Damage by wood-attacking insects in buildings in Sao Paulo State - Brazil. (including errata slip)
1978 - IRG/WP 175
From 1974 to 1978 up to 602 buildings attacked by wood-boring insects were inspected by Instituto de Pesquisas Tecnologicas in Sao Paulo State - Brazil. Damage was caused mainly by subterranean termites, dry-wood termites and wood-attacking beetles. Up to US $ 1000,000 is the amount needed to control such insects in the buildings inspected...
A T De Lelis


Fipronil - le nouvel insecticide de Rhone Poulenc pour la preservation du bois
1995 - IRG/WP 95-30078
After the 3rd International Symposium in Cannes '95. More trial results and practical information on FIPRONIL, this new insecticide from Rhone Poulenc for Wood Preservation and PCO....
M G E J Van Maanen


Minutes of the Meeting of WG I 1970
1970 - IRG/WP 16
IRG Secretariat


Minutes of the WG IV meeting 1975
1975 - IRG/WP 413
IRG Secretariat


Biocontrol and bioprotection of wood decay and sapstain fungi
2003 - IRG/WP 03-10474
The most serious damages caused in the wood industries by decay and sapstain fungi, and the growing international pressures on the use of biocides products with toxic active ingredients harmful to human health and the environment, have made it necessary to search for alternative chemical products to protect the wood, and for the possibility to use micro-organisms as biological controllers. This la...
M T De Troya, F Rubio, M Villarreal, F Arenal, F Llinares, V Rubio, D Muñoz-Mingarro, N Acero


Effect of treatment process on performance of copper-chrome-arsenate. Part 2: Field stake tests
1995 - IRG/WP 95-40046
Pinus radiata sapwood stakes 20 x 20 x 400 mm³ were treated with CCA Type C using a range of concentrations and three treatment processes; Bethell, Lowry and Rueping. Preservative retention was determined by chemical analysis of treated material. Following fixation stakes were installed in a randomised plot in the Whaka graveyard located on the FRI campus. Stakes were inspected at yearly interval...
M E Hedley, J Anderson, J B Foster, B E Patterson


Summarized comparison of four techniques for detecting defects in poles
1979 - IRG/WP 2126
Since our discussions in open session of Working Group II at Peebles, a number of workers in Australia have collaborated in comparing the efficacy of X-ray, sonic testing, or resistivity measurements for detecting internal defects in poles. The purpose of this circular is to draw to your attention some of the results, in summary form. No attempt has been made to compare techniques. More detailed a...
H Greaves


IRG 25 invitation
1994 -
IRG Secretariat


Budget for 2003
2002 - IRG/WP 02-60157
IRG Secretariat


Budget (revised) for 1994
1994 - IRG/WP 94-60035
IRG Secretariat


End grain sealants for wood preservation studies
1985 - IRG/WP 3341
The results of tests with possible end grain sealants for wood preservation studies are reported. The epoxy resins used gave satisfactory performance on wet or dry Sitka spruce and have been used with success for diffusion treatment studies....
R J Murphy, N A Summers


Calculation of preformance index of Bardac 20 (an alkylammonium compound) evaluated in a field stake test
1982 - IRG/WP 3206
Bardac 20 treated stakes have been in test for three years at the Westham Island test site near Vancouver, B.C. The Performance Index for the preservative was calculated and found to be 0.009 which infers that, at the standard retention, Bardac 20 added 0.9 y to the life of the stake. It may be concluded that when tested using a standard field stake test using ponderosa pine (Pinus ponderosa Laws)...
J N R Ruddick


Preliminary study on relation of wood structure to copper/chrome/arsenic (CCA) distribution in kempas (Koompassia malaccensis)
1995 - IRG/WP 95-40054
Kempas had been treated with copper/chrome/arsenic (CCA) preservative using full cell process. Analysis of preservative distribution at the micro level in relation to wood structure was carried out using scanning electron microscope (SEM) and energy dispersive X-ray (EDXA) analysis. The results showed that CCA elements were detected in all wood tissues at different ratios. Distribution of chemical...
S Ani, S Salamah


Correlation between different international standard assessment procedures with termites. Part 1: Field exposure
1983 - IRG/WP 1198
Ramin treated with copper-chrome-arsenic (CCA), pentachlorophenate and lindane, each at three retentions, and three other untreated timbers were assessed in the field against Coptotermes lacteus and Nasutitermes exitiosus. Replicate specimens were exposed around five mounds of each termite species over a period of five years in south-eastern Australia. The field results provided the basis for judg...
M Lenz, C D Howick, N Tamblyn, J W Creffield, M Westcott


Natural durability of Iranian saxual wood (Haloxylon persicum) against the fungal decay
1991 - IRG/WP 1515
Haloxylon persicum is vidly planted in the deserfic region of Iran. At the present time, in the age of 30, these small trees are ready for cutting for the different uses, specially for rural buildings. But there's any knowledge about its durability. In this study the laboratory tests were carried out in accordance to European Standard. 5 fungi were used as: Trametes versicolor, Coniophora...
D Parsapajouh, F H Schweingruber, K Richter


Acceleration of the fixation of chromated wood preservatives by UV-radiation
1989 - IRG/WP 3544
Preliminary laboratory tests demonstrated that the fixation of chromated water-borne wood preservatives may be accelerated by UV-radiation. The degree of fixation depends on the intensity of radiation and the prevailing temperature. Three hours radiation at 20°C in a device for artificial weathering diminished the leaching of chromium to 43% and of copper to 23% compared to not-radiated samples. ...
H M Illner, H Willeitner, K Brandt


Status of the Working Group on Preservation of Wood in the Marine Environment - Questionnaire results
1977 - IRG/WP 434
At the joint meeting of the IRG and COIPM dealing with preservation of wood in the marine environment, it was suggested that a Marine Group should be formally recognised within IRG. It was agreed that a questionnaire (Document No: IRG/WP/424) should be circulated to determine the views of the membership on the future status of this group. The results of this questionnaire are presented....
R A Eaton


A simple non-destructive means of testing poles in situ
1982 - IRG/WP 2167
Anonymous


Minutes of the meetings of WG III
1990 - IRG/WP 3638
IRG Secretariat


Reporting minutes of the Plenary Meeting 2000
2000 - IRG/WP 00-60132
IRG Secretariat


A Preliminary Report on the Properties of Engineered Wood Composite Panels Treated with Copper Naphthenate
2005 - IRG/WP 05-40294
This paper reports on our preliminary investigation of the properties of randomly oriented strandboard which had waterborne or powdered copper naphthenate (CuN) incorporated into the board during manufacture. When compared to zinc borate-treated controls (ZnB), the mechanical properties of strandboard (MOR, MOE, work-to-maximum load, internal bond strength) were not adversely affected by treatmen...
J W Kirkpatrick, H M Barnes


Leachability And Decay Resistance of Copper-Treated Wood
2004 - IRG/WP 04-30337
Samples of scots pine sapwood (Pinus sylvestris L.) were treated with solutions of (Copper II sulfat-5 hydro + fluoroboric acid) and (Copper II sulfat-5 hydro + fluoroboric acid + boric acid) in order to determining to leachability and decay resistance against brown rot fungus (Postia placenta) and white rot fungus (Coriolus versicolor). Results indicated that the copper in treated wood is less s...
A Temiz, T Nilsson, I Deemirtas, Ü C Yildiz


Sampling variation in a copper chrome arsenic treated power transmission pole
1990 - IRG/WP 2351
The Queensland Forest Service routinely samples poles treated at all treatment plants throughout the State. Each treatment plant is issued with a Certificate of Registration and the accompanying documents list the different levels of preservative retention required for performance in various service conditions. The posted levels represent the.minimum permissible, and it is to these concentrations ...
J Norton


Leaching results of shower test on L-joints with boric acid, bifluoride and TBTO rods
1995 - IRG/WP 95-50051
As part of the EC-project "Improvement of a local preservation process for wood products with reduced environmental impact", TNO has performed a leaching test on L-joints treated with pills with boric acid (Defence corner), bifluorides (Woodpil 55) and TBTO (Woodcap). The L-joints were exposed in an adapted shower test during 10 days, using 70 liters of water per day. The experiment is designed to...
P Esser, M J Boonstra, W L D Suitela, A J Pendlebury


Antagonism to spore germination in Scots pine
1990 - IRG/WP 1458
Germination of Lenzites trabea and Chaetomium globosum spores was observed directly on wood blocks, on water soluble extracts and on organic solvent soluble extracts from pine wood. In all cases pine heartwood was found to be antagonistic to spore germination but pine sapwood varied in its antagonism according to the method of drying. Chromatography revealed that extracts from antagonistic wood di...
S M Gray