IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 637 documents. Displaying 25 entries per page.


Accelerated testing for out of ground contact using natural biological preconditioning: Part 2
1997 - IRG/WP 97-20108
Small blocks of scots pine sapwood were treated, buried in vermiculite and exposed to natural microbial colonisation during outdoor exposure prior to laboratory decay testing. An EN 84-type leach trial was carried out on unexposed samples. Periodic microbial isolations, moisture content, permeability and weight loss tests were also conducted. The experiment ran for 12 months. The colonisation of t...
S Molnar, D J Dickinson, R J Murphy


Depletion of preservatives from treated wood: Results from laboratory, fungus cellar and field test
1993 - IRG/WP 93-50001-07
This paper compares results of preservative component losses using a range of test procedures with several different water-borne preservatives. The data shows that laboratory leaching tests are in some cases comparable to, but in other cases significantly underestimate preservative component losses when compared with field or fungus cellar depletion tests. The results also suggest that preservativ...
L Jin, A F Preston


Leaching of Copper from ACQ treated wood exposed above ground
2004 - IRG/WP 04-50219
The leaching of chemicals of ACQ Type C treated wood exposed above ground for 16 months was studied. Commercially treated Hem-fir boards (Tsuga heterophylla Raf. and Amabilis fir Forb) of 37.5 mm by 87.5 mm were used. The amounts of chemical leached monthly by the rainfall were determined and the leachate was collected and analyzed. Also, the environmental factors influencing the leaching were ...
P A Chung, J N R Ruddick


Efficacy of Avermectin B1 dust and bait formulations in new simulated and accelerated field tests
1985 - IRG/WP 1257
Avermectin B1 on a silica carrier dust was used in dust and bait formulations whose efficacy against Reticulitermes flavipes was assessed in new simulated and accelerated field tests. A 0.5 mg avermectin/mg dust and a bait with 50 ppm avermectin in paper pulp sandwiched between pieces of corrugated boxboard caused nearly complete mortality in bioassays and suppression of foraging in field tests. T...
G R Esenther


The development of a field testing technique using Coptotermes lacteus mounds in Australia
1985 - IRG/WP 1270
A method to rapidly screen potential bait substrates placed around Coptotermes lacteus mounds is described. A perforated P.V.C. conduit is buried in a shallow trench in a rectangular arrangement around an active mound. Seven P.V.C. holders containing cork baits are inserted vertically into the conduit around the mound. Within three weeks following installation of the baits around five mound coloni...
J R J French, P J Robinson


Performance of borate-treated lumber in a protected, above-ground field test in Japan
2004 - IRG/WP 04-30344
This document is supplemental to the previous IRG document (Tsunoda et al., 2002). An experiment to simulate the sill plate (dodai) of the Japanese houses was conducted at the termite field test site of the Wood Research Institute in Kagoshima, Japan where two economically important subterranean termite species [Coptotermes formosanus Shiraki and Reticulitermes speratus (Kolbe)] are established. ...
K Tsunoda, A Byrne, P I Morris, J K Grace


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
This field experiment was installed five years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name Granitgard™, as a physical barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight ...
J R J French, B M Ahmed


The use of lap-joints in natural durability testing: moisture content development during 36 months outside exposure trials
2000 - IRG/WP 00-20217
Lap-joint trials (following European Standard ENV 12037) were set up with 11 different softwood and hardwood species. The main aim was to evaluate the suitability of this test standard (developed for testing wood preservative effectiveness) for natural durability testing. The moisture development has been followed during a 36 months period. In this paper, the outcomes of different moisture content...
H Militz, C J Bloom


A field trial to assess the potential of antisapstain chemicals for long-term protection of sawn radiata pine
1986 - IRG/WP 3375
Seven chemical formulations were tested as antisapstain treatments for freshly sawn radiata pine sapwood (90x50 mm²). Each formulation was used with and without a water-repellent additive and was sprayed on to 1 m long boards. The boards were then stacked into "mini" packets and stored unprotected from the weather for 6 months. Haipen 50w (at 0.2 or 0.4% active) and NaPCP (1% active) plus 1.5% bo...
J A Drysdale


Leaching of components from CCF treated timber in ground contact
1998 - IRG/WP 98-50108
In order to investigate the depletion of different CCF-salts during service small stakes (10*10*450mm³) were treated with five water-borne wood preservatives and after fixation brought into ground contact for several years. After failing some of the broken down stakes were used to determine the remaining concentration of relevant ions and their distribution in different segments of the stakes. A...
E Melcher


A simple field apparatus for measuring relative gaff penetration and assessing the effect of additives for improving pole climbability
2000 - IRG/WP 00-20187
A simple apparatus for measuring and comparing the relative "hardness" of utility poles is described. This "slide-hammer" gaff penetration apparatus was designed as a field testing unit to measure the depth of gaff penetration into test poles after application of a uniform and reproducible force to the gaff. The apparatus is simple to use in both the laboratory and field. Data is provided for resu...
A R Zahora


Assessment of the biocontrol potential of a Trichoderma viride isolate in a field trial
1998 - IRG/WP 98-10252
A field trial has been set up near Dundee, to assess the biological control potential of a Trichoderma viride isolate T60. This isolate has been shown in laboratory tests to be particularly effective in protecting wood against certain basidiomycete decay fungi. Wood was treated with T60 spores using vacuum-pressure impregnation in a pilot preservation plant. Scots pine and Sitka spruce stakes wer...
H F Brown, A Bruce


Examination of power poles by computerized tomography
1980 - IRG/WP 2142
The technique known as computed axial tomography (CAT or CT) has become widely known because of the success it has achieved in medical imaging and diagnostics. It has now been used to give non-destructive crosssectional pictures of a variety of industrial objects, including wooden power poles, with a spatial resolution of about 1 mm (0.04 in.). It is obvious the benefits that would be derived from...
J A Taylor, I L Morgan, H Ellinger


Methods of testing anti-stain chemicals for protecting sawn timber during storage and transport
1976 - IRG/WP 273
No international standard method for testing anti-stain chemicals for protecting fresh sawn timber exists. The methods used can be divided into three types: a) Rapid screening tests for finding chemicals effective against blue-stain and mould fungi. The chemicals are tested in agar medium, in pieces of filter paper or on small pieces of wood using pure cultures. b) Laboratory tests for evaluating ...
T Vihavainen


A novel method for evaluating the performance of water repellents
1987 - IRG/WP 2279
Application of water repellent formulations to timber surfaces offers protection from the weather, reducing degrade and movement. A novel test method has been developed to evaluate the comparative efficacy of such formulations when samples are exposed to weather. The method uses sapstain free sapwood of defect free, untreated, seasoned Radiata pine, (Pinus radiata D. Don.) Water Repellency was det...
A R Moffat


The critical timing of inspections for field testing of natural durability
1994 - IRG/WP 94-20018
An overestimation of performance will almost always result if the condition of a specimen is considered to be attained at the precise time that an inspection is carried out. The time at which the condition is actually attained, referred to in this document as the "Condition time", is best considered to be halfway between two successive inspections. The requirement to obtain data that is relevant t...
J D Thornton


Assessment of untreated Papua New Guinean timbers against subterranean termites. Progress Report 1
1990 - IRG/WP 1436
Eight major commercial timber species (Intsia palembanica, Pometia pinnata, Homalium foetidum, Dracontomelon dao, Calophyllum spp., Eucalyptus deglupta, Nothofagus spp., and Alstonia scholaris) were exposed in ground contact against termites. Five replicates of heartwood stakes of 25x25x250 mm³ of each species were randomly embedded in the soil. Results after 24 months exposure showed that Kwila ...
M Rokova, H C Konabe


Susceptibility of heartwood of three Pinus species to attack by the subterranean termite Coptotermes acinaciformis (Froggatt)
1994 - IRG/WP 94-20026
Heartwood of plantation-grown Pinus elliottii (slash pine), Pinus caribaea (Caribbean pine) and Pinus radiata (radiata pine) was obtained from a range of locations throughout Australia and New Zealand for use in a field bioassey with subterranean termites. Timber stock was analysed for a number of stilbene and flavonoid heartwood extractive components which could contribute to variation in suscept...
M J Kennedy, L L Dixon, B C Peters


Leachability of active ingredients from some CCA treated and creosoted poles in service. A progress report after 10 years testing
1990 - IRG/WP 3627
CCA K33 TYPE B treated or creosoted poles, 10 pieces of each treatment type, have been monitored from the treatment plant to an electricity line, which was build up in Southern Finland in 1978. Preservative retention was determined by taking borings at four different levels: 1.5 m from the top end, 1 m above ground line, ground line and 0.5 m below ground. Determinations were made before setting u...
A J Nurmi


Effects of CCA treatment on settlement and growth of barnacles under field conditions
1998 - IRG/WP 98-50116
As part of a field experiment at seven European marine sites evaluating the effects of CCA treatments on non-target marine organisms, panels treated to nominal loadings of 12, 24 and 48 kg/m3 CCA were exposed at marine sites around the coast of Europe. Within two weeks of exposure, a heavy settlement of barnacles took place on the panels exposed intertidally in France. The intensity of settlement ...
S M Cragg, C Brown, R M Albuquerque, R A Eaton, P Goulletquer


Leaching from field test stakes. Results from two different methods of analysis
1993 - IRG/WP 93-50013
Field test stakes treated with Boliden K33 containing copper, chromium and arsenic exposed at three different fields in Sweden and rejected due to decay, have in two studies been analysed regarding leaching and remaining preservatives. The stakes have been exposed during 20 to 43 years. The density of the stakes and content of copper, chromium and arsenic have been determined in the top part of th...
F G Evans, M-L Edlund


Performance of above ground decay test units treated with a substituted isothiazolone
1989 - IRG/WP 3503
RH 287, a substituted isothiazolone, was evaluated for efficacy against decay fungi in an above ground test in Mississippi. After 45 months of exposure, all test units that were pressure treated with this biocide at levels of 0.026 pcf and higher have no deterioration. In addition, the test units that were dip-treated with a solution concentration of 0.5% also have no deterioration. Compared to pe...
D D Nicholas, J A Wilson, D E Greenley


A field evaluation of chromated fluoride as a remedial treatment for creosoted wooden distribution poles
1989 - IRG/WP 3556
A commercial chromated fluoride formulation was applied by injection process to previously inoculated creosoted wooden distribution pole sections at a field site in Scotland and appraisal of the efficacy of the formulation against Lentinus lepideus was undertaken at two month and fifteen month intervals. Preliminary results suggest a rapid elimination of organisms from colonised areas. The usage o...
B King, A Bruce


Some Experiences with Stake Tests at BAM Test Fields and in the BAM Fungus Cellar Part 1: Comparison of Results of Visual Assessments and Determinations of Static Moduli of Elasticity (MOE)
2005 - IRG/WP 05-20319
With examples of routine in-ground stake tests differences are shown in the performance of wood preservatives at the BAM test fields Lehre and Horstwalde and in the BAM fungus cellar. Signs of attack of micro-organisms were assessed visually according to EN 252. Periodical determinations of static moduli of elasticity (MOE) revealed the influence of the attack on the elastic properties of the wood...
M Grinda, S Göller


Accelerating effects of the field biological attacks in a weather controled soil bed room
1997 - IRG/WP 97-20118
For the purpose of the accelerating the field evaluation of the material service life, a weather controlled soil bed room were designed. The room was controlled 30°C, 75%R.H. In this room, water was sprayed 15 minutes a day. The workers and soldiers of termite, Reticulitermes speratus, can be penetrated. The comparison results of preservative brushing coated treated stakes between field ones and ...
K Suzuki, I Momohara, T Nishimura


Previous Page | Next Page