IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 849 documents. Displaying 25 entries per page.


An appraisal of methods for environmental testing of leachates from salt-treated wood (2)
1998 - IRG/WP 98-50110
For wood preservatives for use in hazard class 4 information on the ecotoxicity of preservatives and ingredients as well as on the effect of losses from impregnated timber is needed for a proper environmental risk assessment. In the evaluation of a suitable test procedure the leaching behaviour of copper-based formulations was studied using analytical and ecotoxicological test methodology. These ...
H W Wegen, A Platen, G M F Van Eetvelde, M Stevens


An Australian test of wood preservatives. - Part IV: The condition, after 35 years' exposure, of stakes treated with creosote oils and oilborne preservatives
2000 - IRG/WP 00-30241
This paper contains the first results dealing with creosote oils and oilborne preservatives from this in-ground field trial in Australia. The substrates impregnated with preservative were Pinus radiata D. Don sapwood and Eucalyptus regnans F. Muell. heartwood and sapwood. Data are reported from stakes exposed for 35 years at three Australian sites (Innisfail, Sydney, Walpeup). Comparisons were mad...
G C Johnson, J D Thornton


Spot-tests for TnBTO and AAC preservatives
1984 - IRG/WP 3279
Nineteen indicator systems were examined as potential alternative spot-tests for preservative penetration in TnBTO- (bis-tributyltin oxide) or AAC- (alkyl ammonium compound) treated wood. Results indicated phenylfluorone as an acceptable alternative to pyrocatechol violet for assessment of TnBTO, and cobaltous thiocyanate or a bromocresol green/quinine sulphate mixture as alternatives to bromophen...
D V Plackett


Biocides - Efficacy assessment and doses for wood preservatives (product type 8). Local/geographical aspects. Termite control as case study
1999 - IRG/WP 99-20181
Currently, the efficacy of a wood preservative, as biocidal product type 8, is assessed as a ‚critical value' (CV), an efficient dose (retention in wood at a given depth of penetration). CVs are planned to be adapted for exposure to basic target organisms (5 hazard classes) and additional requirements concerning the occurrence of local target organisms in relation with climate, building...
G Ozanne


Diffusion of bifluorides and borates from preservative rods in laminated beams
1991 - IRG/WP 3644
Laminated beams from spruce, pine and larch were treated with two preservative rods, based on bifluorides and octaborate respectively. After 3 and 6 months placed in different climates (65% r.h., 100% r.h., water) the diffusion of the active ingredient was measured. After the 6 months period, the diffusion of the bifluorides was, in all species, ca. 5 times larger than the diffusion from octaborat...
H Militz


Copper based water-borne preservatives: The biological performance of wood treated with various formulations
1987 - IRG/WP 3451
Wood samples treated with the various components of CCA preservative singly and in combination were tested against a soft rot organism, a copper tolerant brown rot organism and in soil burial both unleached and after leaching. The results suggest that, of the elements tested, fixed copper is essential for preventing soft rot attack and fixed arsenic is essential for preventing attack by a copper t...
S M Gray, D J Dickinson


Seasonal effects of the field evaluation on wood preservatives against mold fungi
1996 - IRG/WP 96-20087
For the purpose of the amelioration of field test methods, commercial preservatives against mold fungi were tested under two different seasons, in winter and in summer. The specimens were bundled and set over the water bath and all these systems were covered with plastic film. At top of the system under film, black films for regeneration of sunlight were put in, and windows for changing air were r...
K Suzuki, Y Sugai, K Ryugo, D Watanabe


Evaluation of the leach resistance and preservative efficacy of novel biocides as surface treatments applied by brush to spruce (Picea abies)
1998 - IRG/WP 98-30170
The comparative leach resistance and preservative efficacy of a number of alternative organic preservatives (available from Zeneca Specialties) and selected commercially available biocides as surface coatings to wood in Hazard Class 3 have been assessed. Two concentrations of test preservatives were applied by brush to Spruce (Picea abies), including formulation and untreated controls. A leaching ...
I M Tierney, A Bruce, D C R Sinclair, T Yeates


Waterborne silicones as wood preservatives
1995 - IRG/WP 95-30062
For more than thirty years silicones are used as water repellents for masonry. Their excellent properties make them also attractive for non-mineral substrates like wood. Although it was always thought that silicones are not able to perform on wood, a new type of aqueous silicone materials proofed the opposite: Excellent water repellency and astonishing durability were achieved. This paper describe...
R Hager


Quelques observations biologiques sur la conduite des essais de protection des bois immerges en milieu marin
1976 - IRG/WP 421
P Deschamps


Tests on preservation of wood against marine borers
1976 - IRG/WP 417
The Instituto del Legno has carried out for some years a series of trials about the biodeterioration of wood in the sea. The investigations included the settlement and activity of marine borers, the natural durability of indigenous and tropical woods and the preservation of wood for marine use. This paper reports the trials on the effectiveness of some preservatives in protecting wood against mari...
A Gambetta, E Orlandi


Thirty-four year test of on-site preservative treatments to control decay in wood above ground
1993 - IRG/WP 93-30015
This research was initiated in 1958 to investigate efficacy of various preservatives and treating methods for new lumber going into exterior structures of buildings. Post-rail units (2x4 inches) constructed of Southern Pine sapwood, Douglas-fir heartwood, and mill run western hemlock were dip- or brush-treated before or after assembly. Units were trested with pentachlorophenol in various petroleum...
T L Highley, T C Scheffer


Safety clearance of wood preservatives in United Kingdom
1977 - IRG/WP 398
In the United Kingdom the principal route of control of pesticides is through the Pesticides Safety Precautions Scheme (PSPS) which is a non-statutory scheme agreed between government ministries and departments (referred to as "Departments") and associations representing the pesticide industries. The scheme formally began in 1957 covering those pesticides and related substances used in agriculture...
J M Baker


Collaborative tests on the influence of solvent and drying method on the toxic limit of wood preservatives against Basidiomycetes
1974 - IRG/WP 248
Seven institutes from five countries, Austria, England, France, Germany and the Netherlands have collaborated in a study on the influences of solvent and drying method on the toxic limits of wood preservatives against Basidiomycetes tested according to the agar-block method. Two preservatives, a 25% pentachlorophenol-concentrate and tributyltinoxide were applied to pine sapwood and beech and teste...
T Hof


The secondary treatment of creosoted electricity poles with fused boron rods
1988 - IRG/WP 3485
After preliminary trials selected poles were treated at the groundline with fused boron rods. Early samplings showed that movement was slow in the dry heartwood but after six years the distributions obtained indicate that the system has merit for the treatment of the heartwood of poles in service....
D J Dickinson, P I Morris, B Calver


Investigation of the fixation in wood of chromated zinc chloride and copperised chromated zinc chloride preservatives
1976 - IRG/WP 372
A biological method of evaluating the extent to which CZC and CCZC preparations are retained in wood in terms of the potential protection which they afford against destruction by Merulius lacrymans (dry rot) is given. CCZC is recommended for protection of wood under moderate leaching conditions, while the use of CZC under such conditions is not recommended....
V N Sozonova, D A Belenkov


Environmental exposure to wood preservatives
2000 - IRG/WP 00-50165
The OECD Working Group on Pesticides will hold a workshop on Assessing Environmental Exposure to Wood Preservatives within the context of its Biocides Programme (cf. IRG/WP 99-20182). In the area of risk assessment, OECD countries have given highest priority to developing guidance on how exposure assessments for biocides should be performed. Wood preservatives have been selected since most countri...
R-D Peek


Biological effectiveness of ground-contact wood preservatives as determined by field exposure stake tests
1984 - IRG/WP 3297
Field exposure tests conducted on stakes treated with different creosotes, mixtures of creosote and waxy oil as well as different CCA wood preservatives over a period of 25 years, gave the following results: The CCA preservatives provided excellent biological protection to treated stakes, especially against fungal attack. The CCA Type I, currently approved for use under South African conditions is...
W E Conradie, A Pizzi


Practical testing of wood preservatives to prevent weathering damage and infection by micro-organisms on spruce and pine
1989 - IRG/WP 3530
Brush application, is generally used to prevent wooden window frames from decay caused by influence of weathering and fungi. Accordingly 10 boards of pine (Pinus sylvestris) and spruce (Picea abies) were treated with 10 commercially used wood preservatives. The efficiency of fungicides by using chiptest and blue stain test (EN 152), the effectiveness against weathering as well as the course of col...
R Gründlinger, O Janotta, H Melzer, K Messner


Preservación de maderas en Bolivia
1986 - IRG/WP 3360
Este documento ofrece datos generales concerníentes a los recursos forestales de Bolivia, las facilidades existentes para preservación de maderas, la investigación y educación en esa materia. Se proporciona información sobre instituciones vinculadas a la actividad y las perspectivas del tratamiento de maderas en el país....
A S Viscarra


New conception for shortering the duration of fungitoxic test of wood preservatives. Part 3: Proposal for interlaboratory test on miniaturisation of wood specimens
1994 - IRG/WP 94-20053
In connection with documents IRG/WP 94-20044 and IRG/WP 94-20052 the proposal for interlaboratory test on miniaturization of wood specimens is given....
J Wazny, J J Krajewski


A method for determining boron diffusion coefficients in wood
1999 - IRG/WP 99-30200
The radial unsteady-state diffusion coefficient for boron in southern yellow pine (Pinus spp.) was determined from measured concentration profiles using Egner's solution, a modified form of Fick's second law. The method uses a slicing technique to accurately determine concentration gradients with time in a single direction. The methodology should be applicable to any diffusible s...
J-B Ra, H M Barnes


Evaluation and approval of wood preservatives. Unification of European requirements
1988 - IRG/WP 2310
This paper reviews the current activities within the European Homologation Committee for Wood Preservatives (EHC) towards unification of the requirements on evaluation and approval of wood preservatives in Western European countries....
J Jermer


Health and safety aspects of the use of wood preservatives. Preliminary evaluation of the answers to the IRG-Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 56
This preliminary evaluation of the answers to the IRG/WP-Questionnaire only gives a general survey on those questionnaires, which the author received until June 13, 1974. Details, such as correlations between importance of wood preservation and pollution control, could not be considered due to lack of time. For the same reason it was not possible so far, to evaluate the additional remarks given in...
H Willeitner


Fungal degradation of wood treated with metal-based preservatives. Part 2: Redox states of chromium
1996 - IRG/WP 96-10164
Concerns have arisen about the leaching of heavy metals from wood treated with metal-based preservatives, such as chromated copper arsenate (CCA). Of particular concern is the toxic redox state of chromium and arsenic in aging and decayed CCA-treated wood. Generally, hexavalent chromium is more toxic than trivalent chromium and trivalent arsenic is more toxic than pentavalent arsenic. The desired ...
B Illman, S Bajt, T L Highley


Previous Page | Next Page