in 1995 provided market opportunities for innovative barrier systems. The new barrier systems currently being used ...
D M Ewart


Termites in Eastern Canada: An updated review and bibliography
1990 - IRG/WP 1431
This report updates Document No. IRG/WP/1333, issued in 1987. The current distribution of termites in eastern Canada and current termite control practices and controversies are explained, and current research is very briefly summarized. Since 1987, Reticulitermes flavipes (Kollar) (Isoptera: Rhinotermitidae) has been discovered in several more municipalities in the province of Ontario, and in Winn...
J K Grace


The influence of boric acid on respiratory quotients and methane production of subterranean termites
1995 - IRG/WP 95-10136
The toxicity of boron compounds to subterranean termites (Reticulitermes lucifugus) was studied by analysing changes in the levels of oxygen uptake respiratory quotients and methane production. Termites were fed with filter paper treated at different levels of boric acid, the RQ was evaluated by constant volume manometry and the methane production by gas chromatography. Results are discussed in re...
L Nunes, D J Dickinson


Field testing of soil insecticides as termiticides
1986 - IRG/WP 1294
This paper reviews field methods used to evaluate soil insecticides as termiticides by the U.S. Department of Agriculture, Forest Service, Gulfport, Mississippi. Field tests are conducted on a minimum of five "nationwide sites" in the United States to determine the efficacy of chemicals in various soil types and against different termite species. Test results of selected insecticides are presented...
R H Beal


Minutes of WG I, Sub-group 1 Termite problems
1983 - IRG/WP 1219
IRG Secretariat


First draft of a monographic card for Gloeophyllum trabeum (Pers. ex Fr.) Murr
1973 - IRG/WP 113
T Hof


Laboratory and field evaluation of Plasmite Reticulation System using bifenthrin as a chemical barrier within wall cavities against subterranean termites.
2005 - IRG/WP 05-20307
Laboratory and field bioassays undertaken to demonstrate Plasmite Reticulation system effectively delivers the termiticide (bifenthrin) within a simulated wall cavity at the required concentration. The chemical assay indicated that the amount of bifenthrin sampled at 5, 10, 15, 20, and 25m along the simulated reticulation system tested (30m) exceeded the manufacturer’s minimum recommendation of ...
J R J French, B M Ahmed, J Thorpe, A Anderson


Previous Page | Next Page