IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 1150 documents. Displaying 25 entries per page.


Evaluation of polymeric alkylphenol polysulfide as a new wood preservative compound
2000 - IRG/WP 00-30251
At the 30 th IRG meeting held in Rosenheim, Bavaria, Germany, we reported on a Polymeric Alkylphenol Polysulfide (PXTS) which shows potential as a new non-leachable, environmentally compatible wood preservative compound exhibiting excellent biocidal efficacy. Comparative soil-block test results showed that PXTS was twice as effective as Creosote when evaluated against both white- and brown-rot fun...
J Goswami, A Abramson, R Buff, D D Nicholas


Effect of compression wood on leaching of chromium, copper, and arsenic from CCA-C treated red pine (Pinus resinosa Ait.)
2000 - IRG/WP 00-30232
In this study, the effect of compression wood formation on the release rate of chromium, copper, and arsenic elements from red pine (Pinus resinosa Ait) was investigated. Wood blocks from red pine containing compression and normal wood portions were treated with a 1.0% CCA-C solution and were then allowed to fix at 23 ± ??2°C (74 ± 4°F) for 0, 6, 24, 48, 96, 192, and 336 hours. After each fixa...
S N Kartal, S T Lebow


Industrial fixation of chromium based wood preservatives
1990 - IRG/WP 3630
Fixation is an abstract and non-defined process. Nevertheless it is a specified requirement in most impregnation standards. The impregnation industry is facing increased pressure to deliver fixed products and to increase the safety of the handling of impregnated products. Industrial fixation of impregnated wood can be obtained by using different methods. The purpose of the process is to transform ...
T Christensen


A technical note on the limitations of atomic absorption spectrophotometric analysis of copper/chrome/arsenic solutions according to BS 4072 (1974) and BS 5666: Part 3 (1979)
1988 - IRG/WP 2320
British Standards BS 4072 (1974) and BS 5666: Part 3 (1979) detail an atomic absorption spectrophotometric method for the quantitative determination of copper, chrome and arsenic in both preservative solutions and treated timber. Use of this technique during a research programme at Aberdeen has highlighted some potential inaccuracies with this method if these standard specifications are adhered to...
A J Pendlebury, J A Petty


The multi-phase pressure (MPP) process. One-stage CCA treatment and accelerated fixation process - The process as a new concept in preservative treatment
1997 - IRG/WP 97-40078
The background to current commercial CCA treatment schedules used in New Zealand and fixation processing is reviewed. The limitations of these conventional practices with respect to treated product quality and CCA solution handling issues are defined. A novel, patented treatment schedule has been developed using a combination of hydraulic and pneumatic pressure phases and hot (~ 75°C) CCA solutio...
K Nasheri, A J Pendlebury, J A Drysdale, H Pearson, M E Hedley


Chemical Analysis of Southern Pine Pole Stubs Thirteen Months Following Treatment with Three Methylisothiocyanate Based Commercial Fumigants
2002 - IRG/WP 02-30294
Agricultural fumigants have been commercially used in the United States for over 20 years to control internal decay in utility poles and other wooden structures. Of the four fumigants which are currently used in the remedial treatment of utility poles, three are based on methylisothiocyanate (MITC) as being the principal fungitoxic component. Two of these MITC based fumigants, liquid metham sodi...
R J Ziobro, T C Anderson, D J Herdman, J Guzzetta, T Pope


Stake test with ammoniacal copper in combination with different agents started in 1962
1997 - IRG/WP 97-30130
In 1962 a stake test was started with ammoniacal copper in combination with chromium, arsenic, pentachlorophenol, boron, salicylic acid, benzoic acid, sorbic acid, pyridine and tannin. Different concentrations of the copper component were used as well as the added agents. For each concentration and test site, ten stakes of Pinus sylvestris L. sapwood were treated. The stakes were set out at two te...
B Häger, Ö Bergman


Review of current wood preservation in Turkey
2003 - IRG/WP 03-30315
The aim of this study was to find out the current potential of the Turkish wood preservation industry, and to make some suggestions for its further proceeding, because the forest products potential and the geographical location combined may give to the wood preservation industry in Turkey a great advantage for exportation treated wood materials to the Middle East Countries. In this study, therefo...
I Usta


The effects of preservative treatment and exposure to wood degrading fungi on fiber reinforced polymer (FRP) materials used for structural wood reinforcement
2001 - IRG/WP 01-40204
Glass fiber reinforced phenolic (GFRP) composite materials are becoming increasingly accepted for use in the construction industry because they combine advantages of both wood and advanced polymeric materials. Addition of only 1-3% FRP in the tension zone, for example, can typically improve the strength of the hybrid system by 200%. As more applications are found for wood/FRP hybrids, (e.g. lamina...
C Tascioglu, B Goodell


Preservative technique of three commercially important timber species – Sissoo (Dalbergia sissoo), Akasmoni (Acacia auriculiformis) and Ghoraneem (Melia azedarach) of Bangladesh
2005 - IRG/WP 05-40299
Wood is renewable resource and is widely used as construction material in rural and urban areas of Bangladesh. Dalbergia sissoo, Acacia auriculiformis and Melia azedarach, locally known as Sissoo, Akasmoni and Ghoraneem respectively are three important timber species of Bangladesh. These are used for different purposes normally without preservative treatment. Heartwood of Sissoo, Akasmoni and Ghor...
M R Bulbul, M O Hannan, P K Sarker, A A Mahafuz, G N M Ilias


Assessment of the Termatrac™ system - a new microwave based technology for non-destructive detection of termites
2003 - IRG/WP 03-20265
Termites can be difficult to detect reliably and many detection methods are destructive to property or disturbing to the termites (which may interfere with remedial treatment). The reliability of Termatrac™, a new Australian device for the detection of termites in an unobtrusive manner, based on novel microwave technology, was tested in the field. Termite presence was assessed as indicated by th...
T A Evans


Performance of groundline bandage remedial treatments in western US species transmission poles
1993 - IRG/WP 93-30019
Groundline bandages are an important element in remedial treatment strategies for utility poles in the United States. Several bandages containing new or reformulated components have recently been developed but have not been adequately tested. This paper reports on the degree of diffusion of copper naphthenate, boron, and sodium fluoride from groundline bandages into pressuretreated Douglas-fir, po...
P G Forsyth, J J Morrell


Comments on leaching in view of accelerated testing
1977 - IRG/WP 294
We developed an accelerated test for leaching at elevated temperatures (75-85°C). This test was used for the examination of 11 preservative formulations containing Cu, Zn and As. The data obtained from these experiments were compared with data on some formulations tested by ASTM standard leaching test. The method consists in making a large surface to volume ratio of wood from a treated block by c...
J Rak


Wood preservatives. The state of French legislation (June 1977)
1977 - IRG/WP 3106
There does not exist any special legislation for preservatives but general laws may intervene at three levels:-Manufacture -Transport -Selling. In every case, it is based on a poisonous substances classification, an official classification provided by a para-governmental organisation which includes toxicologists. This legislation may refer to other texts: categories of danger for transport (the Eu...
M Romeis, P Guéneau


A comparison of analytical techniques
1995 - IRG/WP 95-20061
This paper compares carefully-controlled weight retentions and analysis by XRF, ICP, combustion methods and a new extraction procedure for the new preservative, Copper(II) Dimethyldithiocarbamate (CDDC). Various experimental parameters such as particle size and drying conditions were investigated. In general, the correlations between and among the procedures are very high. The extraction-colorimet...
A C Gallacher, C R McIntyre, M H Freeman, D K Stokes, W B Smith


Development of software to automate the quantification of checking occurring in preservative treated wood exposed to weathering
2001 - IRG/WP 01-20228
Surface checking often disfigures the appearance of wood treated with water-borne preservatives and treatments designed to reduce such checking have been receiving increasing attention. Progress in this area has however been slowed by the lack of a method of rapidly and accurately quantifying checking at treated wood surfaces. A software package has therefore been developed which identifies, measu...
A G Christy, P D Evans


Microdistribution of Copper in Copper-Ethanolamine (Cu-EA) Treated Southern Yellow Pine (Pinus spp.) related to density distribution
2004 - IRG/WP 04-40270
The relationship between copper absorption and density distribution in wood cell walls was investigated in this study. The density distribution on layer level was obtained from two approaches: (1) calculation by using data obtained from literature; (2) microdistribution of carbon and oxygen atoms in the wood cell. The microdistribution of carbon and oxygen in untreated southern yellow pine (Pinus ...
Jinzhen Cao, D P Kamdem, E Pasek


Effect of treatment process on performance of copper-chrome-arsenate. Part 1: Fungus cellar tests
1995 - IRG/WP 95-40045
Pinus radiata sapwood stakes 20 x 20 x 400 mm³ were treated with CCA Type C using a range of concentrations and three treatment processes; Bethell, Lowry and Rueping. Preservative retention was determined by chemical analysis of treated material. Following fixation, fungus cellar stakelets, 5 x 10 x 180 mm³ were cut from treated material and after leaching were exposed in unsterile soil beds in ...
M E Hedley, J Anderson, J B Foster, B E Patterson


CCFZ, a new type of water-borne wood preservative for vacuum pressure impregnation
1991 - IRG/WP 3643
By combination of CCF-Salt types with zinchexafluorosilicate a remarkable improvement of efficacy is achieved. In the same time the ecotoxicoligical data become more save. As well as the efficacy against wood-destroying organisms (Basidiomycetes, Soft rot and Long horn beetle) the basic data to evaluate the ecotoxicological behaviour of a CCFZ-Salt are described and compared with the properties of...
W Metzner, D Seepe, H-W Wegen


The preventive effectiveness of preservative treatments against wood-rotting fungi. Preliminary results
1992 - IRG/WP 92-2407
The efficacy of a range of preservative treatments in preventing colonisation by decay fungi has been assessed using a method developed at BRE and similar to that adopted by Working Group 9 of European Standards Committee CEN/TC 38. Assessment was made using baits inserted into the test blocks, in holes which had been drilled after treatment to within defined distances of the treated face exposed ...
J K Carey


Management strategies for the disposal of CCA-treated wood
2000 - IRG/WP 00-50155
A two-fold management strategy is presented for the disposal of wood treated with chromated copper arsenate (CCA). The first part focuses on the use of alternative wood treatment preservatives. The second part of the management strategy addresses short-term disposal issues (less than 25 years) by developing new methods to handle the waste. A set of seven alternative wood preservatives were evaluat...
H M Solo-Gabriele, T G Townsend


Methods for the assessment of wood preservative movement in soil
1995 - IRG/WP 95-50040-08
This paper presents preliminary results from a series of experiments constructed to provide laboratory data for the evaluation of the leaching of wood preservatives into and through soil. The experiments included: i) measurement of the adsorption of preservatives by soil; ii) determination of the concentration gradient of preservatives in soil following percolation of preservative solution through...
G E Holland, R J Orsler


Determination of corrosive effect of liquid wood preservatives to metals – First experiences with a National Standard which is in revision
2006 - IRG/WP 06-20321
The development of standards is an essential tool to characterise different kind of materials and products. An important aspect during the development of a new product is to check the corrosion behaviour with other materials. Corrosion can cause several problems like pitting corrosion. Consequently the knowledge concerning the corrosive effect of liquid wood preservatives is important due to the s...
E Melcher


Reappraisal of some fungicides by the amended JWPA method
1992 - IRG/WP 92-3689
Organoiodine compounds which have been commercialized these years in Japan poorly performed as fungicides in the amended JWPA decay test (Standard 1, 1989) when applied to superficial treatment of timber. Because some parts of active ingredients seemed to disappear from the treated timber surface mainly due to the severe leaching cycles. This was prominently true for beech (Fagus crenata Blume) sa...
K Tsunoda


Resistance of acrylic paints on wood against growth of the rot fungus Dacrymyces stillatus
1990 - IRG/WP 2345
In the last few years the presence of the rot fungus Dacrymyces stillatus has been repeatedly confirmed in external wood panels, particularly from wood painted with water based paints. A laboratory method for testing of the fungal resistance of paint films on wood has been developed.This method has been used to test the efficacy of the fungicides Parmetol DF 18 and Parmetol HF 25 against attack by...
J Bjurman


Previous Page | Next Page