IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 43 documents. Displaying 25 entries per page.


A method and apparatus for rapid assessment of termite barriers.
2007 - IRG/WP 07-20366
This paper describes an apparatus for rapid assessment of barriers to subterranean termite foraging. The method and apparatus arose from the development of a novel physical termite barrier. The barrier had to be flexible, resilient, able to be applied as a liquid and be neither toxic nor repellent. This posed a special problem as existing laboratory assessment techniques did not offer a sufficient...
D McG Ewart


A hypothesis on a second non-biocidal property of wood extractives, in addition to toxicity, that affects termite behavior and mortality
2008 - IRG/WP 08-10638
While it is has long been recognized that heartwood extractives affect termite behavior, the exact cause and relationship between total extractives, extractive types, and termite resistance remains unclear. Generally, researchers have proposed that the extractives are toxic and/or repel termites. We propose, based on the well known fact that many extractives have excellent antioxidant properties...
T P Schultz, K Ragon, D D Nicholas


Performance of sintered glass screening as a potential physical barrier against subterranean termites in the laboratory and after 4 years of field test
2008 - IRG/WP 08-10646
This paper describes the performance of sintered glass screenings as a potential physical barrier against the subterranean termites, Coptotermes acinaciformis and Mastotermes darwiniensis in the laboratory and after four years of field testing in active above-ground mound colonies of Coptotermes lacteus. The laboratory results suggest that sintered glass is a viable control option against Copto...
J R J French, B M Ahmed (Shiday)


Whole-of-house protection from subterranean termite attack and damage after four years of field exposure
2008 - IRG/WP 08-10665
This study reports the condition of the whole-of-house termite protection test in tropical Australia after four years. The study was designed to provide maximum protection to whole-of-house timbers in a natural situation posing the highest hazard from subterranean termite populations. The houses were constructed either on concrete slabs or suspended floors using untreated and treated timber fram...
B M Ahmed (Shiday), J R J French, S R Przewloka, P Vinden, J Hann, C Y Adam


Evaluation of the natural durability of reed (Phragmites australis) originating in the Fertö region (Hungary) against wood decay organisms as material for use in a sustainable motorway noise barrier
2009 - IRG/WP 09-10685
This work presents the research carried out to determine the natural durability of reed from the Fertö region of Hungary against wood decay organisms. The final objective of this study is to obtain sufficient relevant data in order that the reed may be used as a constituent element in a viable and sustainable motorway noise barrier, which has been developed within the European research project, k...
M T Troya, F Rubio, M J Prieto, D Lorenzo, J L Fernández-Cabo, R Schöftner


Review of candidate graded particle barrier testing methods in Australian Standard (AS 3660.3 – 2000): Assessment criteria for termite management systems
2009 - IRG/WP 09-20417
The Australian Standard (AS. 3660.3 – 2000) for assessment of candidate graded particle termite barriers is reviewed and suggestions for amendments are made. Areas requiring amending in light of current biological knowledge involve the inclusion of proprietary or patented systems rather than generic types; selection of test termites in the genus Coptotermes; duration of test periods; and inadequ...
J R J French, B M Ahmed (Shiday), B L Schafer


Preliminary laboratory and field evaluation on the performance of Rubbermite as a graded physical barrier against subterranean termite species in Australia
2012 - IRG/WP 12-10766
This paper describes the performance of Rubbermite as a potential graded particle barrier against two subterranean termite species of Coptotermes in laboratory and field test. The results of these bioassays suggest that Rubbermite is a viable control option against Coptotermes species in Australia, particularly against Coptotermes acinaciformis (Froggatt) and Coptotermes lacteus (Froggatt). Rubber...
B M Ahmed (Shiday), J R J French


Managing termite risks – An Australian perspective and a cautionary tale
2012 - IRG/WP 12-20482
The management of the risks of termite attack on new buildings in Australia falls to a range of agencies and is mostly achieved through controlling the process by which structures are certified as complying with the Building Code of Australia. Australian Standard AS3660 parts 1, 2 & 3 have historically been the core of this function but now the Building Codes Board's own certification scheme,...
D Ewart


Laboratory investigation of fire protection coatings for creosote-treated timber railroad bridges
2014 - IRG/WP 14-30639
As the incidence of timber railroad bridge fires increases, so has the need to develop protective measures to reduce the risk from accidental ignitions primarily caused by hot metal objects. Of the six barrier treatments evaluated in the laboratory for their ability to protect timbers from fires sourced with ignition from hot metal objects only one intumescent coating provided adequate fire prote...
C A Clausen, R H White, J P Wacker, S T Lebow, M A Dietenberger, S L Zelinka, N M Stark


Field Performance of Old-Growth and Second-Growth Western Red Cedar Fence Posts with and without Barrier Wraps
2015 - IRG/WP 15-10838
Many authors have suggested natural durability may be lower in second-growth western redcedar than in old-growth. One potential means of offsetting a decline in durability is use of physical barriers to separate the wood from soil. In the present work we compared the durability of old-growth and second-growth western red cedar posts, with and without barrier wraps, in a field test. After ten year...
P I Morris, J K Ingram, R Stirling


Termite Management and the U.S. Experience: A Case for Wood Treatment & Integrated Control
2015 - IRG/WP 15-30678
A brief overview of termite control is given using specific experiences from the U.S.A. Five major types of termite treatment now prevail: soil applied chemical barriers, in-structure chemical barriers (in-situ applied wood and foundation treatments), physical barriers, treated wood and termite baits. In general, ‘stand-alone’ pretreatments or ‘primary’ treatments are often discussed and ...
J D Lloyd, K van den Meiracker


Encapsulation of poles to prevent moisture uptake – a laboratory test
2016 - IRG/WP 16-40753
Premature failure of utility poles due to decay in soil contact is the main reason for early removal of utility poles, a measure that implies extra costs for utilities. Remedial treatments and barriers are common methods to prolong the service life of utility poles. The first part of this paper gives an overview of mode of action and commercial application of barrier systems as described in the li...
K-C Mahnert, U Hundhausen


Evaluation of Particulate Materials as a Physical Barrier against Termites under Floor of Experiment House
2017 - IRG/WP 17-10900
In Japan, the damages by the subterranean termites (Coptotermes formosanus and Reticulitermes speratus) are more common. Recently the more attention is paid to the less- or non-chemical methods for termite control. As a non-chemical treatment, physical barriers using particles such as gravels were investigated in terms of environmental safety, cost effectiveness, and duration of performance, and t...
Y Yanase, Y Fujiwara, Y Fujii, T Mori, T Yoshimura, S Doi


Evaluation of the Virulence of the Termite Species Occurring in the French Tropical Overseas Territories
2018 - IRG/WP 18-10913
The French tropical overseas territories are strongly affected by termites’ activity, which is especially devastating because the species encountered there are among the most virulent in the world. That is why in these regions it is particularly important that producers and users of wood-based products are provided with materials and preservative products whose durability and efficacy has been t...
M Kutnik, I Paulmier, J Vuillemin


Preventivephysical barriers against subterranean termites species for building protection: How to implement innovative materials to reach efficacy requirements
2018 - IRG/WP 18-40845
As the European regulation dealing with the use of biocides (BPR) for preventive protection of buildings against subterranean termites is leading to more and more pressure on physico-chemical barriers currently used (PT18), some existing developments are focusing attention on physical biocides-free barriers. The main target is then to avoid the use of active ingredients, to stay out of the BPR sco...
N Delourme-Fonseca, P Poveda, F Simon


Environmental protection and long term in-service sustainability of preserved wooden poles is secured by non-toxic barrier protection system – History and case studies in South Africa
2018 - IRG/WP 18-50340
Non-toxic flexible sheeting systems have been developed to encapsulate the ground contact regions of preserved wooden poles and prevent their premature failure in South Africa since 1992 but the technology also has a long history of resistance by individuals with vested interests in the built-in redundancies of such poles. The concept has, however, been simultaneously validated by many independent...
A A W Baecker


Performance of a noise barrier with different wood materials – results from a service trial after 25 years of exposure
2023 - IRG/WP 23-30776
In connection with the construction of the railway connection between Stockholm Arlanda airport and Stockholm city, an 11 km long noise barrier made of untreated European larch was built along the railway line. This provided an opportunity to implement a full-scale study comparing different untreated wood species and preservative treatments. Thus, in March 1996 ten test sections including untreate...
J Jermer, M Westin


Establishing the minimum effective penetration of wood preservatives in the refractory heartwood of E. nitens
2023 - IRG/WP 23-30780
Conventional pressure treatment of many Australian hardwoods results in little to no penetration of heartwood and a non-uniform envelope treatment of <5 mm surrounding a mostly untreated core. This is a major issue for many of the low durability plantation hardwood timbers that are grown in Tasmania, which contain high percentages of heartwood. Long term studies on softwoods such as spruce decking...
J R Vargas, J J Morrell, L Yermán, K C Wood


Previous Page