IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 224 documents. Displaying 25 entries per page.


Termite resistance of twenty-eight Indonesian timbers
1982 - IRG/WP 1150
A comparative study of termite resistance of 28 Indonesian wood species has been conducted using small samples measuring 5 x 10 x 20 mm³. The drywood termite Cryptotermes cynocephallus (Kalotermitidae) and the subterranean termite Coptotermes curvignathus (Rhinotermitidae) were used in the study. A resistance classification was derived on the basis of cluster analysis. The result reveals that Alb...
Nana Supriana, P E Howse


Performance of Borate-treated lumber in a four-year, above-ground termite field test in Hawaii
2001 - IRG/WP 01-30265
We report the fourth year of field study results from a protected above-ground field test in Hawaii simulating the sill plate (dodai) used in conventional Japanese housing construction. Field tests were established in both Hawaii and Japan to examine the efficacy of disodium octaborate tetrahydrate (DOT, 2% and 3% shell and through) wood treatments. In Hawaii, chromated copper arsenate (CCA, 4 kg/...
J K Grace, R J Oshiro, A Byrne, P I Morris, K Tsunoda


Assessment of untreated Papua New Guinea timbers against subterranean termites. Progress report 2
1993 - IRG/WP 93-10040
Eight species of Papua New Guinea wood including Kwila (Intsia palembanica), Taun (Pometia pinnata), Malas (Homalium foetidum), PNG Walnut (Dracontomelon dao), Calophyllum (Calophyllum sp.), Kamarere (Eucalyptus deglupta), PNG Beech (Nothofagus spp.) and White Cheesewood (Alstonia scholaris) were exposed groun contact for their natural durability against subterranean termites. Inspection after 42 ...
M Rokova, H C Konabe


Six-year Report on the Performance of Borate-treated Lumber in an Above-ground Termite Field Test in Hawaii
2004 - IRG/WP 04-30343
We report the fifth and sixth years of field study results from a protected above-ground field test in Hawaii simulating the sill plate (dodai) used in conventional Japanese housing construction. Field tests were established in both Hawaii and Japan to examine the efficacy of disodium octaborate tetrahydrate (DOT, 2% and 3% BAE shell and through) wood treatments. In Hawaii, chromated copper arsen...
J K Grace, A Byrne, P I Morris, K Tsunoda


Remedial wood preservative efficacy of BORA-CARE against the Formosan subterranean termite and eastern subterranean termite (Isoptera: Rhinotermitidae)
1991 - IRG/WP 1504
When a spruce board (3.8 cm x 8.8 cm x 2.4 m) was surface-sprayed with BORA-CARETM solution (containing 23% disodium octaborate tetrahydrate) and stored in an air-conditioned room (24 ± 2°C and 60 ± 5% RH) for eight months, ca. 40% of the wood (measured by the cross section surface proportion) contained borates at the rate of >2,500 ppm BAE (boric acid equivalent). In a choice bioassay, term...
N-Y Su, R H Scheffrahn


Termite field evaluations in hawaii: A brief review of methods and issues
1995 - IRG/WP 95-10131
The severe termite hazard in Hawaii, principally due to the presence of the Formosan subterranean termite (Coptotermes formosanus Shiraki), has long required the use of preservative-treated lumber in building construction. This hazard has also favored and stimulated field research in Hawaii on methods of protection from termite attack, including evaluation of soil insecticides and treated wood und...
J K Grace


Silafluofen: Novel chemistry and versatility for termite control
1995 - IRG/WP 95-30069
A novel silicon - containing insectizide, HOE 084498 ('Silafluofen'), with a favourable toxicological profile, has shown activity against a broad spectrum of agricultural and environmental health pests. Results from laboratory and field studies around the world have demonstrated that silafluofen is effective at protecting timber from attack by various species of termite and wood-...
A J Adams, A Jermannaud, M-M Serment


Standard principles of testing termiticides: A discussion paper
1991 - IRG/WP 1502
Recent restrictions and banning of termiticides such as organochlorines in some countries has focussed attention on the need for new and novel compounds as termiticides. However, this poses problems for both wood preservative manufacturers and termitologists. Test procedures have to be devised to evaluate the new termiticides so that the tests are practical, encourage vigorous termite activity, an...
J R J French


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Termite resistance classification of some tropical and temperate species based on the laboratory choice test results against formosan termite, Coptotermes formosanu
2004 - IRG/WP 04-20291
The results of classification of termite durability were varied. We carried out laboratory evaluation of the classification of termite durability on various species by the choice test against formosan termite, Coptotermes formosanus. We classified five grades (very sensitive to very resistant). According to our results, azobe, ipe, keruing, intsia, kapur, yellow meranti, jarraah, malas, cypres...
K Suzuki


Gaseous treatment of timber with allyl isothiocyanate. Fungicidal and insecticidal effects
1996 - IRG/WP 96-30108
Gaseous treatment with allyl isothiocyanate (AIT) was tested for its effects on the growth of microorganisms on the wood substrate and the mortality of subterranean termites and powder-post beetles. Toxic limits of AIT were determined as concentrations in the air when an AIT-treated filter paper was placed in a sealed container with fungus-inoculated wood specimens. Those were <3.8 ppm for Aure...
K Tsunoda, T Yoshimura


Implications for comparability of laboratory experiments revealed in studies on the effects of population density on the vigour in groups of Coptotermes lacteus (Frogatt) and Nasutitermes exitiosus(Hill) (Isoptera: Rhinotermitidae, Termitidae)
1983 - IRG/WP 1194
The vigour - survival. and wood consumption - of groups of Coptotermes lacteus and Nasutitermes exitiosus was measured when termites were kept at different population densities (g termites/mL) by changing group size and/or volume of the holding container. A characteristic pattern emerges for subterranean-like termite species. At low population densities (<0.01 g/mL) performance of termites impr...
M Lenz, R A Barrett, E R Williams


A study on the effectiveness of didecyldimethylammonium chloride to protect wood from attack by termites
1993 - IRG/WP 93-30009
A laboratory bioassay was conducted on the ability of didecyldimethylammonium chloride (DDAC) to protect Pinus radiata D.Don wood specimens from attack by two of Australia&apos;s most economically important species of subterranean termite, Mastotermes darwiniensis Froggatt and Coptotermes acinaciformis (Froggatt). Sapwood specimens of Pinus radiata, treated to achieve nominal retentions of 0.5...
J W Creffield


Report on the efficacy and performance of the insecticide candidate termiticide in H2 field trials
2004 - IRG/WP 04-10516
This paper explains the field results of phenol pyrazole treated timber against in an above ground mound colonies of Coptotermes acinaciformis (Froggatt). C. acinaciformis (‘termites’) are the major pest of human structures throughout tropical and sub tropical regions, causing billions of dollars in damage to timber-in-service worldwide. The result of this field test have shown that candidate ...
B M Ahmed, P Vinden, J Hann, J R J French


Is termite body size correlated with colony vigor?
1995 - IRG/WP 95-10130
Folk wisdom among termite researchers holds that the average body size (mass) of workers in a subterranean termite colony (Rhinotermitidae) is associated with the age and/or vigor of the colony. In particular, extremely large individuals are frequently thought to indicate a very old, or senescent, termite colony. However, there are very little data to support this assumption. It is also difficult ...
J K Grace, R T Yamamoto, M Tamashiro


Termite likes steamed larch wood
1995 - IRG/WP 95-10113
Steamed wood of Japanese larch (Larix leptolepis (Sieb. et Zucc.) Gord.) was preferably attacked by termites. Steam treatments have often been applied to Japanese larch wood for improving its penetrability or color. For preventing termite attack on steamed timber, we have to elucidate why termite likes it. Choice tests with Coptotermes formosanus Shiraki were conducted using larch boards steamed f...
S Doi, M Kubota, M Takahashi, T Yoshimura, A Adachi


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Assessment of the Termatrac™ system - a new microwave based technology for non-destructive detection of termites
2003 - IRG/WP 03-20265
Termites can be difficult to detect reliably and many detection methods are destructive to property or disturbing to the termites (which may interfere with remedial treatment). The reliability of Termatrac™, a new Australian device for the detection of termites in an unobtrusive manner, based on novel microwave technology, was tested in the field. Termite presence was assessed as indicated by th...
T A Evans


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Comparison of permethrin and fenvalerate as termiticides and their significance to Australian Quarantine Regulations
1984 - IRG/WP 1230
This paper reports detailed laboratory evaluations of the termiticidal efficacy of permethrin and fenvalerate-treated wood blocks. Comparison between artificially wheathered permethrin-treated blocks and unweathered blocks is given. The effect of a 6-week soil burial period on pyrethroid-treated blocks at a retention of 0.08 kg/m³ is also reported. Toxic or protection threshold values for the two...
J W Creffield, C D Howick


Variable chlordane residues in soil surrounding houses in Louisiana
1989 - IRG/WP 1404
Eight soil samples from each of 30 houses in greater New Orleans, Louisiana were collected in October, 1986 and analyzed for chlordane residues (ppm). All houses had reportedly been treated in the late 1960&apos;s or early 1970&apos;s. Chlordane occurred in all samples, and the overall mean (+ SEM) was 870.6 + 96.5 ppm. Residue levels were unaffected by construction type (slab, crawl, craw...
J P La Fage, K S Delaplane


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Relationship between the bending strength and the degree of termite attacks on western hemlock by Coptotermes formosanus Shiraki
1990 - IRG/WP 1434
For the examination of the relationship between the bending strength and the degree of termite attacks, Western Hemlock (Tsuga heterophylla Sarg.) was used. Sixty specimens (4.5 x 4.5 x 82 cm³) were attacked by termites at the culture room of Coptotermes formosanus Shiraki. The termites were introduced on the central parts (10 cm) of specimens. In the case of the 2 points loading, the bending mom...
K Suzuki, T Tanaka


Biological resistance of electrolessly plated wood (1). Preliminary report
1994 - IRG/WP 94-40024
Surface metal coating is considered to improve biological resistance of wood as some metal ions are fungitoxic. Six wood species (three softwoods: Cryptomeria japonica, Tsuga heterophylla and Larix spp; three hardwoods: Fagus crenata, Acer mono and Betula platyphylla) were electrolessly plated with nickel or copper, and those were served for laboratory evaluation of their resistance against decay ...
M Hasegawa, K Tsunoda, T Yoshimura


Detection of metabolic gas from termites using ceramic gas sensors
2001 - IRG/WP 01-20222
To evaluate termite attacks in wooden constructions by detecting the metabolic gas from termite colony, the basic performance of three types of ceramic gas sensors (odor-, methane- and hydrogen-selective sensors) was investigated. Four termite groups of different combinations of workers (100 to 1000) and soldiers (10 to 100) of Coptotermes formosanus Shiraki and a small specimen of Japanese red pi...
Y Yanase, Y Fujii, S Okumura, T Maekawa, K Suzuki, T Yoshimura, Y Imamura


Previous Page | Next Page