IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 1069 documents. Displaying 25 entries per page.


Comparison of the in-ground performance of pigment emulsified creosote (PEC) and high temperature creosote (HTC)
2000 - IRG/WP 00-30217
A long-term field trial was conducted in Australia to compare the in-ground performance of two oil-borne preservative formulations, conventional high temperature creosote (HTC) and a modified creosote formulation, pigment emulsified creosote (PEC). Three retentions (50, 100 and 200 kg/m³) were targeted for each formulation. An additional retention of PEC formulation (308 kg/m³), which contained ...
J W Creffield, H Greaves, N Chew, N K Nguyen


Environmentally benign wood preservatives based on organic biocide antioxidant combinations: A brief review of laboratory and field exposure results and discussion of a proposed mechanism
2004 - IRG/WP 04-30335
The combination of various organic biocides with commercial antioxidants generally increased the biocides’ efficacy 2-3 fold against wood-destroying fungi in short-term laboratory decay tests, and some positive results have been obtained after 2-4 years of outdoor exposure. The two antioxidants principally examined, propyl gallate and butylated hydroxytoluene, are low cost and, since both are f...
T Schultz, D D Nicholas, W Henry, C Pittman, D Wipf, B Goodell


Development of a mini-block test method for the rapid evaluation of preservative performance against Basidiomycte fungi
1991 - IRG/WP 2379
Screening procedures for new biocides used as wood preservatives can be a time consuming process using conventional Basidiomycete assay procedures. This is due mainly to the long exposure periods required to achieve adequate levels of decay (weight loss) in the test blocks. A number of alternative methods have been developed but most utilise artificial substrates such as filter paper or agar in wh...
J Brown, S Caswell, G R Williams


In ground performance of wood treated with a substituted isothiazolone
1990 - IRG/WP 3612
Isothiazolones (I.T.A.'s) are a class of biocides that have potential for use as wood preservatives. The substituted ITA, RH-287, (4,5,dichloro-2-n-octyl-isothiazolone-3-one) is being evaluated as a broad spectrum wood preservative. The evaluation program includes in ground stake tests which were established at two test sites in Mississippi, USA The tests used southern yellow pine treated...
L E Leightley, D D Nicholas


Termite likes steamed larch wood
1995 - IRG/WP 95-10113
Steamed wood of Japanese larch (Larix leptolepis (Sieb. et Zucc.) Gord.) was preferably attacked by termites. Steam treatments have often been applied to Japanese larch wood for improving its penetrability or color. For preventing termite attack on steamed timber, we have to elucidate why termite likes it. Choice tests with Coptotermes formosanus Shiraki were conducted using larch boards steamed f...
S Doi, M Kubota, M Takahashi, T Yoshimura, A Adachi


Evaluation of polymeric alkylphenol polysulfide as a new wood preservative compound
2000 - IRG/WP 00-30251
At the 30 th IRG meeting held in Rosenheim, Bavaria, Germany, we reported on a Polymeric Alkylphenol Polysulfide (PXTS) which shows potential as a new non-leachable, environmentally compatible wood preservative compound exhibiting excellent biocidal efficacy. Comparative soil-block test results showed that PXTS was twice as effective as Creosote when evaluated against both white- and brown-rot fun...
J Goswami, A Abramson, R Buff, D D Nicholas


An aquaria test of the natural resistance against marine borers of some commercial timbers available in Australia
1996 - IRG/WP 96-10145
The natural resistance of the heartwood of 22 different timbers grown or commercially available in Australia was examined. Radiata pine sapwood both untreated, and treated with 5.4 kg/m³ CCA salt, was included for comparison. Small timber blocks were exposed for one year in tanks containing either Limnoria tripunctata or Lyrodus pedicellatus. Four softwood species tested were heavily attacked and...
L J Cookson


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Industrial fixation of chromium based wood preservatives
1990 - IRG/WP 3630
Fixation is an abstract and non-defined process. Nevertheless it is a specified requirement in most impregnation standards. The impregnation industry is facing increased pressure to deliver fixed products and to increase the safety of the handling of impregnated products. Industrial fixation of impregnated wood can be obtained by using different methods. The purpose of the process is to transform ...
T Christensen


The multi-phase pressure (MPP) process. One-stage CCA treatment and accelerated fixation process - The process as a new concept in preservative treatment
1997 - IRG/WP 97-40078
The background to current commercial CCA treatment schedules used in New Zealand and fixation processing is reviewed. The limitations of these conventional practices with respect to treated product quality and CCA solution handling issues are defined. A novel, patented treatment schedule has been developed using a combination of hydraulic and pneumatic pressure phases and hot (~ 75°C) CCA solutio...
K Nasheri, A J Pendlebury, J A Drysdale, H Pearson, M E Hedley


Chemical Analysis of Southern Pine Pole Stubs Thirteen Months Following Treatment with Three Methylisothiocyanate Based Commercial Fumigants
2002 - IRG/WP 02-30294
Agricultural fumigants have been commercially used in the United States for over 20 years to control internal decay in utility poles and other wooden structures. Of the four fumigants which are currently used in the remedial treatment of utility poles, three are based on methylisothiocyanate (MITC) as being the principal fungitoxic component. Two of these MITC based fumigants, liquid metham sodi...
R J Ziobro, T C Anderson, D J Herdman, J Guzzetta, T Pope


A laboratory evaluation of tributyltin ethanesulphonate as an aqueous fungicide in wood preservation
1983 - IRG/WP 3229
Toxic limit data, using both leached and unleached wood test blocks, are reported for aqueous solutions of tributyltin ethanesulphonate against four Basidiomycete fungi, Poria placenta, Gloeophyllum trabeum, Coriolus versicolor and Coniophora puteana. An in situ study of the tributyltin compound in Scots pine and ponderosa pine sapwood has been carried out, using the technique of 119mSn Mössbauer...
R Hill, P J Smith, J N R Ruddick, K W Sweatman


Evaluation of the efficiency of industrial kiln type CCA fixation chambers
1996 - IRG/WP 96-40063
Six commercial CCA treating plants in Canada were assessed for the fixation efficiency of their hot air fixation chambers. The wood temperature was measured with thermocouples over the fixation period at different locations in the chamber and at the end of the fixation cycle, the degree of chromium fixation was determined by a boring leaching procedure. There was a great variation in the effective...
A Taylor, P A Cooper


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Comments on leaching in view of accelerated testing
1977 - IRG/WP 294
We developed an accelerated test for leaching at elevated temperatures (75-85°C). This test was used for the examination of 11 preservative formulations containing Cu, Zn and As. The data obtained from these experiments were compared with data on some formulations tested by ASTM standard leaching test. The method consists in making a large surface to volume ratio of wood from a treated block by c...
J Rak


Enzymatic study of Ceratocystis sp., blue-stain fungi on Pinus nigra
1999 - IRG/WP 99-10315
One of the main problems that the forest exploitation industry has with Pinus nigra wood is the blue-stain fungi, whose causing agent is unknown. Therefore, the objective of this work has been to study, through enzymatic tests of the isolated cultures, if these fungi infect Pinus nigra in any specific way. After the incubations, isolates of Ceratocystis were obtained. These were cultured in a sali...
M T De Troya, F Rubio, D Muñoz-Mingarro, F Llinares, C Rodríguez-Borrajo, M Yuste, M J Pozuelo, J I Fernández-Golfín


Detection of increased metal cations after wood decay using Chromeazurol-S
1997 - IRG/WP 97-20112
Chromeazurol-S (CAS) is a dye used for the spectrophotometric determination of metals, mainly aluminum (Al), berillium (Be) and copper (Cu). CAS has been widely used for determining the penetration of copper containing preservatives like CCA (AWPA A3-96). Additional uses include: i) detection of utility pole decay (Esyln, 1979), ii) a chemical spot test for aluminum in wood (Kukachka and Miller, 1...
F Green III, U Srinivasan, R B Miller


Field study: Wood degradation pattern in buildings and utility poles in tropical climates of Nigeria
1992 - IRG/WP 92-1521
The paper is the result of five years field study of wood degradation patterns in three ecological forest zones (Guinea Savannah, Tropical rain forest and mangrove forest zones, respectively). It involved 800 residential buildings and 700 electric overhead transmission poles. The methodology used was a modified Eslyn (6) test. A high rate of Ascomycetes and Basidiomycetes attack especially on the ...
E O Onuorah


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


Effect of test site location on in-ground preservative performance after 6 years
2001 - IRG/WP 01-20231
Pinus radiata test stakes were treated with 4.1 kg/m3 of CCA and Fagus sylvatica with 6.1 kg/m3 of CCA. Both wood species were also treated with a copper plus triazole preservative (3 kg/m3 of copper) and chlorothalonil plus chlorpyriphos in oil (4.8 kg/m3 chlorothalonil). Furthermore, P. radiata was treated with ammoniacal copper plus a quaternary ammonium compound (2.6 kg/m3 copper) and a 60/40 ...
R N Wakeling


IRG/COIPM INTERNATIONAL MARINE TEST - to determine the effect of timber substrate on the effectiveness of water-borne salt preservatives in sea-water. Progress Report 11: Report of fourth inspection (3 years) in Italy
1981 - IRG/WP 471
The wood samples of Alstonia scholaris, Fagus sylvatica, Pinus sylvestris were submerged in the sea at Follonica, Italy, in Apri1 1977. Follonica, latitude 42°55' North and longitude 10°45' East, is situated on the Tyrrhenian coast. The recorded temperature varies from 13°C td 25°C, salinity 37- 38%. and pH about 8. The inspections were carried out after 6 months (10/1977), 1...
A Gambetta, E Orlandi


A method test of chemicals for the treatment of walls infected with Serpula lacrymans
1992 - IRG/WP 92-2408
A method, which has been used in the UK for over 25 years, is described for assessing the effectiveness of products for application to walls during remedial treatment to eradicate the dry rot fungus Serpula lacrymans. Approvals for products previously used for this purpose in the UK are being changed. Approval for tri n-butyltin oxide has been withdrawn, and PCP derivatives can continue to be used...
J K Carey


Possible durability transfer from durable to non durable wood species. The study case of teak wood
2001 - IRG/WP 01-10392
Teakwood is well known for its excellent natural durability, mostly due to its high proportion of extracts. Amongst these extracts, quinones, and more precisely some naphtoquinones (such as lapachol) and anthraquinones (such as tectoquinone) appear to play a crucial role in the resistance to wood decay organisms. At a laboratory scale, sawdust from malaysian teak heartwood has been extracted under...
M-F Thévenon, C Roussel, J-P Haluk


Comparison of the anti-fungal efficacy of Cobra with drill perforation on oscillating pressure treated spruce transmission poles -Laboratory test
1988 - IRG/WP 3469
A laboratory method for measuring the depth of penetration of the fungicidal concentrations effective against basidiomycetes (brown rot) was developed. The tests on CCB oscillating pressure treated spruce transmission poles have shown that the depth of salt penetration can be increased by about 10 mm by a drill perforation before the impregnation. An even better penetration is reached, however, if...
E Graf, B Zgraggen


Methods for the assessment of wood preservative movement in soil
1995 - IRG/WP 95-50040-08
This paper presents preliminary results from a series of experiments constructed to provide laboratory data for the evaluation of the leaching of wood preservatives into and through soil. The experiments included: i) measurement of the adsorption of preservatives by soil; ii) determination of the concentration gradient of preservatives in soil following percolation of preservative solution through...
G E Holland, R J Orsler


Previous Page | Next Page