Your search resulted in 987 documents. Displaying 25 entries per page.
Field evaluation determining the toxic effect and diffusion properties of Impel, Improsol and TBTO-capsules in L-joints (spruce) for pretreatment application
1991 - IRG/WP 3641
Bonded joints (L-joints and T-joints) are especially at risk from water absorption (rain, condensation) over bare, unprotected radial wood surfaces (joggle joints). It is therefore quite certain that lasting protection against fungi attack cannot be guaranteed in the long term if the surface of coating is damaged. Therefore, in a field investigation, using L-joints (spruce) over a total period of ...
R Gründlinger, K Messner, O Janotta
Intraspecific variability in feeding capacity of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae)
1983 - IRG/WP 1175
This paper describes laboratory studies to evaluate the comparative feeding capacity within and between five mound colonies of Coptotermes acinaciformis (Froggatt). Matched specimens of mountain ash, pine and coachwood were exposed to five replicate 10 g groups of termites from each colony source. After an initial 8-week exposure period, all groups were assessed for vitality and continued feeding ...
C D Howick, J W Creffield
Water-Borne Copper Naphthenate: An Emerging Wood Preservative
2002 - IRG/WP 02-30280
Waterborne copper naphthenate (WB Cu-N) was used to treat southern yellow pine (Pinus spp) and red maple (Acer rubrum) stakes. The treated stakes were exposed in test sites located in Florida, Michigan and Mississippi for 3 to 6 years. Copper Chromium Arsenate (CCA),
Ammoniacal Copper Quat (ACQ) and Oil-borne Copper Naphthenate (OB Cu-N) were also used to treat some stakes for comparison. Results...
P Nzokou, D P Kamdem, M H Freeman
A dynamic approach to assess the modulus of elasticity in wood decay testing
1998 - IRG/WP 98-20139
In this study, the changes in elastic behaviour and mass losses of different hardwood and softwood species exposed to decay in a laboratory soil tests were assessed. Wood decay was monitored using different assessment methods, namely: mass loss and changes in elastic behaviours (MOE) determination. Elastic changes were determined by static and dynamic methods, for the latter, acoustic technique wa...
L Machek, H Militz, R Sierra-Alvarez
Blue stain in timber in service. Results of further IRG collaborative tests to compare different artificial weathering systems
1981 - IRG/WP 2146
The previous work described in Document No IRG/WP/286 examined 3 preservatives (1% phenyl mercury succinate - PMS, 5% pentachlorophenol - PCP and 1.5% Preventol A4 - PA4) subjected to 5 different artificial weathering systems (BAM Xenotest, Cuprinol Marr, EMPA Xenotest, Gori Atlas and PRL Marr) and after natural weathering at 5 sites (BAM, Cuprinol, EMPA, Gori and PRL). Results showed good correla...
A F Bravery, D J Dickinson
Laboratory and field trials of novel antisapstain formulations
1997 - IRG/WP 97-30146
This document covers the results of laboratory and field trials of combinations of fungicides formulated using a patented technology (PCT NZ 96/00143). A 3 week laboratory trial that uses radiata pine (Pinus radiata D. Don) branch discs as a substrate was used to determine which combinations possessed a suitable spectrum of fungitoxicity against key sapstain, mould and decay fungi. In particular f...
R N Wakeling, P N Maynard, D R Eden, C M Chittenden, B Carpenter
Performance of different treatments and finishes on wood out of ground contact. Preliminary results
1984 - IRG/WP 2221
Pinus and Eucalyptus L-joints treated with CCA, a water dispersable PCP and untreated ones were painted according to seven different finish's schedules and exposed at two sites in State of Sao Paulo. After ten months of exposure, it was possible to verify that preservative treatment improve the performance of both wood and finish. It was also possible to observe that wood substrate, prese...
S Milano
Implications for comparibility of laboratory experiments revealed in studies on the variability in survival and wood consumption between colonies of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae
1983 - IRG/WP 1193
Groups of Coptotermes acinaciformis originating from six colonies, three taken from each of two localities 1500 km apart in northern Australia (Townsville, Darwin), were kept at population densities of 0.005, 0.011 and 0.02 g termites/mL. Survival and wood consumption of the groups after 8 weeks followed a similar pattern in the colonies from both collection areas. Groups were least vigorous at th...
M Lenz
Subterranean termite attack potential in field test sites: assessment methods and field characterization
2003 - IRG/WP 03-10472
To assess subterranean termite attack potential in the field and seasonal variations, trials were set up in each of two managed silvicultural plantations, of Eucalyptus globulus and Pinus pinaster, respectively. Termite occupancy in lying dead wood was evaluated by an adaptation of the line-intersection method, and attack potential in soil was assessed by a system of stakes inserted into the groun...
T Nobre, L Nunes, L Brinca, D E Bignell
Effect of soil type and moisture content on soft rot testin
1986 - IRG/WP 2270
Several soils of different types were tested at a range of moisture contents for their suitability for use in a soil burial soft rot test. Their effectiveness was assessed by weight loss in CCA treated and untreated beech and birch outerwood. A horticultural loam (John Innes No. 2) was the most appropriare soil in terms of amount of weight loss caused, tolerance to changes in soil moisture content...
S M Gray
Xylophene AS™, the challenge of developing a modern antisapstain formulation for the french market
2000 - IRG/WP 00-30250
In France Sodium Pentachlorophenol (NaPCP) has been used for more than 40 years for the protection of freshly cut and unseasoned lumber. The French sawmill industry requires a protection of 6 months and maximum 10% surface infection by moulds and/or sapstain fungi. However, this active substance did have some serious environmental flaws and no authorisation was granted for a direct contact of NaPC...
E Wozniak, L Cubizolles, N Delourme Fonseca, A R Valcke, J Gors
Collaborative field trial out-of-ground contact
1982 - IRG/WP 2179
At the 12th meeting of the IRG in Sarajevo, Yugoslavia it was decided after considerable discussion that the best way to proceed with the work of the subgroup was to centre it around a co-operative field trial based on the L-joint test detailed in IRG/WP/2157. At the same time it was agreed that interested laboratories would also conduct their own methods, particularly the German planner test and ...
D J Dickinson, A F Bravery, J K Carey
Test methods for wood preservatives against Lyctus: (1) Testing of treated veneer. (2) Testing of glue-line treated plywood. (Laboratory methods)
1977 - IRG/WP 293
Powder-post beetles destroy large quantities of veneer and plywood. Two test procedures are described which can be used to support application-oriented research into veneer and plywood preservatives. These procedures simulate practical conditions on a laboratory scale. Their characteristic feature is that wood species of special susceptibility are used for the tests; the susceptibility of the spec...
S Cymorek
Water-borne DNBP wood preservatives - Preparation and performance
1987 - IRG/WP 3407
Three waterborne wide-spectrum ground-contact DNBP (2-sec-butyl-4,6-dinitrophenol) wood preservative formulations and their performance are presented. Two are double-treatment formulations in which insolubilization and precipitation of the preservative is attained by salt formation or by formation of a water insoluble Cu/NH3/DNBP complex of formula [DNBP]2 [Cu(NH3)2]2 the clarified structure of wh...
W E Conradie, A Pizzi
Surface retentions of PCP, TCMTB and MTC obtained during a field trial of antisapstain formulations
1993 - IRG/WP 93-20002
Formulations containing NaPCP or TCMTB and MTC were included as reference products in a recent field trial of antisapstain formulations in Queensland. Retentions of these actives on the surface of treated sawn Pinus elliottii were monitored by ultrasonic solvent extraction of excised samples and analytical determination by high performance liquid chromatography. Distribution of actives with depth ...
D E Ferlazzo, M D Needham, M J Kennedy
Laboratory termite testing of copper boron tebuconazole
2000 - IRG/WP 00-20192
The American Wood Preservers' Association laboratory choice and no choice termite test (AWPA E1-97) was performed on a formulation of copper azole, which is comprised of copper, boric acid, and tebuconazole. The formulation tested has a ratio of copper:boric acid:tebuconazole of 25:25:1. So as to examine the impact of leaching, the southern yellow pine wafers were treated with and without...
R F Fox, E A Pasek, J Patel
Kerfing reduces checking in ACA-treated western white spruce poles
1988 - IRG/WP 3477
Western white spruce poles, pressure treated with pentachlorophenol and ammoniacal copper arsenate (ACA) were installed in the Westham Island test site. The pentachlorophenol treated poles were unkerfed, while both unkerfed and kerfed ACA poles were placed in test. The checking and kerf width and depth were recorded at the time of installation. After ten years of weathering the checking characteri...
J N R Ruddick
Settlement of fouling organisms on CCA-treated Scots pine in the marine environment
1997 - IRG/WP 97-50094
As part of an EU project to investigate the effects of CCA loading on non-target marine fouling animals, exposure panels of Scots pine treated to 12, 24 and 48 kgm-3 CCA and untreated controls were submerged at seven coastal sites (Portsmouth, UK: Kristineberg, Sweden: La Tremblade (2 sites), France: Ria Formosa, Portugal: Sagres, Portugal: Athens, Greece). Inspections were made at 6 and 12 months...
C J Brown, R A Eaton
Interim balance after 20 months of lap-joint exposure
1999 - IRG/WP 99-20164
The application of natural resins and integrated resin systems to improve the performance of Pinus sylvestris was assessed in a lap-joint test according to DIN V ENV 12037 (1996). Lap-joints of Pinus sapwood were exposed at the test field in Hamburg (Germany) in May 1997. The treated lap-joints were assessed with regard to the performance of the resin treatments out of ground. The exposure of lap-...
M Sailer, A O Rapp, R-D Peek, A J Nurmi, E P J Beckers
Non-destructive detection of the presence and behaviour patterns of wood-destroying insects
1988 - IRG/WP 2302
An apparatus, designed for the automatic recognition of the presence and of specific behaviour patterns of wood-boring insects, is introduced. From a wood sample, a mixture of noise and action induced substratum vibrations is picked up, amplified, filtered and translated into a sequence of computer-readable numbers which are passed to a microcomputer-based signal-pattern-recognition. If an incomin...
M Pallaske
Resistance to decay of particle boards: Presentation of a test method
1986 - IRG/WP 2260
The experimentations were undertaken on particle boards 35 and 50 mm thick. The rot resistance tests were carried out on specimens whose dimensions were 600 x 75 x 35 mm³ for particle boards 35 mm thick and 800 x 75 x 50 mm³ for particle boards 50 mm thick according to a method derived from the one described in the documents IRG/WP/2214 and IRG/WP/2243. Two exposure periods were used: 12 and 16 ...
G R Y Déon, N Trong
Termite resistance of Malaysian and exotic woods with plantation potential: Field evaluation
1998 - IRG/WP 98-10289
An in-ground resistance of selected Malaysian and exotic timbers to attack by a representative aggressive subterranean Coptotermes termite was evaluated as part of an on-going collaborative research between the Forest Research Institute of Malaysia and the University of Hawaii on termite control of building timbers under humid tropical conditions. A test site at FRIM, highly susceptible to the sub...
A H H Wong, J K Grace, L H Kirton
Field evaluation of CCA movement in sap-displaced copper chrome arsenic treated softwood poles
1989 - IRG/WP 3539
Commercial sap-displaced UK grown Scots and Corsican pine, and Sitka and Norway spruce poles were exposed in a field site at Dundee, Scotland and radial distribution profiles of CCA monitored prior to implantation and after subsequent field exposure. Results show that groundline levels of all preservative elements were higher after 1 and 2 years field exposure compared with those recorded prior to...
S D Hainey, G M Smith, A Bruce, P D Evans, B King, H J Staines
Performance of preservative-treated wood not in ground contact
1975 - IRG/WP 254
Experimental sash units of Pinus strobus L. and Pinus resinosa Ait. wood were removed from a test fence at Ottawa, Canada after outdoor exposure of over 20 years. The units were superficially treated, prior to painting, with preservatives containing either copper naphthenate, pentachlorophenol or a combination of zinc naphthenate and pentachlorophenol. Results indicated that all treatments were ef...
J K Shields, J Krzyzewski
Soil termiticides: A review of efficacy data from field tests
1987 - IRG/WP 1323
This paper reports efficacy data from the field evaluation of various soil termiticides by the U.S. Department of Agriculture, Forest Service, Gulfport, Mississippi. These chemicals, which include a number of chlorinated hydrocarbon, organophosphate, pyrethroid, and carbamate insecticides in a range of concentrations, have been in long-term tests at seven field sites. Data are reported for the gro...
J K Mauldin, S C Jones, R H Beal